02 / Brass cable entry
Brass Cable Glands
Brass cable glands secure cables to metal cabinets and equipment. The range includes compact straight entries, angled exits, longer threads for thicker walls, and separate EMC and armoured constructions.
- Cable and seal range
- Thread designation
- Material and bonding duty
Cable gland families
Compare cable glands by material, cable construction and duty.
Choose nylon, brass or stainless steel by body material, or compare EMC, armoured, hazardous-area, marine and conduit-entry designs by the job they must perform.
Brass Cable Glands range
Choose your brass cable glands
Metal cable glands with standard, angled, long-thread, multi-hole and bend-protection forms.
Models & dimensions
Brass Cable Glands: specifications and dimensions
Select a product to see its specifications, drawings and sizes.
Brass Cable Glands
Which fitting do you need?
Choose a product above, or show all products to compare sizes and construction.- 01Cable and seal range
- 02Entry thread and dimensions
- 03Material and installation duty
Brass Cable Gland — Metric, PG, G and NPT
01 / Brass cable entry
Brass Cable Gland — Metric, PG, G and NPT
Nickel-plated brass cable glands with a polyamide clamping insert and EPDM or silicone sealing parts.
Product reference
- Construction
- Standard Brass Cable Glands
- Application
- A cable entry needs a nickel-plated brass body with an EPDM or silicone seal.
Key specifications
- Body Material
- Nickel-Plated Brass
- Clamping Insert
- Nylon PA66
- Seal & O-Ring
- EPDM or silicone rubber
- Protection Class
- IP68 – 10 Bar
Product specifications
Construction and details

Assembly arrangement and dimensions
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Model specification tablesFurther specifications
- Operating Temperature (Static)
- -40°C to 100°C (short term to 120°C)
- Operating Temperature (Dynamic)
- -20°C to 80°C (short term to 100°C)
- Thread Types
- M, PG, G, NPT
- Color
- Metallic Silver
- NPT locknut
- Supplied without a locknut as standard; optional locknut available.
- Claw material flammability
- UL 94 V-2 (PA66)
Key features
- Nickel-plated brass bodyThe metal body is paired with a polyamide clamping insert.
- EPDM or silicone sealsEPDM or silicone components seal around the cable and at the enclosure entry.
- Metric, PG, G and NPTFour thread systems cover different enclosure-entry connections.
90-Degree Brass Fitting for Flexible Conduit
02 / Brass cable entry
90-Degree Brass Fitting for Flexible Conduit
A nickel-plated brass elbow fitting for flexible metallic or liquid-tight conduit where the run must turn through 90 degrees.
Product reference
- Construction
- Right-Angle Brass Glands
- Application
- A conduit run needs a right-angle connection close to the enclosure.
Key specifications
- Product Name
- 90-degree brass conduit fitting
- Body Material
- Nickel-Plated Brass
- Operating Temperature
- -40°C to 100°C (up to 120°C for short periods)
- Thread Types
- Metric (Standard), PG & G (Available on request)
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Application
- Flexible metallic conduits, liquid-tight conduits
Key features
- 90-degree bodyThe elbow turns the conduit away from a straight-out route.
- Metal conduit connectionThe fitting is intended for flexible metallic and liquid-tight conduit.
- Thread optionsMetric versions are standard, with PG and G options available on request.
Extended-Thread Metal Cable Gland for Thick Panels
03 / Brass cable entry
Extended-Thread Metal Cable Gland for Thick Panels
A metal cable gland with an extended entry thread for thick panels and deeper threaded mounting points.
Product reference
- Construction
- Extended-Thread Brass Glands
- Application
- A standard-length gland does not leave enough usable thread for the panel, washer and locknut.
Key specifications
- Product Name
- Extended Thread Brass Cable Gland
- Body Material
- Nickel-Plated Brass (Stainless Steel 304/316L available)
- Claw
- Nylon PA66
- Seal & O-Ring
- EPDM or silicone rubber
Product specifications
Construction and details

Assembly arrangement and dimensions
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Model specification tablesFurther specifications
- Protection Rating
- IP68, 10 bar
- Operating Temperature
- Static: −40°C to +100°C; short term to +120°C
- Thread Types
- Metric (Standard), PG, NPT, G (Available)
- Dynamic temperature
- −20°C to +80°C; short term to +100°C
- Claw material flammability
- UL 94 V-2 (PA66)
Key features
- Long entry threadThe extended male thread provides additional mounting length.
- PA clamping clawA polyamide claw retains the cable within the gland.
- EPDM or silicone sealsThe seal and O-ring are EPDM or silicone rubber.
Brass Cable Gland with Silicone Seals
04 / Brass cable entry
Brass Cable Gland with Silicone Seals
A nickel-plated brass cable gland with silicone sealing parts.Product reference
- Construction
- Standard Brass Cable Glands
- Application
- A cable entry requires a silicone seal and O-ring.
Key specifications
- Product Name
- Brass cable gland with silicone seals
- Body Material
- Nickel-Plated Brass
- Seal & O-Ring
- Silicone Rubber
- Protection Rating
- IP68
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Standard Sizes
- M8 to M63
- M18-SI / M20-SI static temperature
- −60°C to +250°C (silicone seals)
- M18-SI / M20-SI ingress protection
- IP68, 10 bar
Key features
- Silicone seal and O-ringThe cable seal and O-ring use silicone rubber.
- Metal bodyThe nickel-plated brass body retains the straight cable-entry form.
- Metric size rangeThe range includes M8 through M63 models.
Multi-Hole Brass Cable Gland for 2–8 Cables
05 / Brass cable entry
Multi-Hole Brass Cable Gland for 2–8 Cables
A nickel-plated brass cable gland with a sealing insert containing two to eight holes for separate cables.
Product reference
- Construction
- Multi-Hole Brass Glands
- Application
- Two to eight small cables need to pass through one metal gland body.
Key specifications
- Product Name
- Multi-Hole Brass Cable Gland
- Body Material
- Nickel-Plated Brass
- Claw
- Polyamide (PA)
- Seal & O-Ring
- NBR
Product specifications
Construction and details
Further specifications
- Hole Variants
- 2 to 8 holes (customization available)
- Protection Rating
- IP68 – 10 Bar
- Operating Temperature (Static)
- -40°C to 100°C (short term to 120°C)
- Thread Types
- Metric, PG, G, NPT
Key features
- Two to eight holesInsert options provide separate bores for individual cables.
- Metal body and PA clawA nickel-plated brass body and polyamide claw hold the multi-hole sealing arrangement.
- NBR sealThe insert uses NBR to seal around the individual cable jackets.
Brass Cable Gland with Flexible Bend Guard
06 / Brass cable entry
Brass Cable Gland with Flexible Bend Guard
A nickel-plated brass cable gland with a spring bend guard to support the cable near the enclosure entry.
Product reference
- Construction
- Anti-Bending Brass Glands
- Application
- A metal gland needs a flexible tail to guide the cable away from the entry.
Key specifications
- Product Name
- Flexible Bend Protection Cable Gland
- Body Material
- Nickel-Plated Brass
- Flexible Guard
- Spring bend guard
- Liner
- Insulating Liner
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: d · H · GL · AG
Model specification tablesFurther specifications
- Protection Rating
- IP68, 10 bar
- Thread Types
- Metric and PG
- Claw Material
- Nylon PA66
- Seal Material
- EPDM or silicone rubber
- Operating temperature
- −40°C to +100°C; short term to +120°C
- Claw material flammability
- UL 94 V-2 (PA66)
Key features
- Spring bend guardA metal spring extends from the gland to support the cable where it leaves the seal.
- Metal entry bodyThe nickel-plated brass body provides the enclosure connection.
- Metric and PG threadsChoose the entry thread and cable sealing range from the model table.
Double-Locked Brass Cable Gland
07 / Brass cable entry
Double-Locked Brass Cable Gland
A brass cable gland with a dual-clamping construction for retaining the cable at the enclosure entry.
Product reference
- Construction
- Double-Lock Brass Glands
- Application
- The cable installation calls for a dual-clamping gland construction.
Key specifications
- Product Name
- Double-Locked Brass Cable Gland
- Body Material
- Nickel-Plated Brass
- Clamp Jaw
- Nylon PA66
- Sealing Element
- EPDM or silicone rubber
Product specifications
Construction and details

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL · H
Model specification tablesFurther specifications
- Protection Class
- IP68, 10 bar
- Operating Temperature
- Static: −40°C to +100°C; short term to +120°C
- Thread Types
- Metric; PG, G and NPT available to order.
- Dynamic temperature
- −20°C to +80°C; short term to +100°C
- Claw material flammability
- UL 94 V-2 (PA66)
Key features
- Dual-clamping arrangementThe double-locked design uses an additional cable-retention arrangement within the gland.
- Polyamide clamp jawA PA jaw forms part of the cable-clamping assembly.
- Seal choicesEPDM or silicone is the standard sealing element, with silicone and EPDM available on request.
BR-Series Breathable Brass Cable Gland
08 / Brass cable entry
BR-Series Breathable Brass Cable Gland
A BR-series brass cable gland combining a cable-entry connection with a venting function.
Product reference
- Construction
- Special Brass Gland Series
- Application
- An enclosure design calls for a venting gland at the cable entry.
Key specifications
- Body material
- Brass
- Model series
- BR
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: H · GL · AG
Model specification tablesKey features
- Cable entry with ventingThe breathable construction adds a venting function to the cable-entry fitting.
- Brass bodyA brass body provides the threaded connection to the enclosure.
MG-Series Brass Cable Gland
09 / Brass cable entry
MG-Series Brass Cable Gland
An MG-series metal cable gland with a PA66 claw and EPDM or silicone sealing parts, available in four enclosure-thread systems.
Product reference
- Construction
- Standard Brass Cable Glands
- Application
- A straight metal cable entry calls for the MG construction.
Key specifications
- Product Series
- MG Series
- Body Material (Parts A, C, F)
- Nickel-Plated Brass
- Claw (Part E)
- Nylon (PA66)
- Seal & O-Ring (Parts B, D)
- EPDM or silicone rubber
Product specifications
Construction and details
Further specifications
- Protection Rating
- IP68 – 10 Bar
- Static Temperature
- -40°C to 100°C (short term to 120°C)
- Dynamic Temperature
- -20°C to 80°C (short term to 100°C)
- Thread Types
- Metric, PG, G(PF/BSP), NPT
- Claw material flammability
- UL 94 V-2 (PA66)
Key features
- EPDM or silicone sealsThe seal and O-ring are available in EPDM or silicone rubber.
- PA66 clawThe nylon claw clamps the cable inside the metal body.
- Four thread systemsMetric, PG, G and NPT versions are included in the MG range.
Straight-Through Brass Cable Gland — Standard and Long Thread
10 / Brass cable entry
Straight-Through Brass Cable Gland — Standard and Long Thread
A straight-through brass cable gland with EPDM or silicone sealing parts and standard or long entry-thread options.
Product reference
- Construction
- Standard Brass Cable Glands
- Application
- A straight cable entry needs a choice of mounting-thread length for a thin or thick panel.
Key specifications
- Product Name
- Straight-Through Brass Cable Gland
- Body Material
- Nickel-Plated Brass
- Claw
- Nylon PA66
- Seal & O-Ring
- EPDM or silicone rubber
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Protection Rating
- IP68 – 10 Bar
- Static Temperature
- -40°C to 100°C (short term to 120°C)
- Dynamic Temperature
- -20°C to 80°C (short term to 100°C)
- Thread Length
- Standard (for thin boards), Long (for thick boards)
- Thread systems
- Metric and PG; G and NPT available to order.
- Claw material flammability
- UL 94 V-2 (PA66)
Key features
- Straight cable pathThe cable passes through the gland along the entry axis.
- Two thread lengthsStandard and long entry-thread versions address different panel arrangements.
- PA66 claw and elastomer sealsA nylon PA66 claw retains the cable; EPDM or silicone parts seal the assembly.
90-Degree Brass Conduit Fitting
11 / Brass cable entry
90-Degree Brass Conduit Fitting
A nickel-plated brass conduit fitting with a 90-degree body and polyamide internal components for flexible metallic conduit.
Product reference
- Construction
- Right-Angle Brass Glands
- Application
- A flexible metallic or liquid-tight conduit must turn at the equipment entry.
Key specifications
- Product Name
- 90 Degree Elbow Conduit Fitting
- Body Material
- Nickel-Plated Brass
- Internal Components
- Nylon (PA)
- Protection Rating
- IP68
Product specifications
Construction and details
Further specifications
- Operating Temperature
- -40°C to 100°C (short term up to 120°C)
- Application
- Flexible Metallic Conduit, Liquid Tight Conduit
Key features
- Right-angle conduit pathThe elbow turns the conduit connection through 90 degrees.
- Metal body with PA partsThe fitting combines nickel-plated brass with nylon internal components.
M-NW Female-Thread Cable Gland for Threaded Conduit
12 / Brass cable entry
M-NW Female-Thread Cable Gland for Threaded Conduit
An M-NW-series metal cable gland with a female-thread connection for a threaded conduit or mating entry.
Product reference
- Construction
- Special Brass Gland Series
- Application
- A cable gland must join a male-threaded conduit or fitting through an internal-thread connection.
Key specifications
- Product Type
- Female Thread Cable Gland / Conduit to Cable Fitting
- Body Material
- Nickel-Plated Brass, Stainless Steel (304/316L)
- Claw
- Nylon (PA)
- Seal & O-Ring
- NBR
Product specifications
Construction and details
Further specifications
- Protection Rating
- IP68 – 10 Bar
- Static Temperature
- -40°C to 100°C (short term to 120°C)
- Dynamic Temperature
- -20°C to 80°C (short term to 100°C)
- Thread Types
- Female-thread connection; thread standard and size depend on the model
Key features
- Female-thread connectionThe internal thread connects to a male-threaded mating part.
- M-NW model codesThe M-NW dimension series identifies the model and cable sealing range.
- NBR sealing partsThe construction combines an NBR seal and O-ring with a nylon claw.
M-NLW Internal-Thread Cable Gland
13 / Brass cable entry
M-NLW Internal-Thread Cable Gland
An M-NLW-series metal cable gland with an internal thread for connection to a male-threaded entry.
Product reference
- Construction
- Special Brass Gland Series
- Application
- The equipment or adjoining fitting presents a male thread that needs a female-thread cable gland.
Key specifications
- Product Type
- Female Thread / Internal Thread Cable Gland
- Body Material
- Nickel-Plated Brass, Stainless Steel (304/316L)
- Claw
- Nylon (PA)
- Seal & O-Ring
- NBR (Nitrile Rubber)
Product specifications
Construction and details
Further specifications
- Protection Rating
- IP68 – 10 Bar
- Static Temperature
- -40°C to 100°C (short term to 120°C)
- Dynamic Temperature
- -20°C to 80°C (short term to 100°C)
- Thread Types
- Metric, PG, G, NPT (Internal/Female Thread)
Key features
- Internal entry threadThe gland connects to a male-threaded mating entry.
- M-NLW dimension seriesM-NLW codes identify this construction and its cable-range options.
- NBR seal and O-ringNitrile-rubber sealing parts work with the nylon clamping claw.
M-LBK Double-Flare Cable Gland
14 / Brass cable entry
M-LBK Double-Flare Cable Gland
An M-LBK-series metal cable gland with a double-flare cable-entry shape and NBR/PA6 sealing components.
Product reference
- Construction
- Special Brass Gland Series
- Application
- The installation drawing calls for the double-flare M-LBK construction.
Key specifications
- Design
- Double Flare / Double Trumpet Mouth
- Body Material
- Nickel-Plated Brass, Stainless Steel (304, 316)
- Seal Material
- NBR (Nitrile Rubber), PA6 Nylon
- Protection Rating
- IP68 – 10 Bar
Product specifications
Construction and details
Further specifications
- Static Temperature
- -40°C to 100°C (short term to 120°C)
- Dynamic Temperature
- -20°C to 80°C (short term to 100°C)
Key features
- Double-flare shapeThe construction uses a double trumpet-mouth form at the cable entry.
- Metal body optionsThe range includes nickel-plated brass and stainless-steel body options.
- M-LBK model codesThe model schedule links the M-LBK code to thread, cable range and fitting dimensions.
MG-Series EMC Cable Gland
15 / Brass cable entry
MG-Series EMC Cable Gland
An MG-series EMC cable gland that combines cable clamping and sealing with contact to the cable screen.
Product reference
- Construction
- Brass EMC Cable Glands
- Application
- A screened cable enters an enclosure and its screen needs a connection through an MG gland.
Key specifications
- Product Type
- MG Series EMC Shielding Cable Gland
- Body Material
- Nickel-Plated Brass, Stainless Steel (304, 316L)
- Claw
- Nylon (PA66)
- Seal & O-Ring
- EPDM Rubber (Custom options available)
Product specifications
Construction and details

Shield-contact assembly
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Confirm the mating interface, contact arrangement and mounting dimensions for the selected model.
Further specifications
- Protection Rating
- IP68 – 10 Bar
- Static Temperature
- -40°C to 100°C (short term to 120°C)
- Dynamic Temperature
- -20°C to 80°C (short term to 100°C)
- Thread Types
- Metric, PG, G(PF/BSP), NPT
- Function
- Cable-screen contact and cable retention
- Seals for E.M25A-EMC / E.M32B-EMC
- EPDM or silicone rubber
- E.M25A-EMC / E.M32B-EMC claw flammability
- UL 94 V-2 (PA66)
Key features
- Screen contactThe gland includes a path for contacting the cable braid or screen at the entry.
- EPDM sealing partsThe MG EMC construction uses an EPDM seal and O-ring with a PA66 claw.
- Metal body choicesNickel-plated brass and stainless-steel versions are available.
Spring-Contact EMC Cable Gland
16 / Brass cable entry
Spring-Contact EMC Cable Gland
An EMC cable gland with a contact spring that connects the cable screen to the metal gland body.
Product reference
- Construction
- Brass EMC Cable Glands
- Application
- A screened cable needs a spring-contact termination at the enclosure entry.
Key specifications
- Product Type
- Spring-Type EMC Shielding Cable Gland
- Body & Nut Material
- Nickel-Plated Brass, Stainless Steel (304, 316)
- Contact Spring
- Conductive spring; material depends on the model
- Clamping Insert
- Polyamide (PA6 V2)
Product specifications
Construction and details
Further specifications
- Seal & O-Ring
- NBR (Nitrile Rubber)
- Protection Rating
- IP68 – 5 Bar
- Operating Temperature
- -40°C to +100°C (short term to +120°C)
- Thread Types
- Metric (EN 60423), PG
- Function
- Cable-screen contact
Key features
- Contact springA conductive spring forms the screen-contact element.
- NBR sealing partsThe seal and O-ring are NBR, with a PA6 clamping insert.
- Metric and PG entriesThe range includes Metric and PG enclosure threads.
D-Series EMC Cable Gland
17 / Brass cable entry
D-Series EMC Cable Gland
A D-series EMC cable gland with a metal body, polyamide claw and NBR sealing parts for screened cable entries.
Product reference
- Construction
- Brass EMC Cable Glands
- Application
- Connect a cable screen at the enclosure entry with an NBR seal around the cable jacket.
Key specifications
- Product Series
- D Series EMC Cable Gland
- Body Material
- Nickel-Plated Brass, Stainless Steel (304, 316L)
- Claw
- Nylon (PA)
- Seal & O-Ring
- NBR (Nitrile Rubber) (Custom options available)
Product specifications
Construction and details

Shield-contact assembly
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Confirm the mating interface, contact arrangement and mounting dimensions for the selected model.
Further specifications
- Protection Rating
- IP68 – 10 Bar
- Static Temperature
- -40°C to 100°C (short term to 120°C)
- Dynamic Temperature
- -20°C to 80°C (short term to 100°C)
- Function
- Cable-screen contact and cable retention
Key features
- D-series constructionThe D-series gland combines screen contact with cable clamping at the enclosure entry.
- NBR sealing partsThe standard seal and O-ring are NBR, with other seal options available for some models.
- Metal body optionsThe range includes nickel-plated brass and stainless-steel bodies.
F-Series EMC Cable Gland for Metric Entries
18 / Brass cable entry
F-Series EMC Cable Gland for Metric Entries
An F-series EMC cable gland with a metal body, nylon fastening parts and an NBR seal for Metric entries.
Product reference
- Construction
- Brass EMC Cable Glands
- Application
- A screened-cable installation calls for an F-series gland with a Metric enclosure thread.
Key specifications
- Product Series
- F Series EMC Cable Gland
- Body & Nut Material
- Nickel-Plated Brass or Stainless Steel
- Fastener
- Nylon / Plastic
- Seal & O-Ring
- NBR (Nitrile Rubber)
Product specifications
Construction and details
Further specifications
- Protection Rating
- IP68 – 10 Bar
- Operating Temperature
- -40°C to +100°C (short term to 120°C)
- Thread Type
- Metric
- Function
- Cable-screen contact and cable retention
Key features
- Metric entryThis F-series construction uses a Metric threaded connection.
- Metal body and nylon partsThe body is brass or stainless steel with nylon fastening components.
- NBR sealing partsNitrile rubber forms the seal and O-ring around the cable-entry assembly.
BW Cable Gland for Indoor SWA Cable
19 / Brass cable entry
BW Cable Gland for Indoor SWA Cable
A BW two-part brass gland that locks steel-wire armour at an indoor, dry cable entry.
Product reference
- Construction
- Brass Armoured Cable Glands
- Application
- An SWA cable requires a BW armour-lock construction for an indoor, dry location.
Key specifications
- Gland Type
- BW 2-Part Armour Lock
- Application
- Indoor & Dry locations, for SWA (Steel Wire Armour) Cable
- Material
- Brass (Optional Nickel Plating)
- Protection Rating
- IP30
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Thread Options
- Metric, NPT, BSP, PG
- Accessories
- Locknut, Earth Tag, PVC Shroud
Key features
- Two-part armour lockThe BW construction mechanically retains the steel-wire armour.
- Indoor, dry applicationThe BW form is intended for indoor and dry locations.
- Accessory optionsLocknuts, earth tags and PVC shrouds are available for the installation.
CW Single-Compression Cable Gland for SWA
20 / Brass cable entry
CW Single-Compression Cable Gland for SWA
A CW single-compression brass cable gland for steel-wire-armoured cable, with sealing and armour retention at the entry.
Product reference
- Construction
- Brass Armoured Cable Glands
- Application
- An SWA cable installation requires a CW single-compression sealing construction.
Key specifications
- Gland Type
- CW Single Compression
- Application
- Steel-wire-armoured cable entries
- Material
- Brass (Optional Nickel Plating)
- Protection Rating
- IP66 / IP67
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Operating Temperature
- -20°C to +80°C
- Thread Options
- Metric, NPT, BSP, PG
- Accessories
- Locknut, Earth Tag, PVC Shroud
Key features
- Single-compression formThe CW construction combines an armour-retention arrangement with a cable seal.
- Brass bodyThe body is brass, with nickel plating available as an option.
- Installation accessoriesThe range includes locknuts, earth tags and PVC shrouds.
Ex-VII Double-Seal Armoured Cable Gland
21 / Brass cable entry
Ex-VII Double-Seal Armoured Cable Gland
An Ex-VII metal cable gland with double sealing and an armour-clamping arrangement for wire-, braid- or tape-armoured cable.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- An armoured cable requires the Ex-VII double-seal construction.
Key specifications
- Product Type
- Double-seal armoured cable gland
- Model
- Ex-VII d/e BDM
- Body Material
- Nickel-plated brass, SS304 stainless steel, or SS316 stainless steel
- Seal Material
- Silicone Rubber
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
- Applicable Cable
- Steel Wire, Braided, and Steel Tape Armoured Cables
Key features
- Double sealingThe Ex-VII construction incorporates two sealing stages with armour clamping.
- Silicone sealsThe gland uses silicone sealing parts within a nickel-plated brass body.
- Armoured-cable formsThe construction covers steel-wire, braided and steel-tape armour arrangements.
Ex-B Cable Gland for Unarmoured Cable
22 / Brass cable entry
Ex-B Cable Gland for Unarmoured Cable
An Ex-B metal cable gland for unarmoured cable, with NBR, PTFE or silicone sealing options.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- An unarmoured cable entry calls for the Ex-B construction and a specified seal material.
Key specifications
- Product Type
- Cable gland for unarmoured cable
- Model
- BDM Ex-B
- Body Material
- Nickel-Plated Brass / Stainless Steel
- Seal Material
- NBR, PTFE, or Silicone
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP68
- Operating Temperature
- -40°C to +100°C
- Applicable Cable
- Non-Armoured Cables
Key features
- Unarmoured cable entryThe Ex-B construction clamps an unarmoured cable at the enclosure entry.
- Seal-material optionsNBR, PTFE and silicone options address different sealing-material requirements.
- Metal body optionsNickel-plated brass and stainless-steel bodies are available.
Ex-V Single-Seal Armoured Cable Gland
23 / Brass cable entry
Ex-V Single-Seal Armoured Cable Gland
An Ex-V single-seal metal gland with armour clamping for steel-wire and braided armoured cable constructions.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- An armoured-cable installation calls for the Ex-V single-seal arrangement.
Key specifications
- Product Type
- Single-seal armoured cable gland
- Model
- Ex-V
- Body Material
- Brass or stainless steel
- Seal Material
- Silicone or NBR
Product specifications
Construction and details

Assembly arrangement and dimensions
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Model specification tablesFurther specifications
- Applicable Cable
- Steel Wire Armour (SWA), Braided Armour, Jacketed Armour
Key features
- Single-seal constructionEx-V combines a single sealing arrangement with armour retention.
- Body and seal optionsThe range includes brass or stainless-steel bodies with silicone or NBR sealing options.
Ex-VI Clamping Gland for Unarmoured Cable
24 / Brass cable entry
Ex-VI Clamping Gland for Unarmoured Cable
An Ex-VI metal clamping gland for unarmoured cable, with NBR or silicone sealing parts.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- An unarmoured cable needs an Ex-VI clamping gland at a threaded equipment entry.
Key specifications
- Product Type
- Clamping gland for unarmoured cable
- Model
- Ex-VI
- Body Material
- Nickel-plated brass, SS304 stainless steel, or SS316 stainless steel
- Seal Material
- NBR or Silicone
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · H · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
- Applicable Cable
- Non-Armoured Cables
Key features
- Cable-clamping constructionEx-VI retains the unarmoured cable within the metal body.
- Two seal optionsThe sealing arrangement uses NBR or silicone, depending on the configuration.
- Entry threadsMetric, NPT and G versions are included in this construction.
Ex-VIG Clamping Gland for Unarmoured Cable
25 / Brass cable entry
Ex-VIG Clamping Gland for Unarmoured Cable
An Ex-VIG clamping gland for unarmoured cable, offered in nickel-plated brass and stainless-steel body configurations.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- A clamping gland with a nickel-plated brass or stainless steel body.
Key specifications
- Product Type
- Clamping gland for unarmoured cable
- Model
- BDM-VIG / Ex-VIG
- Body Material
- Nickel-Plated Brass / Stainless Steel (304, 316)
- Seal Material
- NBR or Silicone
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · H · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
- Applicable Cable
- Non-Armoured Cables
Key features
- Ex-VIG model identityBDM-VIG and Ex-VIG identify this unarmoured-cable clamping construction.
- Body-material choicesThe range includes nickel-plated brass, 304 stainless steel and 316 stainless steel.
- Elastomer seal choicesNBR and silicone sealing options are available.
Ex-VIIIG Single-Seal Armoured Cable Gland
26 / Brass cable entry
Ex-VIIIG Single-Seal Armoured Cable Gland
An Ex-VIIIG gland combining single sealing and armour clamping for wire-, braid- or tape-armoured cable.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- An armoured cable requires the Ex-VIIIG single-seal construction.
Key specifications
- Product Type
- Single-seal armoured cable gland
- Model
- Ex-VIIIG / BDM-VIIIG
- Body Material
- Nickel-Plated Brass / Stainless Steel (304, 316)
- Seal Material
- Silicone Rubber
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
- Applicable Cable
- Steel Wire, Braided, and Steel Tape Armoured Cables
Key features
- Single sealing with armour clampingThe Ex-VIIIG form combines one sealing arrangement with mechanical armour retention.
- Silicone sealsThe sealing components use silicone rubber.
- Metal body choicesNickel-plated brass and 304 or 316 stainless-steel versions are available.
Ex-VIIG Double-Seal Armoured Cable Gland
27 / Brass cable entry
Ex-VIIG Double-Seal Armoured Cable Gland
An Ex-VIIG metal cable gland with double sealing and an armour-clamping system.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- An armoured cable entry requires the Ex-VIIG double-seal arrangement.
Key specifications
- Product Type
- Double-seal armoured cable gland
- Model
- Ex-VIIG / BDM-VIIG
- Body Material
- Nickel-Plated Brass / Stainless Steel (304, 316)
- Seal Material
- Silicone Rubber
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
- Applicable Cable
- Steel Wire, Braided, and Steel Tape Armoured Cables
Key features
- Double-seal arrangementTwo sealing stages accompany the armour-clamping system.
- Silicone sealing partsThe gland uses silicone seals.
- Brass and stainless optionsThe range includes nickel-plated brass and 304 or 316 stainless-steel bodies.
Ex-BG Clamping Gland for Unarmoured Cable
28 / Brass cable entry
Ex-BG Clamping Gland for Unarmoured Cable
An Ex-BG metal clamping gland for unarmoured cable, with NBR, PTFE or silicone sealing options and Metric, NPT or G entries.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- An unarmoured cable entry needs NBR, PTFE or silicone seal options with a Metric, NPT or G connection.
Key specifications
- Product Type
- Clamping gland for unarmoured cable
- Model
- BDM-BG / Ex-BG
- Body Material
- Nickel-Plated Brass / Stainless Steel
- Seal Material
- NBR, PTFE, or Silicone
Product specifications
Construction and details

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL
Model specification tables
Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.
Further specifications
- Ingress Protection
- IP66
- Operating Temperature
- -40°C to +100°C
- Applicable Cable
- Non-Armoured Cables
Key features
- Unarmoured-cable clampEx-BG retains the cable without an armour-clamping assembly.
- Three seal-material optionsNBR, PTFE and silicone are available as configuration options.
- Three entry-thread systemsMetric, NPT and G versions serve different equipment entries.
BDM-BDT / Ex-BDT Threaded Stopping Plug
29 / Brass cable entry
BDM-BDT / Ex-BDT Threaded Stopping Plug
A BDM-BDT / Ex-BDT metal stopping plug for closing an unused threaded enclosure opening.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- A threaded enclosure entry is unused and needs a solid closure.
Key specifications
- Product Type
- Threaded stopping plug / blanking plug
- Model
- BDM-BDT / Ex-BDT
- Body Material
- Nickel-Plated Brass / Stainless Steel (304, 316)
- Seal Material
- NBR, PTFE or silicone
Product specifications
Construction and details

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: H · GL · AG
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
Key features
- Solid threaded closureThe plug closes an opening without passing a cable through it.
- Metal body optionsNickel-plated brass and 304 or 316 stainless-steel versions are available.
BGJ-A Female-to-Female Pipe Coupler
30 / Brass cable entry
BGJ-A Female-to-Female Pipe Coupler
A BGJ-A metal pipe coupler with female threads at both ends for joining threaded connections.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- Two male-threaded connections need a female-to-female coupler.
Key specifications
- Product Type
- Female-to-female pipe coupler / reducer
- Model
- BGJ-A
- Body Material
- Nickel-Plated Brass / Stainless Steel
- Thread 1 (Female)
- G (BSP) (Standard); M, NPT (Custom)
Product specifications
Construction and details

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: L
Model specification tablesFurther specifications
- Thread 2 (Female)
- G (BSP) (Standard); M, NPT (Custom)
- Ingress Protection
- IP65
Key features
- Two female-thread endsThe coupler joins male-threaded mating components.
- Straight or reducing formsBGJ-A includes straight and reducing connection forms.
- Metal body optionsNickel-plated brass and stainless-steel versions are available.
BGJ-B Thread Adapter — Reducer and Enlarger
31 / Brass cable entry
BGJ-B Thread Adapter — Reducer and Enlarger
A BGJ-B metal thread adapter for changing the connection size at a threaded entry.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- The equipment entry and adjoining connection need different thread sizes.
Key specifications
- Product type
- Thread adapter — reducer or enlarger
- Body material
- Nickel-plated brass or stainless steel
- Model series
- BGJ-B
Product specifications
Construction and details

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: L · GL
Model specification tablesKey features
- Reducer or enlarger functionThe adapter changes the threaded connection size.
- Metric, NPT and G seriesThe BGJ-B model tables cover Metric, NPT and G dimensional series.
- Metal constructionBrass and stainless-steel body options are available.
BGJ-C Male-to-Male Reducing Nipple
32 / Brass cable entry
BGJ-C Male-to-Male Reducing Nipple
A BGJ-C reducing nipple with male threads at both ends for joining female-threaded connections.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- Two female-threaded components need a male-to-male connecting nipple.
Key specifications
- Connection
- Male-to-male threaded connection
- Body material
- Nickel-plated brass or stainless steel
- Model series
- BGJ-C
Product specifications
Construction and details

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: L · GL
Model specification tablesKey features
- Male threads at both endsThe nipple screws into two female-threaded mating connections.
- Compact reducing connectionThe reducing form joins connections of different sizes.
- Metric, NPT and G seriesThe dimensional range includes Metric, NPT and G model series.
BGJ-D Male-to-Female Reducing Bushing
33 / Brass cable entry
BGJ-D Male-to-Female Reducing Bushing
A BGJ-D reducing bushing with a larger male thread around a smaller female-threaded opening.
Product reference
- Construction
- Explosion-Protected Brass Glands
- Application
- A larger female-threaded entry needs to accept a smaller male-threaded component.
Key specifications
- Connection
- Larger male thread to smaller female thread
- Body material
- Nickel-plated brass or stainless steel
- Model series
- BGJ-D
- Ingress protection
- IP65
Product specifications
Construction and details

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: L
Model specification tablesKey features
- Male-to-female reductionThe outside male thread fits the larger opening; the inside female thread receives the smaller component.
- Metric, NPT and G formsThe range includes reductions within Metric, NPT and G thread systems.
Nickel-Plated Brass Waterproof Breathable Cable Gland
34 / Brass cable entry
Nickel-Plated Brass Waterproof Breathable Cable Gland
Seal and retain a cable while allowing the enclosure to breathe through a separate vent.
Product reference
- Construction
- Breathable Brass Cable Glands
- Application
- Cable entry with nickel-plated brass body and enclosure ventilation.
Key specifications
- Product Type
- Brass breathable cable gland
- Body material
- Nickel-plated brass
- Protection rating
- IP68
- Entry threads
- M10×1.5 to M25×1.5
Product specifications
Construction and details

Product views and dimensions
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL · H
Model specification tablesFurther specifications
- Cable diameter
- 3–16 mm, depending on size
- Clamping insert
- Nylon PA
- Seal material
- NBR or EPDM
- Operating temperature
- −40°C to +100°C; short term to +120°C
Key features
- Cable sealing and ventingThe cable seal and breathing path serve separate functions.
- Metric size optionsChoose the thread and cable sealing range together.
Model specification tables
Model sizes
Brass Cable Gland — Metric, PG, G and NPT
Brass cable entry
Brass Cable Gland — Metric, PG, G and NPT
Model specificationsMetric thread
| Model | Thread AG | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| M6-NP | M6×1 | 3.5-1 | 6 | 6-6.2 | 5 | 11 | 8 |
| M8-NP | M8×1 | 5.5-2 | 8 | 8-8.2 | 5 | 16 | 12 |
| M10-NP | M10×1 | 3-6.5 | 10.0 | 10-10.2 | 6.5 | 17 | 14 |
| M12-NP | M12×1.5 | 3-6.5 | 12.0 | 12-12.2 | 6.5 | 17 | 14 |
| M14-NP | M14×1.5 | 4-8 | 14.0 | 14-14.2 | 8 | 18 | 17 |
| M16-NP | M16×1.5 | 4-8 | 16.0 | 16-16.2 | 8 | 19 | 18 |
| M18-NP | M18×1.5 | 5-10 | 18.0 | 18-18.2 | 8 | 20 | 20 |
| M20-NP | M20×1.5 | 6-12 | 20.0 | 20-20.2 | 8 | 21 | 22 |
| M22-NP | M22×1.5 | 10-14 | 22.0 | 22-22.2 | 8 | 22 | 24 |
| M24-NP | M24×1.5 | 10-14 | 24.0 | 24-24.2 | 9 | 22 | 24/27 |
| M25A-NP | M25×1.5 | 10-14 | 25.0 | 25-25.2 | 9 | 22 | 24/27 |
| M25B-NP | M25×1.5 | 16-8 | 25 | 25-25.2 | 9 | 27 | 27 |
| M25C-NP | M25×1.5 | 13-18 | 25.0 | 25-25.2 | 9 | 27 | 30/27 |
| M27A-NP | M27×1.5 | 13-18 | 27.0 | 27-27.2 | 9 | 27 | 30 |
| M27B-NP | M27×2 | 18-13 | 27 | 27-27.2 | 9 | 27 | 30 |
| M28A-NP | M28×1.5 | 13-18 | 28.0 | 28-28.2 | 9 | 27 | 30 |
| M28B-NP | M28×2 | 18-13 | 28 | 28-28.2 | 9 | 27 | 30 |
| M30A-NP | M30×1.5 | 13-18 | 30.0 | 30-30.2 | 9 | 27 | 30/32 |
| M30B-NP | M30×2 | 18-13 | 30 | 30-30.2 | 9 | 29 | 30/32 |
| M32A-NP | M32×1.5 | 15-22 | 32.0 | 32-32.2 | 10 | 29 | 35 |
| M32B-NP | M32×1.5 | 20-16 | 32 | 32-32.2 | 10 | 29 | 35 |
| M32B-NP | M32×1.5 | 20-16 | 32 | 32-32.2 | 10 | 29 | 35 |
| M32C-NP | M32×2 | 22-15 | 32 | 32-32.2 | 10 | 29 | 35 |
| M33A-NP | M33×1.5 | 15-22 | 33.0 | 33-33.2 | 10 | 29 | 35/36 |
| M33B-NP | M33×2 | 22-15 | 33 | 33-33.2 | 10 | 29 | 35 |
| M36A-NP | M36×1.5 | 18-25 | 36.0 | 36-36.2 | 10 | 31 | 40 |
| M36B-NP | M36×2 | 25-18 | 36 | 36-36.2 | 10 | 31 | 40 |
| M37A-NP | M37×1.5 | 18-25 | 37.0 | 37-37.2 | 10 | 31 | 40 |
| M37B-NP | M37×2 | 25-18 | 37 | 37-37.2 | 10 | 31 | 40 |
| M40A-NP | M40×1.5 | 18-25 | 40.0 | 40-40.2 | 11 | 31 | 40/45 |
| M40B-NP | M40×2 | 25-18 | 40 | 40-40.2 | 11 | 31 | 40/45 |
| M40C-NP | M40×1.5 | 22-30 | 40.0 | 40-40.2 | 11 | 35 | 45 |
| M40D-NP | M40×2 | 30-22 | 40 | 40-40.2 | 11 | 35 | 45 |
| M42A-NP | M42×1.5 | 22-30 | 42.0 | 42-42.2 | 11 | 35 | 45 |
| M42B-NP | M42×2 | 30-22 | 42 | 42-42.2 | 11 | 35 | 45 |
| M47A-NP | M47×1.5 | 25-33 | 47.0 | 47-47.2 | 11 | 37 | 50 |
| M47B-NP | M47×2 | 33-25 | 47 | 47-47.2 | 11 | 37 | 50 |
| M48A-NP | M48×1.5 | 25-33 | 48.0 | 48-48.2 | 11 | 37 | 50/52 |
| M48B-NP | M48×2 | 33-25 | 48 | 48-48.2 | 11 | 37 | 50/52 |
| M50A-NP | M50×1.5 | 32-38 | 50.0 | 50-50.2 | 13 | 37 | 57/55 |
| M50B-NP | M50×2 | 38-32 | 50 | 50-50.2 | 12 | 37 | 57/55 |
| M54A-NP | M54×1.5 | 32-38 | 54.0 | 54-54.2 | 13 | 37 | 57 |
| M54B-NP | M54×2 | 38-32 | 54 | 54-54.2 | 12 | 38 | 57 |
| M56A-NP | M56×1.5 | 38-32 | 56 | 56-56.2 | 12 | 38 | 57/59 |
| M56B-NP | M56×2 | 38-32 | 56 | 56-56.2 | 12 | 38 | 57/59 |
| M60A-NP | M60×1.5 | 37-44 | 60.0 | 60-60.2 | 14 | 38 | 64 |
| M60B-NP | M60×2 | 44-37 | 60 | 60-60.2 | 13 | 38 | 64 |
| M63A-NP | M63×1.5 | 37-44 | 63.0 | 63-63.2 | 14 | 38 | 64/68 |
| M63B-NP | M63×2 | 44-37 | 63 | 63-63.2 | 13 | 38 | 64/68 |
| M64A-NP | M64×1.5 | 44-37 | 64 | 64-64.2 | 13 | 38 | 64/68 |
| M64B-NP | M64×2 | 37-44 | 64.0 | 64-64.2 | 14 | 38 | 64/68 |
| M72-NP | M72×2 | 42-52 | 72.0 | 72-72.2 | 16 | 44 | 78 |
| M75-NP | M75×2 | 55-45 | 75 | 75-75.2 | 15 | 42 | 78 |
| M80-NP | M80×2 | 62-50 | 80 | 80-80.2 | 18 | 46 | 86/88 |
| M88-NP | M88×2 | 70-60 | 88 | 88-88.2 | 18 | 46 | 98 |
| M100-NP | M100×2 | 80-70 | 100 | 100-100.2 | 20 | 50 | 110 |
| M110-NP | M110×2 | 90-80 | 110 | 110-110.2 | 20 | 57 | 120 |
| M120-NP | M120×2 | 102-90 | 120 | 120-120.2 | 20 | 57 | 135 |
| M125-NP | M125×2 | 108-98 | 125 | 125-125.2 | 24 | 65 | 135 |
| M150-NP | M150×2 | 125-110 | 150 | 150-150.5 | 25 | 70 | 160 |
Model specificationsPG thread
| Model | Thread AG | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| PG7-NP | PG7 | 3-6.5 | 12.5 | 12.5-12.7 | 6.5 | 17 | 14/15 |
| PG9-NP | PG9 | 4-8 | 15.2 | 15.2-15.4 | 8 | 19 | 17/18 |
| PG11-NP | PG11 | 5-10 | 18.6 | 18.6-18.8 | 8 | 21 | 20/21 |
| PG13.5-NP | PG13.5 | 6-12 | 20.4 | 20.4-20.6 | 8 | 22 | 22/23 |
| PG16-NP | PG16 | 10-14 | 22.5 | 22.5-22.7 | 8 | 23 | 24/25 |
| PG19A-NP | PG19 | 10-14 | 25.0 | 25-25.2 | 9 | 25 | 24/27 |
| PG19B-NP | PG19 | 16-8 | 25 | 25-25.2 | 9 | 25 | 27 |
| PG21A-NP | PG21 | 13-18 | 28.3 | 28.3-28.5 | 9 | 27 | 30 |
| PG21B-NP | PG21 | 16-9 | 28.3 | 28.3-28.5 | 9 | 27 | 30/32 |
| PG25-NP | PG25 | 15-22 | 32.0 | 32-32.2 | 10 | 29 | 35 |
| PG29-NP | PG29 | 18-25 | 37.0 | 37-37.2 | 10 | 31 | 40 |
| PG36-NP | PG36 | 25-33 | 47.0 | 47-47.2 | 11 | 37 | 50 |
| PG42-NP | PG42 | 32-38 | 54.0 | 54-54.2 | 13 | 37 | 57 |
| PG48-NP | PG48 | 37-44 | 59.3 | 59.3-59.5 | 14 | 38 | 64 |
| PG63-NP | PG63 | 52-42 | 72 | 72-72.2 | 15 | 42 | 78 |
Model specificationsG/NPT threads
| Model | Thread AG | Cable diameter range (mm) | Thread outside diameter (mm) | Number of teeth per inch | Thread length GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| G1/4-NP | G1/4 | 3-6.5 | 13.1 | 19 | 6.5 | 13.5 | 14/15 |
| G3/8-NP | G3/8 | 4-8 | 16.6 | 19 | 8 | 17 | 18/19 |
| G1/2-NP | G1/2 | 6-12 | 20.9 | 14 | 8 | 22 | 22/23 |
| G3/4-NP | G3/4 | 13-18 | 26.4 | 14 | 9 | 25 | 30 |
| G1-NP | G1 | 18-25 | 33.2 | 11 | 10 | 29 | 40 |
| G1-1/4-NP | G1-1/4 | 25-33 | 41.9 | 11 | 11 | 35 | 50 |
| G1-1/2-NP | G1-1/2 | 32-38 | 47.8 | 11 | 12 | 37 | 57/55 |
| G2-NP | G2 | 37-44 | 59.6 | 11 | 14 | 38 | 64 |
| G2-1/2-NP | G2-1/2 | 42-52 | 75.1 | 11 | 16 | 42 | 78/80 |
| G3-NP | G3 | 65-70 | 87.8 | 11 | 18 | 45 | 94 |
| NPT1/4-NP | NPT1/4 | 3-6.5 | 13.6 | 18 | 6.5 | 13.5 | 14/15 |
| NPT3/8-NP | NPT3/8 | 4-8 | 17.0 | 18 | 8 | 17 | 18/19 |
| NPT1/2-NP | NPT1/2 | 6-12 | 21.2 | 14 | 8 | 22 | 22 |
| NPT3/4-NP | NPT3/4 | 13-18 | 26.5 | 14 | 9 | 25 | 30 |
| NPT1-NP | NPT1 | 18-25 | 33.2 | 11.5 | 10 | 29 | 40 |
| NPT1-1/4-NP | NPT1-1/4 | 25-33 | 41.9 | 11.5 | 11 | 35 | 50 |
| NPT1-1/2-NP | NPT1-1/2 | 32-38 | 48.0 | 11.5 | 12 | 37 | 57 |
| NPT2-NP | NPT2 | 37-44 | 60.0 | 11.5 | 14 | 38 | 64 |
| NPT2-1/2-NP | NPT2-1/2 | 42-52 | 72.6 | 8 | 16 | 42 | 78 |
| NPT3-NP | NPT3 | 70-65 | 88.6 | 8 | 15 | 45 | 98 |
Model specificationsLarger cable diameter
| Model | Thread AG | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| M12-NP | M12×1.5 | 4-8 | 12.0 | 12-12.2 | 8 | 18 | 17/14 |
| M14-NP | M14×1.5 | 5-10 | 14.0 | 14-14.2 | 8 | 19 | 20/17 |
| M16-NP | M16×1.5 | 5-10 | 16.0 | 16-16.2 | 8 | 19 | 20/18 |
| M20-NP | M20×1.5 | 10-14 | 20.0 | 20-20.2 | 8 | 22 | 24/22 |
| M20-NP | M20×1.5 | 16-9 | 20 | 20-20.2 | 9 | 27 | 27 |
| M25-NP | M25×1.5 | 15-22 | 25.0 | 25-25.2 | 9 | 29 | 35/27 |
| M32-NP | M32×1.5 | 18-25 | 32.0 | 32-32.2 | 10 | 31 | 40/35 |
| M40-NP | M40×1.5 | 25-33 | 40.0 | 40-40.2 | 11 | 37 | 50/45 |
| M50-NP | M50×1.5 | 37-44 | 50.0 | 50-50.2 | 13 | 38 | 64/55 |
| M63-NP | M63×1.5 | 42-52 | 63.0 | 63-63.2 | 14 | 44 | 78/68 |
| M72-NP | M72×1.5 | 62-50 | 72 | 72-72.2 | 15 | 45 | 86/78 |
| M80-NP | M80×1.5 | 70-60 | 80 | 80-80.2 | 18 | 46 | 98/86 |
| M88-NP | M88×1.5 | 80-70 | 88 | 88-88.2 | 18 | 46 | 110/98 |
90-Degree Brass Fitting for Flexible Conduit
Brass cable entry
90-Degree Brass Fitting for Flexible Conduit
Model specifications90-Degree Brass Fitting for Flexible Conduit — thread and cable dimensions
| Model | Cable range | Thread outside diameter (mm) | Thread length (mm) | Total length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M12-6.5-9D | 3-6.5 | 12 | 9 | 45 | 20/21 |
| M16-6.5-9D | 3-6.5 | 16 | 9 | 45 | 20/21 |
| M16-8-9D | 4-8 | 16 | 9 | 45 | 20/21 |
| M16-10-9D | 5-10 | 16 | 10 | 57 | 20/25 |
| M18-10-9D | 5-10 | 18 | 10 | 57 | 20/25 |
| M20-10-9D | 5-10 | 20 | 10 | 57 | 20/25 |
| M20-12-9D | 6-12 | 20 | 10 | 57 | 24/25 |
| M20-14-9D | 10-14 | 20 | 15 | 58 | 24/30 |
| M22-14-9D | 10-14 | 22 | 15 | 58 | 24/30 |
| M24-12-9D | 6-12 | 24 | 15 | 58 | 24/30 |
| M24-14-9D | 10-14 | 24 | 15 | 58 | 24/30 |
| M25-14-9D | 10-14 | 25 | 15 | 58 | 24/30 |
| M25-16-9D | 10-16 | 25 | 15 | 75 | 28/34 |
| M25-18-9D | 13-18 | 25 | 15 | 75 | 30/34 |
| M27-16-9D | 10-16 | 27 | 15 | 75 | 28/34 |
| M27-18-9D | 13-18 | 27 | 15 | 75 | 30/34 |
| M30-16-9D | 10-16 | 30 | 15 | 75 | 28/34 |
| M30-18-9D | 13-18 | 30 | 15 | 75 | 30/34 |
| M32-18-9D | 13-18 | 32 | 15 | 75 | 30/34 |
| M32-22-9D | 15-22 | 32 | 15 | 75 | 30/34 |
| M32-25-9D | 18-25 | 32 | 15 | 90 | 40/43 |
| M33-25-9D | 18-25 | 33 | 15 | 90 | 40/43 |
| M36-22-9D | 15-22 | 36 | 15 | 90 | 36/43 |
| M36-25-9D | 18-25 | 36 | 15 | 90 | 40/43 |
| M40-25-9D | 18-25 | 40 | 15 | 90 | 40/43 |
| M40-30-9D | 22-30 | 40 | 15 | 105 | 50/55 |
| M40-32-9D | 22-32 | 40 | 15 | 115 | 50/55 |
| M42-9D | 22-32 | 42 | 15 | 115 | 50/55 |
| M48-9D | 22-32 | 48 | 15 | 115 | 50/55 |
| M50-9D | 30-38 | 50 | 15 | 115 | 55/60 |
| M56-9D | 30-38 | 56 | 15 | 115 | 55/60 |
| M60-9D | 37-44 | 60 | 18 | 125 | 65/70 |
| M63-9D | 37-44 | 63 | 18 | 125 | 75/75 |
| M64-9D | 37-44 | 64 | 18 | 125 | 65/70 |
Extended-Thread Metal Cable Gland for Thick Panels
Brass cable entry
Extended-Thread Metal Cable Gland for Thick Panels
Model specificationsExtended-Thread Metal Cable Gland for Thick Panels — thread and cable dimensions
| Model | Thread AG | Cable diameter range (mm) | Thread outside diameter (mm) | Thread length GL (mm) | Spanner size (mm) | Length H (mm) |
|---|---|---|---|---|---|---|
| M8L | M8*1.0 | 2-5 | 8 | 8 | 12 | — |
| M10L | M10*1.0 | 3-6.5 | 10 | 10 | 14 | — |
| M12L | M12×1.5 | 3-6.5 | 12 | 10 | 14 | 17 |
| M14L | M14*1.5 | 4-8 | 14 | 12 | 17 | — |
| M16L | M16×1.5 | 4-8 | 16 | 12 | 18 | 19 |
| M18L | M18×1.5 | 5-10 | 18 | 12 | 20 | 21 |
| M20L | M20×1.5 | 6-12 | 20 | 12 | 22 | 22 |
| M22L | M22×1.5 | 10-14 | 22 | 12 | 24 | 23 |
| M24L | M24*1.5 | 10-14 | 24 | 12 | 24/27 | — |
| M25-14L | M25×1.5 | 10-14 | 25 | 12 | 24/27 | 25 |
| M25-18L | M25×1.5 | 13-18 | 25 | 12 | 30/27 | 27 |
| M27L | M27*1.5 | 13-18 | 27 | 12 | 30 | — |
| M28L | M28*1.5 | 13-18 | 28 | 12 | 30 | — |
| M30L | M30*1.5 | 13-18 | 30 | 14 | 30/32 | — |
| M32L | M32×1.5 | 15-22 | 32 | 15 | 35 | 29 |
| M33L | M33*1.5 | 15-22 | 33 | 14 | 35 | — |
| M36L | M36*1.5 | 18-25 | 36 | 14 | 40 | — |
| M37L | M37*1.5 | 18-25 | 37 | 14 | 40 | — |
| M40-25L | M40×1.5 | 18-25 | 40 | 15 | 40/45 | 31 |
| M40-30L | M40×1.5 | 22-30 | 40 | 15 | 45 | 35 |
| M42L | M42*1.5 | 22-30 | 42 | 15 | 45 | — |
| M47L | M47*1.5 | 25-33 | 47 | 15 | 50 | — |
| M48L | M48*1.5 | 25-33 | 48 | 15 | 50/52 | — |
| M50L | M50×1.5 | 32-38 | 50 | 15 | 57/55 | 37 |
| M54L | M54*1.5 | 32-38 | 54 | 15 | 57 | — |
| M60L | M60*1.5 | 37-44 | 60 | 16 | 64 | — |
| M63L | M63×1.5 | 37-44 | 63 | 18 | 64/68 | 38 |
| M64L | M64*2.0 | 37-44 | 64 | 16 | 64/68 | — |
| M72L | M72*2.0 | 42-52 | 72 | 18 | 78 | — |
| M75L | M75*2.0 | 42-52 | 75 | 18 | 78/80 | — |
| M80L | M80*2.0 | 50-62 | 80 | 20 | 86/88 | — |
| M88L | M88*2.0 | 60-70 | 88 | 20 | 98 | — |
| M100L | M100*2.0 | 70-80 | 100 | 22 | 110 | — |
Brass Cable Gland with Silicone Seals
Brass cable entry
Brass Cable Gland with Silicone Seals
Model specificationsBrass Cable Gland with Silicone Seals — thread and cable dimensions
| Model | Thread AG | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Joint length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| M8-SI | M8X1 | 5.5-2 | 8 | 8-8.2 | 5 | 16 | 12 |
| M12A-SI | M12X1 | 6.5-3 | 12 | 12-12.2 | 7 | 19 | 14 |
| M12B-SI | M 12X1.25 | 8-3 | 12 | 12-12.2 | 7 | 16 | 16 |
| M12C-SI | M12X1.5 | 8-3 | 12 | 12-12.2 | 7 | 16 | 16 |
| M14-SI | M 14X1.5 | 8-3 | 14 | 14-14.2 | 7 | 16 | 16 |
| M16-SI | M16X1.5 | 9-4 | 16 | 16-16.2 | 8 | 20 | 20/18 |
| M18-SI | M18X1.5 | 5-10 | 18.0 | 18-18.2 | 8 | 20 | 20 |
| M20-SI | M20X1.5 | 8-12 | 20.0 | 20-20.2 | 8 | 21 | 22 |
| M25-SI | M25X1.5 | 18-15 | 25 | 25-25.2 | 9 | 23 | 30 |
| M32-SI | M32X1.5 | 22-18 | 32 | 32-32.2 | 10 | 26 | 35 |
| M40-SI | M40X1.5 | 30-25 | 40 | 40-40.2 | 11 | 30 | 45 |
| M50-SI | M50X1.5 | 38-35 | 50 | 50-50.2 | 12 | 32 | 55 |
| M63-SI | M63X1.5 | 44-38 | 63 | 63-63.2 | 13 | 35 | 68 |
Multi-Hole Brass Cable Gland for 2–8 Cables
Brass cable entry
Multi-Hole Brass Cable Gland for 2–8 Cables
Model specificationsMulti-Hole Brass Cable Gland for 2–8 Cables — thread and cable dimensions
| Model | Thread | F | M2 | M3 | M4 | M5 | M6 | M7 | M8 |
|---|---|---|---|---|---|---|---|---|---|
| M12/* | M12×1.5 | / | 3-1.2 | 3-1.2 | 2.3-1 | / | / | / | / |
| M16/* | M16×1.5 | / | 4-1.6 | 4-1.6 | 2.3-1 | 2.5-1.0 | 2.0-1.0 | / | / |
| M18/* | M18×1.5 | 6×10 | 3.5-2 | 3.5-2 | 3-1.2 | 2.6-1.5 | 2.2-1 | / | / |
| M20/* | M20×1.5 | 5×11.5 | 5.3-1.5 | 5.3-1.5 | 4.2-1.7 | 3-1.2 | 3-1.2 | 3-1.2 | 3-1.2 |
| M22/* | M22×1.5 | 6×14 | 6-2.5 | 6-2.5 | 4.5-2 | / | / | / | / |
| M25/* | M25×1.5 | 6×14 | 8.7-4 | 8.7-4 | 5-2 | 3.5-1.5 | 3.5-1.5 | 3.5-1.5 | 3.5-1.5 |
| M27/* | M27×1.5 | 7×18 | 8.7-4.5 | 8.7-4.5 | 7-3.5 | 3.5-1.5 | 3.5-1.5 | 3.5-1.5 | 3.5-1.5 |
| M32/* | M32×1.5 | 8×22 | 10-5 | 10-5 | 9-4.5 | 8.0-4.0 | 7-3.5 | 6-3 | / |
| PG7/* | PG7 | / | 3-1.2 | 3-1.2 | 2.3-1 | / | / | / | / |
| PG9/* | PG9 | / | 4-1.6 | 4-1.6 | 2.3-1 | 2.5-1.0 | 2-1 | / | / |
| PG11/* | PG11 | 6×10 | 3.5-2 | 3.5-2 | 3-1.2 | 2.6-1.5 | 2.2-1 | / | / |
| PG13.5/* | PG13.5 | 5×11.5 | 5.3-1.5 | 5.3-1.5 | 4.2-1.7 | 4.2-1.7 | / | / | / |
| PG16/* | PG16 | 6×14 | 6-2.5 | 6-2.5 | 4.5-2 | / | / | / | / |
| PG21/* | PG21 | 7×18 | 8.7-4.5 | 8.7-4.5 | 7-3.5 | 3.5-1.5 | 3.5-1.5 | 3.5-1.5 | / |
| PG29/* | pG29 | 8×22 | 10-5 | 10-5 | 9-4.5 | 8.0-4.0 | 7-3.5 | 6-3 | / |
| G1/2/* | G1/2 | 5×11.5 | 5.3-1.5 | 5.3-1.5 | 4.2-1.7 | 3-1.2 | 3-1.2 | 3-1.2 | 3-1.2 |
| G3/4/* | G3/4 | 7×18 | 7×18 | 8.7-4.5 | 5-2 | 3.5-1.5 | 3.5-1.5 | 3.5-1.5 | 3.5-1.5 |
| G1/* | G1 | 8×22 | 8×22 | 10-5 | 10-5 | 8.0-4.0 | 7-3.5 | 6-3 | / |
Brass Cable Gland with Flexible Bend Guard
Brass cable entry
Brass Cable Gland with Flexible Bend Guard
Model specificationsMetric thread
| Model | Cable diameter range (mm) | Thread length (mm) | Body Height mm | Spanner size (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) |
|---|---|---|---|---|---|---|
| M12-FL | 3-6.5 | 6.5 | 52 | 14 | 12 | 12-12.3 |
| M16-FL | 4-8 | 8 | 65 | 18 | 16 | 16-16.3 |
| M20-FL | 6-12 | 8 | 88 | 22 | 20 | 20-20.3 |
| M22-FL | 10-14 | 8 | 96 | 24 | 22 | 22-22.3 |
| M25A-FL | 13-18 | 9 | 110 | 30/27 | 25 | 25-25.3 |
| M25B-FL | 9-16 | 10 | 111 | 30 | 25 | 25-25.3 |
| M32-FL | 15-22 | 11 | 120 | 35 | 32 | 32-32.5 |
Model specificationsPG thread
| Model | Cable diameter range (mm) | Thread length (mm) | Body Height mm | Spanner size (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) |
|---|---|---|---|---|---|---|
| PG7-FL | 3-6.5 | 6.5 | 52 | 14/15 | 12.5 | 12.5-12.8 |
| PG9-FL | 4-8 | 8 | 65 | 17/18 | 15.2 | 15.2-15.5 |
| PG11-FL | 5-10 | 8 | 75 | 20/21 | 18.6 | 18.6-18.9 |
| PG13.5-FL | 6-12 | 8 | 88 | 22/23 | 20.4 | 20.4-20.7 |
| PG16A-FL | 10-14 | 8 | 96 | 24/25 | 22.5 | 22.5-22.8 |
| PG16B-FL | 6-12 | 10 | 98 | 24 | 22.5 | 22.5-22.8 |
| PG21A-FL | 13-18 | 9 | 110 | 30 | 28.3 | 28.3-28.6 |
| PG21B-FL | 9-16 | 10 | 111 | 30 | 28.3 | 28.3-28.6 |
Double-Locked Brass Cable Gland
Brass cable entry
Double-Locked Brass Cable Gland
Model specificationsPG thread
| Model | Cable diameter range (mm) | Thread length (mm) | Body Height mm | Spanner size (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) |
|---|---|---|---|---|---|---|
| PG7-DL | 3-6.5 | 5 | 25 | 14 | 12.5 | 12.5-12.8 |
| PG9-DL | 4-8 | 6 | 27 | 17 | 15.2 | 15.2-15.5 |
| PG11-DL | 5-10 | 6 | 29 | 20 | 18.6 | 18.6-18.9 |
| PG13.5-DL | 6-12 | 6.5 | 31 | 22 | 20.4 | 20.4-20.7 |
| PG16-DL | 10-14 | 6.5 | 31 | 24 | 22.5 | 22.5-22.8 |
| PG21-DL | 13-18 | 7 | 37 | 30 | 28.3 | 28.3-28.6 |
| PG29-DL | 18-25 | 8 | 42 | 40 | 37 | 37-37.3 |
| PG36-DL | 22-32 | 8 | 48 | 50 | 47 | 47-47.3 |
| PG42-DL | 32-38 | 9 | 50 | 57 | 54 | 54-54.3 |
| PG48-DL | 37-44 | 10 | 51 | 64 | 59.3 | 59.3-59.6 |
Model specificationsMetric thread
| Model | Cable diameter range (mm) | Thread length (mm) | Body Height mm | Spanner size (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) |
|---|---|---|---|---|---|---|
| M12A-DL | 3-6.5 | 6.5 | 25 | 14 | 12.0 | 12-12.3 |
| M12B-DL | 4-8 | 8 | 27 | 17/14 | 12.0 | 12-12.3 |
| M14-DL | 4-8 | 6 | 27 | 17 | 14 | 14-14.3 |
| M16A-DL | 4-8 | 8 | 27 | 18 | 16.0 | 16-16.3 |
| M16B-DL | 5-10 | 8 | 29 | 20/18 | 16.0 | 16-16.3 |
| M18-DL | 5-10 | 8 | 29 | 20 | 18.0 | 18-18.3 |
| M20A-DL | 6-12 | 8 | 31 | 22 | 20.0 | 20-20.3 |
| M20B-DL | 10-14 | 8 | 31 | 24/22 | 20.0 | 20-20.3 |
| M22-DL | 10-14 | 6.5 | 31 | 24 | 22 | 22-22.3 |
| M24-DL | 10-14 | 6.5 | 31 | 24/27 | 24 | 24-24.3 |
| M25-DL | 13-18 | 9 | 37 | 30/27 | 25.0 | 25-25.3 |
| M27-DL | 13-18 | 7 | 37 | 30 | 27 | 27-27.3 |
| M28-DL | 13-18 | 7 | 37 | 30 | 28 | 28-28.3 |
| M30-DL | 13-18 | 8 | 37 | 30/32 | 30 | 30-30.3 |
| M32-DL | 18-25 | 10 | 42 | 40/35 | 32.0 | 32-32.3 |
| M33-DL | 18-25 | 8 | 42 | 40 | 33 | 33-33.3 |
| M36-DL | 18-25 | 8 | 42 | 40 | 36 | 36-36.3 |
| M37-DL | 18-25 | 8 | 42 | 40 | 37 | 37-37.3 |
| M40-DL | 22-32 | 8 | 48 | 50 | 40 | 40-40.3 |
| M42-DL | 22-32 | 8 | 48 | 50 | 42 | 42-42.3 |
| M47-DL | 22-32 | 8 | 48 | 50 | 47 | 47-47.3 |
| M48-DL | 22-32 | 8 | 48 | 50/52 | 48 | 48-48.3 |
| M50-DL | 32-38 | 13 | 50 | 57/55 | 50.0 | 50-50.3 |
| M54-DL | 32-38 | 9 | 50 | 57 | 54 | 54-54.3 |
| M56-DL | 32-38 | 9 | 50 | 57/59 | 56 | 56-56.3 |
| M60-DL | 37-44 | 10 | 51 | 64 | 60 | 60-60.3 |
| M63-DL | 37-44 | 14 | 51 | 64/68 | 63.0 | 63-63.3 |
| M64-DL | 37-44 | 10 | 51 | 64 | 64 | 64-64.3 |
BR-Series Breathable Brass Cable Gland
Brass cable entry
BR-Series Breathable Brass Cable Gland
Model specificationsBR-Series Breathable Brass Cable Gland — thread and cable dimensions
| Model | Cable diameter range (mm) | Thread length GL (mm) | Thread outside diameter (mm) | Spanner size (mm) | Nominal thread diameter AG (mm) |
|---|---|---|---|---|---|
| M12-BR | 3-6.5 | 7 | 11.9 | 17 | 12 |
| M14-BR | 4-8 | 7 | 13.9 | 19 | 14 |
| M16-BR | 4-8 | 7 | 15.9 | 21 | 16 |
| M18-BR | 5-10 | 8 | 17.9 | 22 | 18 |
| M20-BR | 6-12 | 8 | 19.9 | 24 | 20 |
| M22-BR | 10-14 | 8 | 21.9 | 27 | 22 |
| M25-BR | 10-16 | 9 | 24.9 | 27 | 25 |
| M27-BR | 13-18 | 9 | 26.9 | 30 | 27 |
| M28-BR | 13-18 | 9 | 27.9 | 30 | 28 |
| M30-BR | 13-18 | 10 | 29.9 | 36 | 30 |
| M32-BR | 15-22 | 10 | 31.9 | 38 | 32 |
| M37-BR | 18-25 | 12 | 36.9 | 42 | 37 |
| M40-BR | 22-30 | 12 | 39.9 | 46 | 40 |
MG-Series Brass Cable Gland
Brass cable entry
MG-Series Brass Cable Gland
Model specificationsMetric thread
| Entry thread | Model | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Spanner size (mm) | Joint length H (mm) |
|---|---|---|---|---|---|---|---|
| M12X1.5 | M12A-MG | 3-5.3 | 12 | 12-12.3 | 8 | 17/17 | — |
| M12X1.5 | M12B-MG | 4.5-7.8 | 12 | 12-12.3 | 8 | 17/17 | — |
| M16X1.5 | M16A-MG | 4-7 | 16 | 16-16.3 | 9 | 22/22 | — |
| M16X1.5 | M16B-MG | 6-10 | 16 | 16-16.3 | 9 | 22/22 | — |
| M20X1.5 | M20A-MG | 5-8.8 | 20 | 20-20.3 | 9.5 | 24/24 | — |
| M20X1.5 | M20B-MG | 7-12 | 20 | 20-20.3 | 9.5 | 24/24 | — |
| M20X1.5 | M20C-MG | 9-14 | 20 | 20-20.3 | 9.5 | 26/26 | — |
| M25X1.5 | M25-MG | 12-16 | 25 | 25-25.4 | 12 | 32/32 | — |
| M32X1.5 | M32A-MG | 16-22 | 32 | 32-32.4 | 12.5 | 41/41 | — |
| M32X1.5 | M32B-MG | 18-25 | 32 | 32-32.4 | 12.5 | 40 | 33 |
| M40 x 1.5 | M40A-MG | 21-25 | 40 | 40-40.4 | 15 | 50/50 | — |
| M40 x 1.5 | M40B-MG | 24-30 | 40 | 40-40.4 | 15 | 50/50 | — |
| M50 X 1.5 | M50A-MG | 26-32 | 50 | 50-50.4 | 15 | 60/60 | — |
| M50 X 1.5 | M50B-MG | 31-41 | 50 | 50-50.4 | 15 | 60/60 | — |
| M63X1.5 | M63A-MG | 40-46 | 63 | 63-63.4 | 15 | 73/73 | — |
| M63X1.5 | M63B-MG | 44-51 | 63 | 63-63.4 | 15 | 73/73 | — |
| M75X1.5 | M75A-MG | 50-56 | 75 | 75-75.6 | 15 | 85/88 | — |
| M75X1.5 | M75B-MG | 56-66 | 75 | 75-75.6 | 15 | 85/88 | — |
| M90X1.5 | M90A-MG | 58-68 | 90 | 90-91 | 20 | 102/106 | — |
| M90X1.5 | M90B-MG | 66-77 | 90 | 90-91 | 20 | 102/106 | — |
| M 100X1.5 | M100A-MG | 58-68 | 100 | 100-101 | 25 | 116/120 | — |
| M 100X1.5 | M100B-MG | 66-77 | 100 | 100-101 | 25 | 116/120 | — |
Model specificationsPG thread
| Entry thread | Model | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Spanner size (mm) | Joint length H (mm) |
|---|---|---|---|---|---|---|---|
| PG7 | PG7A-MG | 3-5.3 | 12.5 | 12.5-12.8 | 8 | 17/17 | — |
| PG7 | PG7B-MG | 4.5・7.8 | 12.5 | 12.5-12.8 | 8 | 17/17 | — |
| PG9 | PG9A-MG | 3-5.8 | 15.2 | 15.2-15.5 | 8 | 18/18 | — |
| PG9 | PG9B-MG | 4.5-7.8 | 15.2 | 15.2-15.5 | 8 | 18/18 | — |
| PG11 | PG11A-MG | 4-7 | 18.6 | 18.6-18.9 | 9 | 22/22 | — |
| PG11 | PG11B-MG | 6-10 | 18.6 | 18.6-18.9 | 9 | 22/22 | — |
| PG13.5 | PG13.5A-MG | 5-8.8 | 20.4 | 20.4-20.7 | 9.5 | 24/24 | — |
| PG13.5 | PG13.5B-MG | 7-12 | 20.4 | 20.4-20.7 | 9.5 | 24/24 | — |
| PG16 | PG16A-MG | 7-11 | 22.5 | 22.5-22.8 | 9.5 | 26/26 | — |
| PG16 | PG16B-MG | 9-14 | 22.5 | 22.5-22.8 | 9.5 | 26/26 | — |
| PG21 | PG21A-MG | 12-16 | 28.3 | 28.3-28.7 | 12 | 32/32 | — |
| PG21 | PG21B-MG | 14-18 | 28.3 | 28.3-28.7 | 12 | 32/32 | — |
| PG29 | PG29A-MG | 16-22 | 37 | 37-37.4 | 12.5 | 41/41 | — |
| PG29 | PG29B-MG | 18-25 | 37.0 | 37-37.4 | 12.5 | 40 | 33.0 |
| PG36 | PG36A-MG | 21-25 | 47 | 47-47.4 | 15 | 50/50 | — |
| PG36 | PG36B-MG | 24-30 | 47 | 47-47.4 | 15 | 50/50 | — |
Model specificationsG/NPT threads
| Entry thread | Model | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| G3/8 “ | G3/8A-MG | 4-7 | 16.662 | 16.7-16.9 | 9 | 22/22 |
| G3/8 “ | G3/8B-MG | 6-10 | 16.662 | 16.7-16.9 | 9 | 22/22 |
| G1/2 “ | G1/2A-MG | 7-11 | 20.955 | 21-21.2 | 9.5 | 26/26 |
| G1/2 “ | G1/2B-MG | 9-14 | 20.955 | 21-21.2 | 9.5 | 26/26 |
| G3/4 “ | G3/4A-MG | 12-16 | 26.441 | 26.5-26.8 | 12 | 32/32 |
| G3/4 “ | G3/4B-MG | 14-18 | 26.441 | 26.5-26.8 | 12 | 32/32 |
| G1″ | G1A-MG | 16-22 | 33.249 | 33.3-33.6 | 12.5 | 41/41 |
| G1″ | G1-MG | 18-25 | 33.249 | 33.3-33.6 | 12.5 | 41/41 |
| G11/4 “ | G11/4A-MG | 21-25 | 41.91 | 42-42.3 | 15 | 50/50 |
| G11/4 “ | G11/4B-MG | 24-30 | 41.91 | 42-42.3 | 15 | 50/50 |
| G11/2 “ | G11/2A-MG | 26-32 | 47.803 | 48-48.4 | 15 | 60/60 |
| G11/2 “ | G11/2B-MG | 31-41 | 47.803 | 48-48.4 | 15 | 60/60 |
| G2 “ | G2A-MG | 40-46 | 59.614 | 60-60.4 | 15 | 73/73 |
| G2 “ | G2B-MG | 44-51 | 59.614 | 60-60.4 | 15 | 73/73 |
| G21/2 “ | G2 1/2A-MG | 50-56 | 75.184 | 75.2-75.6 | 18 | 85/88 |
| G21/2 “ | G2 1/2B-MG | 66-56 | 75.184 | 75.2-75.6 | 18 | 85/88 |
| NPT3/8 “ | NPT3/8A-MG | 4-7 | 17.055 | 13 | 22 | |
| NPT3/8 “ | NPT3/8B-MG | 6-10 | 17.055 | 13 | 22 | |
| NPT1/2″ | NPT1/2A-MG | 7-11 | 21.223 | 13 | 26 | |
| NPT1/2″ | NPT1/2B-MG | 9-14 | 21.223 | 13 | 26 | |
| NPT3/4 “ | NPT3/4A-MG | 12-16 | 26.568 | 14 | 32 | |
| NPT3/4 “ | NPT3/4B-MG | 14-18 | 26.568 | 14 | 32 | |
| NPT1 “ | NPT1A-MG | 16-22 | 33.227 | 15 | 41 | |
| NPT1 “ | NPT1B-MG | 18-25 | 33.227 | 15 | 41 | |
| NPT1 1/4 “ | NPT11/4A-MG | 21-25 | 41.984 | 15 | 50 | |
| NPT1 1/4 “ | NPT11/4B-MG | 240-30 | 41.984 | 15 | 50 |
Straight-Through Brass Cable Gland — Standard and Long Thread
Brass cable entry
Straight-Through Brass Cable Gland — Standard and Long Thread
Model specificationsMetric thread
| Model | Thread AG | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Joint length H(mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| M12-TR | M 12X1.5 | 3-6.5 | 12 | 12-12.2 | 6.5 | 17 | 14 |
| M14-TR | MMX 1.5 | 8-4 | 14 | 14-14.2 | 7 | 19 | 17 |
| M16-TR | M16X1.5 | 4-8 | 16 | 16-16.2 | 8 | 19 | 18 |
| M18-TR | M18X1.5 | 5-10 | 18 | 18-18.2 | 8 | 21 | 20 |
| M20-TR | M20X1.5 | 6-12 | 20 | 20-20.2 | 8 | 22 | 22 |
| M22-TR | M22X1.5 | 10-14 | 22 | 22-22.2 | 8 | 23 | 24 |
| M24-TR | M24X1.5 | 14-10 | 24 | 24-24.2 | 9 | 25 | 24/27 |
| M25A-TR | M25X1.5 | 10-14 | 25 | 25-25.2 | 9 | 25 | 24/27 |
| M25B-TR | M25X1.5 | 16-8 | 25 | 25-25.2 | 9 | 27 | 27 |
| M25C-TR | M25X1.5 | 13-18 | 25 | 25-25.2 | 9 | 27 | 30/27 |
| M27A-TR | M27X1.5 | 13-18 | 27 | 27-27.2 | 9 | 27 | 30 |
| M27B-TR | M27X2 | 18-13 | 27 | 27-27.2 | 9 | 27 | 30 |
| M28A-TR | M28X1.5 | 18-13 | 28 | 28-28.2 | 9 | 27 | 30 |
| M28B-TR | M28X2 | 18-13 | 28 | 28-28.2 | 9 | 27 | 30 |
| M30A-TR | M30X1.5 | 18-13 | 30 | 30-30.2 | 9 | 29 | 30/32 |
| M30B-TR | M30X2 | 18-13 | 30 | 30-30.2 | 9 | 29 | 30/32 |
| M32A-TR | M32X1.5 | 15-22 | 32 | 32-32.2 | 10 | 29 | 35 |
| M32B-TR | M32X1.5 | 20-16 | 32 | 32-32.2 | 10 | 29 | 35 |
| M32C-TR | M32X2 | 22-15 | 32 | 32-32.2 | 10 | 29 | 35 |
| M36A-TR | M36X1.5 | 18-25 | 36 | 36-36.2 | 10 | 31 | 40 |
| M36B-TR | M36X2 | 25-18 | 36 | 36-36.2 | 10 | 31 | 40 |
| M37A-TR | M37X1.5 | 25-18 | 37 | 37-37.2 | 10 | 31 | 40 |
| M37B-TR | M37X2 | 25-18 | 37 | 37-37.2 | 10 | 31 | 40 |
| M40A-TR | M40X1.5 | 18-25 | 40 | 40-40.2 | 10 | 31 | 40/45 |
| M40B-TR | M40X2 | 25-18 | 40 | 40-40.2 | 11 | 31 | 40/45 |
| M40C-TR | M40X1.5 | 22-30 | 40 | 40-40.2 | 10 | 35 | 45 |
| M40D-TR | M40X2 | 30-22 | 40 | 40-40.2 | 11 | 35 | 45 |
| M42A-TR | M42X1.5 | 30-22 | 42 | 42-42.2 | 11 | 35 | 45 |
| M42B-TR | M42X2 | 30-22 | 42 | 42-42.2 | 11 | 35 | 45 |
| M60A-TR | M60X1.5 | 44-37 | 60 | 60-60.2 | 13 | 38 | 64 |
| M60B-TR | M60X2 | 44-37 | 60 | 60-60.2 | 13 | 38 | 64 |
| M63A-TR | M63X1.5 | 44-37 | 63 | 63-63.2 | 13 | 38 | 64/68 |
| M63B-TR | M63X2 | 44-37 | 63 | 63-63.2 | 13 | 38 | 64/68 |
| M64A-TR | M64X1.5 | 44-37 | 64 | 64-64.2 | 13 | 38 | 64/68 |
| M64B-TR | M64X2 | 44-37 | 64 | 64-64.2 | 13 | 38 | 64/68 |
| M72-TR | M72X2 | 52-42 | 72 | 72-72.2 | 15 | 42 | 78 |
| M75-TR | M75X2 | 52-42 | 75 | 75-75.2 | 15 | 42 | 78 |
| M80-TR | M80X2 | 62-50 | 80 | 80-80.2 | 15 | 45 | 86/88 |
| M88-TR | M88X2 | 70-60 | 88 | 88-88.2 | 15 | 45 | 98 |
| M100-TR | M100X2 | 80-70 | 100 | 100-100.2 | 15 | 45 | 110 |
Model specificationsPG thread
| Model | Thread AG | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Spanner size (mm) | Joint length H (mm) |
|---|---|---|---|---|---|---|---|
| PG7-TR | PG7 | 3-6.5 | 12.5 | 12.5-12.7 | 6.5 | 14/15 | 17 |
| PG9-TR | PG9 | 4-8 | 15.2 | 15.2-15.4 | 8 | 17/18 | 19 |
| PG11-TR | PG11 | 5-10 | 18.6 | 18.6-18.8 | 8 | 20/21 | 21 |
| PG13.5-TR | PG13.5 | 6-12 | 20.4 | 20.4-20.6 | 8 | 22/23 | 22 |
| PG16-TR | PG16 | 10-14 | 22.5 | 22.5-22.7 | 8 | 24/25 | 23 |
| PG21-TR | PG21 | 13-18 | 28.3 | 28.3-28.5 | 9 | 30 | 27 |
| PG25-TR | PG25 | 22-15 | 32 | 32-32.2 | 10 | 35 | — |
| PG29-TR | PG29 | 18-25 | 37.0 | 37-37.2 | 10 | 40 | 31 |
| PG36-TR | PG36 | 25-33 | 47.0 | 47-47.2 | 10 | 50 | 37 |
| PG42-TR | PG42 | 32-38 | 54.0 | 54-54.2 | 10 | 57 | 37 |
| PG48-TR | PG48 | 44-37 | 59.3 | 59.3-59.5 | 14 | 64 | — |
| PG63-TR | PG63 | 52-42 | 72 | 72-72.2 | 15 | 78 | — |
90-Degree Brass Conduit Fitting
Brass cable entry
90-Degree Brass Conduit Fitting
Model specifications90-Degree Brass Conduit Fitting — thread and cable dimensions
| Model | Thread outside diameter | Cable diameter range (mm) | Length (mm) | Thread length GL (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M12-9D | 12 | 3-6.5 | 45 | 9 | 20/21 |
| M16-6.5-9D | 16 | 3-6.5 | 45 | 9 | 20/21 |
| M16-8-9D | 16 | 4-8 | 45 | 9 | 20/21 |
| M16-10-9D | 16 | 5-10 | 57 | 10 | 20/25 |
| M18-9D | 18 | 5-10 | 57 | 10 | 20/25 |
| M20-10-9D | 20 | 5-10 | 57 | 10 | 24/25 |
| M20-12-9D | 20 | 6-12 | 57 | 10 | 24/30 |
| M20-14-9D | 20 | 8-14 | 58 | 15 | 24/30 |
| M22-9D | 22 | 8-14 | 58 | 15 | 24/30 |
| M24-12-9D | 24 | 6-12 | 58 | 15 | 24/30 |
| M24-14-9D | 24 | 8-14 | 58 | 15 | 24/30 |
| M25-14-9D | 25 | 8-14 | 58 | 15 | 28/34 |
| M25-16-9D | 25 | 10-16 | 75 | 15 | 30/34 |
| M25-18-9D | 25 | 13-18 | 75 | 15 | 28/34 |
| M27-16-9D | 27 | 10-16 | 75 | 15 | 30/34 |
| M27-18-9D | 27 | 13-18 | 75 | 15 | 28/34 |
| M30-16-9D | 30 | 10-16 | 75 | 15 | 30/34 |
| M30-18-9D | 30 | 13-18 | 75 | 15 | 30/34 |
| M32-18-9D | 32 | 13-18 | 75 | 15 | 30/34 |
| M32-22-9D | 32 | 15-22 | 75 | 15 | 30/43 |
| M32-25-9D | 32 | 18-25 | 90 | 15 | 40/43 |
| M33-9D | 33 | 18-25 | 90 | 15 | 40/43 |
| M36-22-9D | 36 | 15-22 | 90 | 15 | 36/43 |
| M36-25-9D | 36 | 18-25 | 90 | 15 | 40/43 |
| M40-25-9D | 40 | 18-25 | 90 | 15 | 40/43 |
| M40-30-9D | 40 | 22-30 | 105 | 15 | 50/55 |
| M40-32-9D | 40 | 22-32 | 115 | 15 | 50/55 |
| M42-9D | 42 | 22-32 | 115 | 15 | 50/55 |
| M48-9D | 48 | 22-32 | 115 | 15 | 50/55 |
| M50-9D | 50 | 30-38 | 115 | 15 | 55/60 |
| M56-9D | 56 | 30-38 | 115 | 15 | 55/60 |
| M60-9D | 60 | 37-44 | 125 | 18 | 65/70 |
| M63-9D | 63 | 37-44 | 125 | 18 | 75/75 |
| M64-9D | 64 | 37-44 | 125 | 18 | 65/70 |
M-NW Female-Thread Cable Gland for Threaded Conduit
Brass cable entry
M-NW Female-Thread Cable Gland for Threaded Conduit
Model specificationsM-NW Female-Thread Cable Gland for Threaded Conduit — thread and cable dimensions
| Model | Entry thread | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread Length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M12-NW | M12×1.5 | 6.5-3 | 12 | 12-12.2 | 7 | 14 |
| M14-NW | M14×1.5 | 8-4 | 14 | 14-14.2 | 7 | 17 |
| M16-NW | M16×1.5 | 8-4 | 16 | 16-16.2 | 8 | 18 |
| M18-NW | M18×1.5 | 10-5 | 18 | 18-18.2 | 8 | 20 |
| M20-NW | M20×1.5 | 12-6 | 20 | 20-20.2 | 8 | 22 |
| M22-NW | M22×1.5 | 14-10 | 22 | 22-22.2 | 8 | 24 |
| M24-NW | M24×1.5 | 14-10 | 24 | 24-24.2 | 9 | 24/27 |
| M25A-NW | M25×1.5 | 14-10 | 25 | 25-25.2 | 9 | 24/27 |
| M25B-NW | M25×1.5 | 16-8 | 25 | 25-25.2 | 9 | 27 |
| M25C-NW | M25×1.5 | 18-13 | 25 | 25-25.2 | 9 | 30/27 |
| M27A-NW | M27×1.5 | 18-13 | 27 | 27-27.2 | 9 | 30 |
| M27B-NW | M27×2 | 18-13 | 27 | 27-27.2 | 9 | 30 |
| M28A-NW | M28×1.5 | 18-13 | 28 | 28-28.2 | 9 | 30 |
| M28B-NW | M28×2 | 18-13 | 28 | 28-28.2 | 9 | 30 |
| M30A-NW | M30×1.5 | 18-13 | 30 | 30-30.2 | 9 | 30/32 |
| M30B-NW | M30×2 | 18-13 | 30 | 30-30.2 | 9 | 30/32 |
| M32A-NW | M32×1.5 | 22-15 | 32 | 32-32.2 | 10 | 35 |
| M32B-NW | M32×1.5 | 20-16 | 32 | 32-32.2 | 10 | 35 |
| M32C-NW | M32×2 | 22-15 | 32 | 32-32.2 | 10 | 35 |
| M36A-NW | M36×1.5 | 25-18 | 36 | 36-36.2 | 10 | 40 |
| M36B-NW | M36×2 | 25-18 | 36 | 36-36.2 | 10 | 40 |
| M37A-NW | M37×1.5 | 25-18 | 37 | 37-37.2 | 10 | 40 |
| M37B-NW | M37×2 | 25-18 | 37 | 37-37.2 | 10 | 40 |
| M40A-NW | M40×1.5 | 25-18 | 40 | 40-40.2 | 11 | 40/45 |
| M40B-NW | M40×2 | 25-18 | 40 | 40-40.2 | 11 | 40/45 |
| M40C-NW | M40×1.5 | 30-22 | 40 | 40-40.2 | 11 | 45 |
| M40D-NW | M40×2 | 30-22 | 40 | 40-40.2 | 11 | 45 |
| M42A-NW | M42×1.5 | 30-22 | 42 | 42-42.2 | 11 | 45 |
| M42B-NW | M42×2 | 30-22 | 42 | 42-42.2 | 11 | 45 |
| M50A-NW | M50×1.5 | 38-32 | 50 | 50-50.2 | 12 | 57/55 |
| M50B-NW | M50×2 | 38-32 | 50 | 50-50.2 | 12 | 57/55 |
| M60A-NW | M60×1.5 | 44-37 | 60 | 60-60.2 | 13 | 64 |
| M60B-NW | M60×2 | 44-37 | 60 | 60-60.2 | 13 | 64 |
| M63A-NW | M63×1.5 | 44-37 | 63 | 63-63.2 | 13 | 64/68 |
| M63B-NW | M63×2 | 44-37 | 63 | 63-63.2 | 13 | 64/68 |
| M72-NW | M72×2 | 52-42 | 72 | 72-72.2 | 15 | 78 |
| M75-NW | M75×2 | 52-42 | 75 | 75-75.2 | 15 | 78 |
| M80-NW | M80×2 | 62-50 | 80 | 80-80.2 | 18 | 86/88 |
| M88-NW | M88×2 | 70-60 | 88 | 88-88.2 | 18 | 98 |
| M100-NW | M100×2 | 80-70 | 100 | 100-100.2 | 20 | 110 |
M-NLW Internal-Thread Cable Gland
Brass cable entry
M-NLW Internal-Thread Cable Gland
Model specificationsM-NLW Internal-Thread Cable Gland — thread and cable dimensions
| Model | Entry thread | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread Length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M12-NLW | M12×1.5 | 6.5-3 | 12 | 12-12.2 | 7 | 14 |
| M14-NLW | M14×1.5 | 8-4 | 14 | 14-14.2 | 7 | 17 |
| M16-NLW | M16×1.5 | 8-4 | 16 | 16-16.2 | 8 | 18 |
| M18-NLW | M18×1.5 | 10-5 | 18 | 18-18.2 | 8 | 20 |
| M20-NLW | M20×1.5 | 12-6 | 20 | 20-20.2 | 8 | 22 |
| M22-NLW | M22×1.5 | 14-10 | 22 | 22-22.2 | 8 | 24 |
| M24-NLW | M24×1.5 | 14-10 | 24 | 24-24.2 | 9 | 24/27 |
| M25A-NLW | M25×1.5 | 14-10 | 25 | 25-25.2 | 9 | 24/27 |
| M25B-NLW | M25×1.5 | 16-8 | 25 | 25-25.2 | 9 | 27 |
| M25C-NLW | M25×1.5 | 18-13 | 25 | 25-25.2 | 9 | 30/27 |
| M27A-NLW | M27×1.5 | 18-13 | 27 | 27-27.2 | 9 | 30 |
| M27B-NLW | M27×2 | 18-13 | 27 | 27-27.2 | 9 | 30 |
| M28A-NLW | M28×1.5 | 18-13 | 28 | 28-28.2 | 9 | 30 |
| M28B-NLW | M28×2 | 18-13 | 28 | 28-28.2 | 9 | 30 |
| M30A-NLW | M30×1.5 | 18-13 | 30 | 30-30.2 | 9 | 30/32 |
| M30B-NLW | M30×2 | 18-13 | 30 | 30-30.2 | 9 | 30/32 |
| M32A-NLW | M32×1.5 | 22-15 | 32 | 32-32.2 | 10 | 35 |
| M32B-NLW | M32×1.5 | 20-16 | 32 | 32-32.2 | 10 | 35 |
| M32C-NLW | M32×2 | 22-15 | 32 | 32-32.2 | 10 | 35 |
| M36A-NLW | M36×1.5 | 25-18 | 36 | 36-36.2 | 10 | 40 |
| M36B-NLW | M36×2 | 25-18 | 36 | 36-36.2 | 10 | 40 |
| M37A-NLW | M37×1.5 | 25-18 | 37 | 37-37.2 | 10 | 40 |
| M37B-NLW | M37×2 | 25-18 | 37 | 37-37.2 | 10 | 40 |
| M40A-NLW | M40×1.5 | 25-18 | 40 | 40-40.2 | 11 | 40/45 |
| M40B-NLW | M40×2 | 25-18 | 40 | 40-40.2 | 11 | 40/45 |
| M40C-NLW | M40×1.5 | 30-22 | 40 | 40-40.2 | 11 | 45 |
| M40D-NLW | M40×2 | 30-22 | 40 | 40-40.2 | 11 | 45 |
| M42A-NLW | M42×1.5 | 30-22 | 42 | 42-42.2 | 11 | 45 |
| M42B-NLW | M42×2 | 30-22 | 42 | 42-42.2 | 11 | 45 |
| M50A-NLW | M50×1.5 | 38-32 | 50 | 50-50.2 | 12 | 57/55 |
| M50B-NLW | M50×2 | 38-32 | 50 | 50-50.2 | 12 | 57/55 |
| M60A-NLW | M60×1.5 | 44-37 | 60 | 60-60.2 | 13 | 64 |
| M60B-NLW | M60×2 | 44-37 | 60 | 60-60.2 | 13 | 64 |
| M63A-NLW | M63×1.5 | 44-37 | 63 | 63-63.2 | 13 | 64/68 |
| M63B-NLW | M63×2 | 44-37 | 63 | 63-63.2 | 13 | 64/68 |
| M72-NLW | M72×2 | 52-42 | 72 | 72-72.2 | 15 | 78 |
| M75-NLW | M75×2 | 52-42 | 75 | 75-75.2 | 15 | 78 |
| M80-NLW | M80×2 | 62-50 | 80 | 80-80.2 | 18 | 86/88 |
| M88-NLW | M88×2 | 70-60 | 88 | 88-88.2 | 18 | 98 |
| M100-NLW | M100×2 | 80-70 | 100 | 100-100.2 | 20 | 110 |
M-LBK Double-Flare Cable Gland
Brass cable entry
M-LBK Double-Flare Cable Gland
Model specificationsM-LBK Double-Flare Cable Gland — thread and cable dimensions
| Model | Entry thread | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread Length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M12-LBK | M12×1.5 | 6.5-3 | 12 | 12-12.2 | 7 | 14 |
| M14-LBK | M14×1.5 | 8-4 | 14 | 14-14.2 | 7 | 17 |
| M16-LBK | M16×1.5 | 8-4 | 16 | 16-16.2 | 8 | 18 |
| M18-LBK | M18×1.5 | 10-5 | 18 | 18-18.2 | 8 | 20 |
| M20-LBK | M20×1.5 | 12-6 | 20 | 20-20.2 | 8 | 22 |
| M22-LBK | M22×1.5 | 14-10 | 22 | 22-22.2 | 8 | 24 |
| M24-LBK | M24×1.5 | 14-10 | 24 | 24-24.2 | 9 | 24/27 |
| M25A-LBK | M25×1.5 | 14-10 | 25 | 25-25.2 | 9 | 24/27 |
| M25B-LBK | M25×1.5 | 16-8 | 25 | 25-25.2 | 9 | 27 |
| M25C-LBK | M25×1.5 | 18-13 | 25 | 25-25.2 | 9 | 30/27 |
| M27A-LBK | M27×1.5 | 18-13 | 27 | 27-27.2 | 9 | 30 |
| M27B-LBK | M27×2 | 18-13 | 27 | 27-27.2 | 9 | 30 |
| M28A-LBK | M28×1.5 | 18-13 | 28 | 28-28.2 | 9 | 30 |
| M28B-LBK | M28×2 | 18-13 | 28 | 28-28.2 | 9 | 30 |
| M30A-LBK | M30×1.5 | 18-13 | 30 | 30-30.2 | 9 | 30/32 |
| M30B-LBK | M30×2 | 18-13 | 30 | 30-30.2 | 9 | 30/32 |
| M32A-LBK | M32×1.5 | 22-15 | 32 | 32-32.2 | 10 | 35 |
| M32B-LBK | M32×1.5 | 20-16 | 32 | 32-32.2 | 10 | 35 |
| M32C-LBK | M32×2 | 22-15 | 32 | 32-32.2 | 10 | 35 |
| M36A-LBK | M36×1.5 | 25-18 | 36 | 36-36.2 | 10 | 40 |
| M36B-LBK | M36×2 | 25-18 | 36 | 36-36.2 | 10 | 40 |
| M37A-LBK | M37×1.5 | 25-18 | 37 | 37-37.2 | 10 | 40 |
| M37B-LBK | M37×2 | 25-18 | 37 | 37-37.2 | 10 | 40 |
| M40A-LBK | M40×1.5 | 25-18 | 40 | 40-40.2 | 11 | 40/45 |
| M40B-LBK | M40×2 | 25-18 | 40 | 40-40.2 | 11 | 40/45 |
| M40C-LBK | M40×1.5 | 30-22 | 40 | 40-40.2 | 11 | 45 |
| M40D-LBK | M40×2 | 30-22 | 40 | 40-40.2 | 11 | 45 |
| M42A-LBK | M42×1.5 | 30-22 | 42 | 42-42.2 | 11 | 45 |
| M42B-LBK | M42×2 | 30-22 | 42 | 42-42.2 | 11 | 45 |
| M50A-LBK | M50×1.5 | 38-32 | 50 | 50-50.2 | 12 | 57/55 |
| M50B-LBK | M50×2 | 38-32 | 50 | 50-50.2 | 12 | 57/55 |
| M60A-LBK | M60×1.5 | 44-37 | 60 | 60-60.2 | 13 | 64 |
| M60B-LBK | M60×2 | 44-37 | 60 | 60-60.2 | 13 | 64 |
| M63A-LBK | M63×1.5 | 44-37 | 63 | 63-63.2 | 13 | 64/68 |
| M63B-LBK | M63×2 | 44-37 | 63 | 63-63.2 | 13 | 64/68 |
| M72-LBK | M72×2 | 52-42 | 72 | 72-72.2 | 15 | 78 |
| M75-LBK | M75×2 | 52-42 | 75 | 75-75.2 | 15 | 78 |
| M80-LBK | M80×2 | 62-50 | 80 | 80-80.2 | 18 | 86/88 |
| M88-LBK | M88×2 | 70-60 | 88 | 88-88.2 | 18 | 98 |
| M100-LBK | M100×2 | 80-70 | 100 | 100-100.2 | 20 | 110 |
MG-Series EMC Cable Gland
Brass cable entry
MG-Series EMC Cable Gland
Model specificationsMetric thread
| Model | Entry thread | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Spanner size (mm) | Joint length H (mm) |
|---|---|---|---|---|---|---|---|
| E.M12A-EMC | M 12X1.5 | 3-5.3 | 12 | 12-12.3 | 8 | 17/17 | — |
| E.M12B-EMC | M 12X1.5 | 4.5-7.8 | 12 | 12-12.3 | 8 | 17/17 | — |
| E.M16A-EMC | M16X1.5 | 4-7 | 16 | 16-16.3 | 9 | 22/22 | — |
| E.M16B-EMC | M16X1.5 | 6-10 | 16 | 16-16.3 | 9 | 22/22 | — |
| E.M20A-EMC | M20X1.5 | 5-8.8 | 20 | 20-20.3 | 9.5 | 24/24 | — |
| E.M20B-EMC | M20X1.5 | 7-12 | 20 | 20-20.3 | 9.5 | 24/24 | — |
| E.M20C-EMC | M20X1.5 | 9-14 | 20 | 20-20.3 | 9.5 | 26/26 | — |
| E.M25A-EMC | M25X1.5 | 12-16 | 25 | 25-25.4 | 9 | 27 | 27 |
| E.M25B-EMC | M25X1.5 | 14-18 | 25 | 25-25.4 | 12 | 32/32 | — |
| E.M32A-EMC | M32X1.5 | 16-22 | 32 | 32-32.4 | 12.5 | 41/41 | — |
| E.M32B-EMC | M32X1.5 | 18-25 | 32 | 32-32.4 | 10 | 40/35 | 31 |
| E.M40A-EMC | M40X1.5 | 21-25 | 40 | 40-40.4 | 15 | 50/50 | — |
| E.M40B-EMC | M40X1.5 | 24-30 | 40 | 40-40.4 | 15 | 50/50 | — |
| E.M50A-EMC | M50X1.5 | 26-32 | 50 | 50-50.4 | 15 | 60/60 | — |
| E.M50B-EMC | M50X1.5 | 31-41 | 50 | 50-50.4 | 15 | 60/60 | — |
| E.M63A-EMC | M63X1.5 | 40-46 | 63 | 63-63.4 | 15 | 73/73 | — |
| E.M63B-EMC | M63X1.5 | 44-51 | 63 | 63-63.4 | 15 | 73/73 | — |
| E.M75A-EMC | M75X1.5 | 50-56 | 75 | 75-75.6 | 15 | 85/85 | — |
| E.M75B-EMC | M75X1.5 | 56-66 | 75 | 75-75.6 | 15 | 85/85 | — |
| E.M90A-EMC | M90X1.5 | 58-68 | 90 | 90-91 | 20 | 102/102 | — |
| E.M90B-EMC | M90X1.5 | 66-77 | 90 | 90-91 | 20 | 102/102 | — |
| E.M100A-EMC | M100X1.5 | 58-68 | 100 | 100-101 | 25 | 116/116 | — |
| E.M100B-EMC | M100X1.5 | 66-77 | 100 | 100-101 | 25 | 116/116 | — |
Model specificationsPG thread
| Model | Entry thread | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| E.PG7A-EMC | PG7-EMC | 3-5.3 | 12.5 | 12.5-12.8 | 8 | 17/17 |
| E.PG7B-EMC | PG7-EMC | 4.5-7.8 | 12.5 | 12.5-12.5 | 8 | 17/17 |
| E.PG9A-EMC | PG9-EMC | 3-5.8 | 15.2 | 15.2-15.5 | 8 | 18/18 |
| E.PG9B-EMC | PG9-EMC | 4.5-7.8 | 15.2 | 15.2-15.5 | 8 | 18/18 |
| E.PG11A-EMC | PG11-EMC | 4-7 | 18.6 | 18.6-18.9 | 9 | 22/22 |
| E.PG11B-EMC | PG11-EMC | 6-10 | 18.6 | 18.6-18.9 | 9 | 22/22 |
| E.PG13.5A-EMC | PG13.5-EMC | 5-8.8 | 20.4 | 20.4-20.7 | 9.5 | 24/24 |
| E.PG13.5B-EMC | PG13.5-EMC | 7-12 | 20.4 | 20.4-20.7 | 9.5 | 24/24 |
| E.PG16A-EMC | PG16-EMC | 7-11 | 22.5 | 22.5-22.8 | 9.5 | 26/26 |
| E.PG16B-EMC | PG16-EMC | 9-14 | 22.5 | 22.5-22.8 | 9.5 | 26/26 |
| E.PG21A-EMC | PG21-EMC | 12-16 | 28.3 | 28.3-28.7 | 12 | 32/32 |
| E.PG21B-EMC | PG21-EMC | 14-18 | 28.3 | 28.3-28.7 | 12 | 32/32 |
| E.PG29A-EMC | PG29-EMC | 16-22 | 37 | 37-37.4 | 12.5 | 41/41 |
| E.PG29B-EMC | PG29-EMC | 18-25 | 37 | 37-37.4 | 12.5 | 41/41 |
| E.PG36A-EMC | PG36-EMC | 21-25 | 47 | 47-47.4 | 15 | 50/50 |
| E.PG36B-EMC | PG36-EMC | 24-30 | 47 | 47-47.4 | 15 | 50/50 |
Model specificationsG/NPT threads
| Model | Entry thread | Cable diameter range (mm) | Thread outside diameter (mm) | Mounting hole diameter (mm) | Thread length GL (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| E.G3/8A-EMC | G(PF)3/8 “ | 4-7 | 16.662 | 16.7-16.9 | 9 | 22/22 |
| E.G3/8B-EMC | G(PF)3/8 “ | 6-10 | 16.662 | 16.7-16.9 | 9 | 22/22 |
| E.G3/4A-EMC | G(PF)3/4 “ | 12-16 | 26.441 | 26.5-26.8 | 12 | 32/32 |
| E.G3/4B-EMC | G(PF)3/4 “ | 14-18 | 26.441 | 26.5-26.8 | 12 | 32/32 |
| E.G1A-EMC | G(PF)1″ | 16-22 | 33.249 | 33.3-33.6 | 12.5 | 41/41 |
| E.G1B-EMC | G(PF)1″ | 18-25 | 33.249 | 33.3-33.6 | 12.5 | 41/41 |
| E.G11/4A-EMC | G(PF)1-1/4″ | 21-25 | 41.91 | 42-42.3 | 15 | 50/50 |
| E.G11/4B-EMC | G(PF)1-1/4″ | 24-30 | 41.91 | 42-42.3 | 15 | 50/50 |
| E.G11/2A-EMC | G(PF)1-1/2 “ | 26-32 | 47.803 | 48-48.4 | 15 | 60/60 |
| E.G11/2B-EMC | G(PF)1-1/2 “ | 31-41 | 47.803 | 48-48.4 | 15 | 60/60 |
| E.G2A-EMC | G(PF)2 “ | 40-46 | 59.614 | 60-60.4 | 15 | 73/73 |
| E.G2B-EMC | G(PF)2 “ | 44-51 | 59.614 | 60-60.4 | 15 | 73/73 |
| E.G21/2-EMC | G(PF)2-1/2 “ | 50-56 | 75.184 | 75.2-75.6 | 18 | 85/88 |
| E.G21/2-EMC | G(PF)2-1/2 “ | 66-56 | 75.184 | 75.2-75.6 | 18 | 85/88 |
| E.NPT3/8A-EMC | NPT3/8 “ | 4-7 | 17.055 | 13 | 22 | |
| E.NPT3/8B-EMC | NPT3/8 “ | 6-10 | 17.055 | 13 | 22 | |
| E.NPT1/2A-EMC | NPT1/2 “ | 7-11 | 21.223 | 13 | 26 | |
| E.NPT1/2B-EMC | NPT1/2 “ | 9-14 | 21.223 | 13 | 26 | |
| E.NPT3/4A-EMC | NPT3/4 “ | 12-16 | 26.568 | 14 | 32 | |
| E.NPT3/4B-EMC | NPT3/4 “ | 14-18 | 26.568 | 14 | 32 | |
| E.NPT1A-EMC | NPT1 “ | 16-22 | 33.227 | 15 | 41 | |
| E.NPT1B-EMC | NPT1 “ | 18-25 | 33.227 | 15 | 41 | |
| E.NPT11/4A-EMC | NPT 1-1/4 “ | 21-25 | 41.984 | 15 | 50 | |
| E.NPT11/4B-EMC | NPT 1-1/4 “ | 240-30 | 41.984 | 15 | 50 |
Spring-Contact EMC Cable Gland
Brass cable entry
Spring-Contact EMC Cable Gland
Model specificationsMetric thread
| Model | Height (mm) | Thread length (mm) | Cable diameter range (mm) | Spanner size (mm) |
|---|---|---|---|---|
| B.M12-EMC | 20 | 6 | 3-7 | 16 |
| B.M16-EMC | 24 | 7 | 4-10 | 20 |
| B.M20-EMC | 27 | 9 | 6-13 | 24 |
| B.M25-EMC | 29 | 8 | 9-17 | 30 |
| B.M32-EMC | 33 | 9 | 11-21 | 36 |
| B.M40-EMC | 41 | 9 | 19-28 | 45 |
| B.M5O-EMC | 45 | 9 | 26-35 | 55 |
| B.M63-EMC | 48 | 14 | 34-45 | 68 |
Model specificationsPG thread
| Model | Height (mm) | Thread length (mm) | Cable diameter range (mm) | Spanner size (mm) |
|---|---|---|---|---|
| B.PG7-EMC | 19 | 5 | 3-6.5 | 14 |
| B.PG9-EMC | 22 | 6 | 4-8 | 17 |
| B.PG11-EMC | 25 | 6 | 5-10 | 20 |
| B.PG13.5-EMC | 26 | 6.5 | 6-12 | 22 |
| B.PG16-EMC | 27 | 6.5 | 10-14 | 24 |
| B.PG21-EMC | 31 | 7 | 13-18 | 30 |
| B.PG29-EMC | 38 | 8 | 18-25 | 40 |
| B.PG36-EMC | 45 | 15 | 22-32 | 50 |
| B.PG42-EMC | 45 | 15 | 30-38 | 57 |
| B.PG48-EMC | 47 | 15 | 34-44 | 64 |
D-Series EMC Cable Gland
Brass cable entry
D-Series EMC Cable Gland
Model specificationsPG thread
| Model | Thread | Cable diameter range (mm) | Thread outside diameter (mm) | Plate diameter (mm) | Thread length GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| D.PG7-EMC | PG7 | 6.5-3 | 12.5 | 12.5-12.7 | 7 | 19 | 14 |
| D.PG9-EMC | PG9 | 8-4 | 15.2 | 15.2-15.4 | 8 | 20 | 17 |
| D.PG11-EMC | PG11 | 10-5 | 18.6 | 18.6-18.8 | 8 | 21 | 20/21 |
| D.PG13.5-EMC | PG13.5 | 12-6 | 20.4 | 20.4-20.6 | 8 | 22 | 22 |
| D.PG16-EMC | PG16 | 14-10 | 22.5 | 22.5-22.7 | 9 | 23 | 24 |
| D.PG19-EMC | PG19 | 14-10 | 25 | 25-25.2 | 9 | 25 | 24/27 |
| D.PG21-EMC | PG21 | 18-13 | 28.3 | 28.3-28.5 | 9 | 27 | 30 |
| D.PG25-EMC | PG25 | 22-15 | 32 | 32-32.2 | 10 | 29 | 35 |
| D.PG29-EMC | PG29 | 25-18 | 37 | 37-37.2 | 10 | 31 | 40 |
| D.PG36-EMC | PG36 | 33-25 | 47 | 47-47.2 | 11 | 37 | 50 |
| D.PG42-EMC | PG42 | 38-32 | 54 | 54-54.2 | 13 | 38 | 57 |
| D.PG48-EMC | PG48 | 44-37 | 59.3 | 59.3-59.5 | 14 | 38 | 64 |
| D.PG63-EMC | PG63 | 52-42 | 72 | 72-72.2 | 15 | 42 | 78 |
Model specificationsMetric thread
| Model | Thread | Cable diameter range (mm) | Thread outside diameter (mm) | Plate diameter (mm) | Thread length GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| D.M12-EMC | M12*1.5 | 6.5-3 | 12 | 12-12.2 | 7 | 19 | 14 |
| D.M14-EMC | M14*1.5 | 8-4 | 14 | 14-14.2 | 7 | 19 | 17 |
| D.M16-EMC | M16*1.5 | 8-4 | 16 | 16-16.2 | 8 | 20 | 18 |
| D.M18-EMC | M18*1.5 | 10-5 | 18 | 18-18.2 | 8 | 21 | 20 |
| D.M20-EMC | M20*1.5 | 12-6 | 20 | 20-20.2 | 8 | 22 | 22 |
| D.M22-EMC | M22*1.5 | 14-10 | 22 | 22-22.2 | 8 | 23 | 24 |
| D.M24-EMC | M24*1.5 | 14-10 | 24 | 24-24.2 | 9 | 25 | 24/27 |
| D.M25A-EMC | M25*1.5 | 14-10 | 25 | 25-25.2 | 9 | 25 | 24/27 |
| D.M25B-EMC | M25*1.5 | 18-13 | 25 | 25-25.2 | 9 | 27 | 30/27 |
| D.M27A-EMC | M27*1.5 | 18-13 | 27 | 27-27.2 | 9 | 27 | 30 |
| D.M27B-EMC | M27*2 | 18-13 | 27 | 27-27.2 | 9 | 27 | 30 |
| D.M28A-EMC | M28*1.5 | 18-13 | 28 | 28-28.2 | 9 | 27 | 30 |
| D.M28B-EMC | M28*2 | 18-13 | 28 | 28-28.2 | 9 | 27 | 30 |
| D.M30A-EMC | M30*1.5 | 18-13 | 30 | 30-30.2 | 9 | 29 | 30/32 |
| D.M30B-EMC | M30*2 | 18-13 | 30 | 30-30.2 | 9 | 29 | 30/32 |
| D.M32A-EMC | M32*1.5 | 22-15 | 32 | 32-32.2 | 10 | 29 | 35 |
| D.M32B-EMC | M32*2 | 22-15 | 32 | 32-32.2 | 10 | 29 | 35 |
| D.M33A-EMC | M33*1.5 | 22-15 | 33 | 33-33.2 | 10 | 29 | 35 |
| D.M33B-EMC | M33*2 | 22-15 | 33 | 33-33.2 | 10 | 29 | 35 |
| D.M36A-EMC | M36*1.5 | 25-18 | 36 | 36-36.2 | 10 | 31 | 40 |
| D.M36B-EMC | M36*2 | 25-18 | 36 | 36-36.2 | 10 | 31 | 40 |
| D.M37A-EMC | M37*1.5 | 25-18 | 37 | 37-37.2 | 10 | 31 | 40 |
| D.M37B-EMC | M37*2 | 25-18 | 37 | 37-37.2 | 10 | 31 | 40 |
| D.M40A-EMC | M40*1.5 | 25-18 | 40 | 40-40.2 | 11 | 31 | 40/45 |
| D.M40B-EMC | M40*2 | 25-18 | 40 | 40-40.2 | 11 | 31 | 40/45 |
| D.M40C-EMC | M40*1.5 | 30-22 | 40 | 40-40.2 | 11 | 35 | 45 |
| D.M40D-EMC | M40*2 | 30-22 | 40 | 40-40.2 | 11 | 35 | 45 |
| D.M42A-EMC | M42*1.5 | 30-22 | 42 | 42-42.2 | 11 | 35 | 45 |
| D.M42B-EMC | M42*2 | 30-22 | 42 | 42-42.2 | 11 | 35 | 45 |
| D.M47A-EMC | M47*1.5 | 33-25 | 47 | 47-47.2 | 11 | 37 | 50 |
| D.M47B-EMC | M47*2 | 33-25 | 47 | 47-47.2 | 11 | 37 | 50 |
| D.M48A-EMC | M48*1.5 | 33-25 | 48 | 48-48.2 | 11 | 37 | 50/52 |
| D.M48B-EMC | M48*2 | 33-25 | 48 | 48-48.2 | 11 | 37 | 50/52 |
| D.M50A-EMC | M50*1.5 | 38-32 | 50 | 50-50.2 | 12 | 37 | 50/55 |
| D.M50B-EMC | M50*2 | 38-32 | 50 | 50-50.2 | 12 | 37 | 50/55 |
| D.M54A-EMC | M54*1.5 | 38-32 | 54 | 54-54.2 | 12 | 38 | 57 |
| D.M54B-EMC | M54*2 | 38-32 | 54 | 54-54.2 | 12 | 38 | 57 |
| D.M56A-EMC | M56*1.5 | 38-32 | 56 | 56-56.2 | 12 | 38 | 57/59 |
| D.M56B-EMC | M56*2 | 38-32 | 56 | 56-56.2 | 12 | 38 | 57/59 |
| D.M60A-EMC | M60*1.5 | 44-37 | 60 | 60-60.2 | 13 | 38 | 64 |
| D.M60B-EMC | M60*2 | 44-37 | 60 | 60-60.2 | 13 | 38 | 64 |
| D.M63A-EMC | M63*1.5 | 44-37 | 63 | 63-63.2 | 13 | 38 | 64/68 |
| D.M63B-EMC | M63*2 | 44-37 | 63 | 63-63.2 | 13 | 38 | 64/68 |
| D.M64A-EMC | M64*1.5 | 44-37 | 64 | 64-64.2 | 13 | 38 | 64/68 |
| D.M64B-EMC | M64*2 | 44-37 | 64 | 64-64.2 | 13 | 38 | 64/68 |
| D.M72-EMC | M72*2 | 52-42 | 72 | 72-72.2 | 15 | 42 | 65/68 |
| D.M75-EMC | M75*2 | 52-42 | 75 | 75-75.2 | 15 | 42 | 78 |
| D.M80-EMC | M80*2 | 62-50 | 80 | 80-80.2 | 15 | 45 | 86/88 |
| D.M88-EMC | M88*2 | 70-60 | 88 | 88-88.2 | 15 | 45 | 98 |
| D.M100-EMC | M100*2 | 80-70 | 100 | 100-100.2 | 15 | 45 | 110 |
Model specificationsG/NPT threads
| Model | Thread | Cable diameter range (mm) | Thread outside diameter (mm) | Threads per inch | Thread length GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| D.G1/4-EMC | G1/4 | 6.5-3 | 13.1 | 19 | 7 | 19 | 14 |
| D.G3/8-EMC | G3/8 | 8-4 | 16.6 | 19 | 8 | 19 | 18 |
| D.G1/2-EMC | G1/2 | 12-6 | 20.9 | 14 | 8 | 22 | 22 |
| D.G3/4-EMC | G3/4 | 18-13 | 26.4 | 14 | 9 | 25 | 30 |
| D.G1-EMC | G1 | 25-18 | 33.2 | 11 | 11 | 29 | 40 |
| D.G1-1/4-EMC | G1-1/4 | 33-25 | 41.9 | 11 | 13 | 35 | 50 |
| D.G1-1/2-EMC | G1-1/2 | 38-32 | 47.8 | 11 | 14 | 37 | 57 |
| D.G2-EMC | G2 | 44-37 | 59.6 | 11 | 14 | 38 | 64 |
| D.G2-1/2-EMC | G2-1/2 | 52-42 | 75.1 | 11 | 15 | 38 | 77 |
| D.G3-EMC | G3 | 70-65 | 87.8 | 11 | 15 | 48 | 94 |
| D.NPT1/4-EMC | NPT1/4 | 6.5-3 | 13.6 | 18 | 7 | 19 | 14 |
| D.NPT3/8-EMC | NPT3/8 | 8-4 | 17 | 18 | 8 | 19 | 18 |
| D.NPT1/2-EMC | NPT1/2 | 12-6 | 21.2 | 14 | 8 | 22 | 22 |
| D.NPT3/4-EMC | NPT3/4 | 18-13 | 26.5 | 14 | 9 | 25 | 30 |
| D.NPT1-EMC | NPT1 | 25-18 | 33.2 | 11.5 | 11 | 29 | 40 |
| D.NPT1-1/4-EMC | NPT1-1/4 | 33-25 | 41.9 | 11.5 | 13 | 35 | 50 |
| D.NPT1-1/2-EMC | NPT1-1/2 | 38-32 | 48 | 11.5 | 14 | 37 | 57 |
| D.NPT2-EMC | NPT2 | 44-37 | 60 | 11.5 | 14 | 38 | 64 |
| D.NPT2-1/2-EMC | NPT2-1/2 | 52-42 | 72.6 | 8 | 15 | 38 | 78 |
| D.NPT3-EMC | NPT3 | 70-65 | 88.6 | 8 | 15 | 45 | 98 |
F-Series EMC Cable Gland for Metric Entries
Brass cable entry
F-Series EMC Cable Gland for Metric Entries
Model specificationsF-Series EMC Cable Gland for Metric Entries — thread and cable dimensions
| Model | Thread AG | Cable diameter range (mm) | Spanner size (mm) | Diagonal Size (mm) |
|---|---|---|---|---|
| F.M20A-EMC | M20*1.5 | 6-12 | 22 | 24.5 |
| F.M20B-EMC | M20*1.5 | 5-9 | 22 | 24.6 |
| F.M20C-EMC | M20*1.5 | 10-14 | 24 | 26.6 |
| F.M20D-EMC | M20*1.5 | 7-12 | 24 | 26.6 |
| F.M25A-EMC | M25*1.5 | 13-18 | 30 | 34 |
| F.M25B-EMC | M25*1.5 | 9-16 | 30 | 34 |
| F.M32A-EMC | M32*1.5 | 18-25 | 40 | 44.5 |
| F.M32B-EMC | M32*1.5 | 13-20 | 40 | 44.5 |
| F.M40A-EMC | M40*1.5 | 22-32 | 50 | 55 |
| F.M40B-EMC | M40*1.5 | 20-26 | 50 | 55 |
| F.M50A-EMC | M50*1.5 | 32-38 | 57 | 62 |
| F.M50B-EMC | M50*1.5 | 25-31 | 57 | 62 |
| F.M63A-EMC | M63*1.5 | 37-44 | 65 | 72 |
| F.M63B-EMC | M63*1.5 | 29-35 | 65 | 72 |
BW Cable Gland for Indoor SWA Cable
Brass cable entry
BW Cable Gland for Indoor SWA Cable
Model specificationsBW Cable Gland for Indoor SWA Cable — thread and cable dimensions
| Item Code | Thread Size (Metric) | Thread Size (NPT) | Min. Thread Length D (mm) | Unarmored Cable OD “A” (MIN–MAX, mm) | Armored Cable OD “B” (MIN–MAX, mm) |
|---|---|---|---|---|---|
| BW20S | M20 | 1/2″ | 10 | 11.50 | 15.50 |
| BW20L | M20 | 1/2″ | 10 | 14.00 | 20.50 |
| BW25S | M25 | 3/4″ | 10 | 18.00 | 24.00 |
| BW25L | M25 | 3/4″ | 10 | 20.00 | 27.00 |
| BW32S | M32 | 1″ | 10 | 26.30 | 33.50 |
| BW32L | M32 | 1″ | 10 | 26.30 | 33.50 |
| BW40S | M40 | 1-1/4″ | 13 | 31.50 | 39.50 |
| BW40L | M40 | 1-1/4″ | 13 | 32.00 | 40.00 |
| BW50S | M50 | 1-1/2″ | 13 | 38.20 | 46.30 |
| BW50L | M50 | 2″ | 13 | 44.00 | 52.60 |
| BW63S | M63 | 2″ | 14 | 50.10 | 59.00 |
| BW63L | M63 | 2-1/2″ | 14 | 56.00 | 65.30 |
| BW75S | M75 | 2-1/2″ | 15 | 62.00 | 71.60 |
| BW75L | M75 | 3″ | 15 | 68.00 | 78.00 |
| BW90 | M90 | 3″ | 20 | 80.50 | 91.00 |
CW Single-Compression Cable Gland for SWA
Brass cable entry
CW Single-Compression Cable Gland for SWA
Model specificationsCW Single-Compression Cable Gland for SWA — thread and cable dimensions
| Size Code | Thread outside diameter (mm) | Thread Length (mm) | Unarmored Cable OD “A” (MIN–MAX, mm) | Armored Cable OD “B” (MIN–MAX, mm) | Clamping Range (mm) | Wrench Size (mm) | Max Product OD (mm) |
|---|---|---|---|---|---|---|---|
| CW-20S | 20 | 10 | 6.0 – 10.0 | 8.0 – 15.8 | 0.9 / 1.25 | 24 | 27 |
| CW-20M | 20 | 10 | 8.0 – 11.8 | 12.9 – 17.2 | 0.9 / 1.25 | 27 | 30 |
| CW-20L | 20 | 10 | 11.0 – 14.0 | 15.5 – 20.8 | 0.9 / 1.25 | 30 | 33 |
| CW-25S | 25 | 10 | 12.0 – 17.0 | 17.5 – 24.0 | 1.25 / 1.60 | 34 | 36 |
| CW-25L | 25 | 10 | 13.0 – 20.3 | 24.0 – 26.5 | 1.25 / 1.60 | 36 | 39 |
| CW-32S | 32 | 12 | 17.0 – 24.0 | 25.0 – 32.0 | 1.60 / 2.00 | 44 | 46 |
| CW-32L | 32 | 12 | 19.0 – 26.2 | 26.7 – 34.0 | 1.60 / 2.00 | 46 | 48.5 |
| CW-40S | 40 | 14 | 23.0 – 27.0 | 31.0 – 37.0 | 1.60 / 2.00 | 52 | 57 |
| CW-40L | 40 | 14 | 25.0 – 32.2 | 33.0 – 40.5 | 1.60 / 2.00 | 55 | 58.5 |
| CW-50S | 50 | 15 | 31.5 – 37.0 | 39.4 – 45.0 | 2.00 / 2.50 | 58 | 65 |
| CW-50L | 50 | 15 | 36.5 – 42.0 | 45.7 – 50.0 | 2.00 / 2.50 | 65 | 72 |
| CW-63S | 63 | 15 | 42.5 – 47.0 | 52.1 – 56.0 | 2.5 | 68 | 75 |
| CW-63L | 63 | 15 | 49.1 – 56.0 | 58.4 – 66.0 | 2.5 | 80 | 89 |
| CW-75S | 75 | 15 | 54.5 – 58.0 | 64.8 – 68.0 | 2.5 | 82 | 90 |
| CW-75L | 75 | 15 | 57.5 – 64.0 | 68.0 – 74.0 | 2.5 | 92 | 103 |
| CW-90S | 90 | 15 | 66.0 – 76.0 | 77.0 – 86.0 | 2.50 / 3.15 | 106 | 118 |
| CW-90L | 90 | 15 | 66.0 – 79.0 | 77.0 – 90.0 | 2.50 / 3.15 | 106 | 118 |
| CW-100 | 100 | 17 | 80.0 – 90.9 | 92.0 – 101.5 | 3.15 / 4.00 | 123 | 135.3 |
| CW-115 | 115 | 17 | 87.0 – 97.9 | 101.0 – 110.3 | 3.15 / 4.00 | 133.4 | 146.7 |
Ex-VII Double-Seal Armoured Cable Gland
Brass cable entry
Ex-VII Double-Seal Armoured Cable Gland
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M16 × 1.5 | Ex-VIIM16 | 5-16 | 12 | 15 | 16 | 24 |
| M20 × 1.5 | Ex-VIIM20 | 5-16 | 12 | 15 | 20 | 24 |
| M20 × 1.5D | Ex-VIIM20D | 9-20 | 16 | 15 | 20 | 30 |
| M25 × 1.5 | Ex-VIIM25 | 9-20 | 16 | 15 | 25 | 30 |
| M25 × 1.5D | Ex-VIIM25D | 14-26 | 20 | 15 | 25 | 38 |
| M32 × 1.5 | Ex-VIIM32 | 14-26 | 20 | 17 | 32 | 38 |
| M32 × 1.5D | Ex-VIIM32D | 18-33 | 28 | 17 | 32 | 45 |
| M40 × 1.5 | Ex-VIIM40-33 | 18-33 | 28 | 17 | 40 | 45 |
| M40 × 1.5D | Ex-VIIM40D | 20-40 | 35 | 17 | 40 | 55 |
| M50 × 1.5 | Ex-VIIM50 | 20-40 | 35 | 20 | 50 | 55 |
| M50 × 1.5D | Ex-VIIM50D | 26-50 | 45 | 20 | 50 | 68 |
| M63 × 1.5 | Ex-VIIM63 | 26-50 | 45 | 20 | 63 | 68 |
| M63 × 1.5D | Ex-VIIM63D | 30-64 | 55 | 20 | 63 | 82 |
| M75 × 2 | Ex-VIIM75 | 30-64 | 55 | 22 | 75 | 82 |
| M88 × 2 | Ex-VIIM88 | 36-80 | 70 | 22 | 88 | 98 |
| M100 × 2 | Ex-VIIM100 | 41-90 | 80 | 22 | 100 | 110 |
| M115 × 2 | Ex-VIIM115 | 47-103 | 90 | 22 | 115 | 125 |
| M130 × 2 | Ex-VIIM130 | 63-119 | 100 | 22 | 130 | 140 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| NPT 3/8 | Ex-VIINPT3/8 | 5-16 | 12 | 15 | 17.05 | 24 |
| NPT 1/2 | Ex-VIINPT1/2 | 5-16 | 12 | 15 | 21.22 | 24 |
| NPT 1/2D | Ex-VIINPT1/2D | 9-20 | 16 | 15 | 21.22 | 30 |
| NPT 3/4 | Ex-VIINPT3/4 | 9-20 | 16 | 15 | 26.56 | 30 |
| NPT 3/4D | Ex-VIINPT3/4D | 14-26 | 20 | 15 | 26.56 | 38 |
| NPT 1 | Ex-VIINPT1 | 14-26 | 20 | 17 | 33.28 | 38 |
| NPT 1D | Ex-VIINPT1D | 18-33 | 28 | 17 | 33.28 | 45 |
| NPT 1-1/4 | Ex-VIINPT1-1/4 | 18-33 | 28 | 17 | 41.98 | 45 |
| NPT 1-1/4D | Ex-VIINPT1-1/4D | 20-40 | 35 | 17 | 41.98 | 55 |
| NPT 1-1/2 | Ex-VIINPT1-1/2 | 20-40 | 35 | 20 | 48.05 | 55 |
| NPT 1-1/2D | Ex-VIINPT1-1/2D | 26-50 | 45 | 20 | 48.05 | 68 |
| NPT 2 | Ex-VIINPT2 | 26-50 | 45 | 20 | 60.09 | 68 |
| NPT 2D | Ex-VIINPT2D | 30-64 | 55 | 20 | 60.09 | 82 |
| NPT 2-1/2 | Ex-VIINPT2-1/2 | 30-64 | 55 | 22 | 72.69 | 82 |
| NPT 3 | Ex-VIINPT3 | 36-80 | 70 | 22 | 88.60 | 98 |
| NPT 4 | Ex-VIINPT4 | 47-103 | 90 | 22 | 113.97 | 125 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| G 3/8 | Ex-VIIG3/8 | 5-16 | 12 | 15 | 16.66 | 24 |
| G 1/2 | Ex-VIIG1/2 | 5-16 | 12 | 15 | 20.95 | 24 |
| G 1/2D | Ex-VIIG1/2D | 9-20 | 16 | 15 | 20.95 | 30 |
| G 3/4 | Ex-VIIG3/4 | 9-20 | 16 | 15 | 26.44 | 30 |
| G 3/4D | Ex-VIIG3/4D | 14-26 | 20 | 15 | 26.44 | 38 |
| G 1 | Ex-VIIG1 | 14-26 | 20 | 17 | 33.25 | 38 |
| G 1D | Ex-VIIG1D | 18-33 | 28 | 17 | 33.25 | 45 |
| G 1-1/4 | Ex-VIIG1-1/4 | 18-33 | 28 | 17 | 41.91 | 45 |
| G 1-1/4D | Ex-VIIG1-1/4D | 20-40 | 35 | 17 | 41.91 | 55 |
| G 1-1/2 | Ex-VIIG1-1/2 | 20-40 | 35 | 20 | 47.80 | 55 |
| G 1-1/2D | Ex-VIIG1-1/2D | 26-50 | 45 | 20 | 47.80 | 68 |
| G 2 | Ex-VIIG2 | 26-50 | 45 | 20 | 59.61 | 68 |
| G 2D | Ex-VIIG2D | 30-64 | 55 | 20 | 59.61 | 82 |
| G 2-1/2 | Ex-VIIG2-1/2 | 30-64 | 55 | 22 | 75.18 | 82 |
| G 3 | Ex-VIIG3 | 36-80 | 70 | 22 | 87.88 | 98 |
| G 4 | Ex-VIIG4 | 47-103 | 90 | 22 | 113.03 | 125 |
Ex-B Cable Gland for Unarmoured Cable
Brass cable entry
Ex-B Cable Gland for Unarmoured Cable
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M10 × 1.5 | Ex-BM10-6.2 | 3-6.2 | 12 | 10 | 14/14 |
| M12 × 1.5 | Ex-BM12-6.2 | 3-6.2 | 12 | 12 | 14/14 |
| M12 × 1.5 | Ex-BM12-8 | 4-8 | 12 | 12 | 18/18 |
| M14 × 1.5 | Ex-BM14-8 | 4-8 | 12 | 14 | 18/18 |
| M16 × 1.5 | Ex-BM16-8 | 4-8 | 12 | 16 | 18/18 |
| M16 × 1.5 | Ex-BM16-10 | 5-10 | 12 | 16 | 22/22 |
| M18 × 1.5 | Ex-BM18-10 | 5-10 | 12 | 18 | 22/22 |
| M20 × 1.5 | Ex-BM20-10 | 5-10 | 12 | 20 | 22/24 |
| M20 × 1.5 | Ex-BM20-12 | 8-12 | 12 | 20 | 24/24 |
| M20 × 1.5 | Ex-BM20-14 | 10-14 | 12 | 20 | 26/26 |
| M22 × 1.5 | Ex-BM22-14 | 10-14 | 12 | 22 | 26/26 |
| M24 × 1.5 | Ex-BM24-14 | 10-14 | 12 | 24 | 26/26 |
| M25 × 1.5 | Ex-BM25-12 | 8-12 | 12 | 25 | 24/30 |
| M25 × 1.5 | Ex-BM25-14 | 10-14 | 12 | 25 | 26/30 |
| M25 × 1.5 | Ex-BM25-18 | 13-18 | 12 | 25 | 32/32 |
| M27 × 1.5 | Ex-BM27-18 | 13-18 | 12 | 27 | 32/32 |
| M30 × 1.5 | Ex-BM30-18 | 13-18 | 12 | 30 | 32/32 |
| M32 × 1.5 | Ex-BM32-25 | 18-25 | 15 | 32 | 40/40 |
| M36 × 1.5 | Ex-BM36-25 | 18-25 | 15 | 36 | 40/40 |
| M40 × 1.5 | Ex-BM40-32 | 25-32 | 15 | 40 | 50/50 |
| M48 × 1.5 | Ex-BM48-32 | 25-32 | 15 | 48 | 50/50 |
| M50 × 1.5 | Ex-BM50-39 | 32-39 | 15 | 50 | 60/60 |
| M60 × 1.5 | Ex-BM60-44 | 36-44 | 15 | 60 | 65/65 |
| M63 × 1.5 | Ex-BM63-44 | 36-44 | 15 | 63 | 65/68 |
| M63 × 1.5 | Ex-BM63-54 | 45-54 | 15 | 63 | 75/75 |
| M64 × 2.0 | Ex-BM64-54 | 45-54 | 15 | 64 | 75/75 |
| M72 × 1.5 | Ex-BM72-54 | 45-54 | 20 | 72 | 80/80 |
| M75 × 2.0 | Ex-BM75-66 | 55-66 | 20 | 75 | 85/90 |
| M78 × 2.0 | Ex-BM78-66 | 55-66 | 20 | 78 | 90/90 |
| M80 × 2.0 | Ex-BM80-66 | 55-66 | 20 | 80 | 90/90 |
| M88 × 2.0 | Ex-BM88-77 | 67-77 | 20 | 88 | 100/100 |
| M90 × 2.0 | Ex-BM90-77 | 67-77 | 20 | 90 | 100/100 |
| M100 × 2.0 | Ex-BM100-87 | 78-87 | 20 | 100 | 110/110 |
| M110 × 2.0 | Ex-BM110-99 | 88-99 | 20 | 110 | 120/120 |
| M120 × 2.0 | Ex-BM120-108 | 99-108 | 20 | 120 | 130/130 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| NPT 1/4 | Ex-BNPT1/4-8 | 4-8 | 12 | 13.61 | 18/18 |
| NPT 3/8 | Ex-BNPT3/8-10 | 6-10 | 12 | 17.05 | 22/22 |
| NPT 1/2S | Ex-BNPT1/2S-12 | 8-12 | 12 | 21.22 | 24/24 |
| NPT 1/2D | Ex-BNPT1/2D-14 | 10-14 | 12 | 21.22 | 26/26 |
| NPT 3/4 | Ex-BNPT3/4-10 | 6-10 | 12 | 26.56 | 22/32 |
| NPT 3/4 | Ex-BNPT3/4-14 | 10-14 | 12 | 26.56 | 26/32 |
| NPT 3/4 | Ex-BNPT3/4-18 | 13-18 | 12 | 26.56 | 32/32 |
| NPT 1 | Ex-BNPT1-25 | 18-25 | 15 | 33.28 | 40/40 |
| NPT 1-1/4 | Ex-BNPT1-1/4-32 | 25-32 | 15 | 41.98 | 50/50 |
| NPT 1-1/2 | Ex-BNPT1-1/2-32 | 25-32 | 15 | 48.05 | 50/52 |
| NPT 1-1/2 | Ex-BNPT1-1/2-39 | 32-39 | 15 | 48.05 | 52/52 |
| NPT 2S | Ex-BNPT2S-44 | 37-44 | 15 | 60.09 | 65/65 |
| NPT 2-1/2 | Ex-BNPT2-1/2-54 | 44-54 | 20 | 72.69 | 75/85 |
| NPT 2-1/2 | Ex-BNPT2-1/2-66 | 54-66 | 20 | 72.69 | 85/85 |
| NPT 3S | Ex-BNPT3S-77 | 66-77 | 20 | 88.60 | 100/100 |
| NPT 4S | Ex-BNPT4S-99 | 88-99 | 20 | 113.97 | 122/122 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| G 1/4 | Ex-BG1/4-8 | 4-8 | 12 | 13.15 | 18/18 |
| G 3/8 | Ex-BG3/8-10 | 6-10 | 12 | 16.66 | 22/22 |
| G 1/2S | Ex-BG1/2S-12 | 8-12 | 12 | 20.95 | 24/24 |
| G 1/2D | Ex-BG1/2D-14 | 10-14 | 12 | 20.95 | 26/26 |
| G 3/4 | Ex-BG3/4-10 | 6-10 | 12 | 26.44 | 22/32 |
| G 3/4 | Ex-BG3/4-14 | 10-14 | 12 | 26.44 | 26/32 |
| G 3/4 | Ex-BG3/4-18 | 13-18 | 12 | 26.44 | 32/32 |
| G 1 | Ex-BG1-25 | 18-25 | 15 | 33.25 | 40/40 |
| G 1-1/4 | Ex-BG1-1/4-32 | 25-32 | 15 | 41.91 | 50/50 |
| G 1-1/2 | Ex-BG1-1/2-32 | 25-32 | 15 | 47.80 | 50/52 |
| G 1-1/2 | Ex-BG1-1/2-39 | 32-39 | 15 | 47.80 | 52/52 |
| G 2 | Ex-BG2S-44 | 37-44 | 15 | 59.61 | 65/65 |
| G 2-1/2 | Ex-BG2-1/2-54 | 44-54 | 20 | 75.18 | 75/85 |
| G 2-1/2 | Ex-BG2-1/2-66 | 54-66 | 20 | 75.18 | 85/85 |
| G 3 | Ex-BG3S-77 | 66-77 | 20 | 87.88 | 100/100 |
| G 4 | Ex-BG4S-99 | 88-99 | 20 | 113.03 | 122/122 |
Ex-V Single-Seal Armoured Cable Gland
Brass cable entry
Ex-V Single-Seal Armoured Cable Gland
Model specificationsEx-V — thread and cable dimensions
| Metric thread | Metric model | G/NPT thread size | NPT model | G model | Cable range B (mm) | Cable range A (mm) | H (mm) | L (mm) | Across flats (mm) | Across corners (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
| M16*1.5 | Ex-V08-M16 | 3/8″ | Ex-V08-NPT3/8 | Ex-V08-G3/8 | 5-8 | 3-6 | 30 | 12 | 24 | 28 |
| M16*1.5 | Ex-V10-M16 | 3/8″ | Ex-V10-NPT3/8 | Ex-V10-G3/8 | 6-10 | 4-8 | 30 | 12 | 24 | 28 |
| M20*1.5 | Ex-V14-M20 | 1/2″ | Ex-V14-NPT1/2 | Ex-V14-G1/2 | 9-14 | 6-11 | 30 | 12 | 24 | 28 |
| M20*1.5 | Ex-V16-M20 | 1/2″ | Ex-V16-NPT1/2 | Ex-V16-G1/2 | 10-16 | 7-12 | 30 | 12 | 24 | 28 |
| M20*1.5 | Ex-V18-M20 | 1/2″ | Ex-V18-NPT1/2 | Ex-V18-G1/2 | 13-18 | 9-14 | 32 | 12 | 30 | 35 |
| M25*1.5 | Ex-V21-M25 | 3/4″ | Ex-V21-NPT3/4 | Ex-V21-G3/4 | 15-21 | 11-17 | 35 | 13 | 36 | 42 |
| M25*1.5 | Ex-V24-M25 | 3/4″ | Ex-V24-NPT3/4 | Ex-V24-G3/4 | 17-24 | 13-20 | 35 | 13 | 40 | 47 |
| M32*1.5 | Ex-V28-M32 | 1″ | Ex-V28-NPT1 | Ex-V28-G1 | 20-28 | 16-23 | 39 | 15 | 46 | 53 |
| M32*1.5 | Ex-VK2-M32 | 1″ | Ex-V32-NPT1 | Ex-V32-G1 | 23-32 | 18-26 | 39 | 15 | 46 | 53 |
| M40*1.5 | Ex-V35-M40 | 1-1/4″ | Ex-V35-NPT1-1/4 | Ex-V35-G1-1/4 | 26-35 | 21-29 | 43 | 15 | 55 | 64 |
| M40*1.5 | Ex-V38-M40 | 1-1/4″ | Ex-V38-NPT1-1/4 | Ex-V38-G1-1/4 | 31-38 | 25-32 | 43 | 15 | 55 | 64 |
| M50*1.5 | Ex-V41-M50 | 1-1/2″ | Ex-V41-NPT1-1/2 | Ex-V41-G1-1/2 | 34-41 | 28-35 | 48 | 15 | 65 | 75 |
| M50*1.5 | Ex-V44-M50 | 1-1/2″ | Ex-V44-NPT1-1/2 | Ex-V44-G1-1/2 | 37-44 | 31-38 | 48 | 15 | 65 | 75 |
| M63*1.5 | Ex-V50-M63 | 2″ | Ex-V50-NPT2 | Ex-V50-G2 | 40-50 | 33-43 | 53 | 16 | 80 | 92 |
| M63*1.5 | Ex-V55-M63 | 2″ | Ex-V55-NPT2 | Ex-V55-G2 | 43-55 | 36-47 | 53 | 16 | 80 | 92 |
| M75*1.5 | Ex-V63-M75 | 2-1/2″ | Ex-V63-NPT2-1/2 | Ex-V63-G2 | 50-63 | 42-53 | 58 | 16 | 96 | 111 |
| M75*1.5 | Ex-V68-M75 | 2-1/2″ | Ex-V68-NPT2-1/2 | Ex-V68-G2-1/2 | 54-68 | 45-58 | 58 | 16 | 96 | 111 |
| M88*2 | Ex-V72-M88 | 3″ | Ex-V72-NPT3 | Ex-V72-G3 | 62-72 | 52-62 | 64 | 18 | 114 | 134 |
| M88*2 | Ex-V79-M88 | 3″ | Ex-V79-NPT3 | Ex-V79-G3 | 67-79 | 56-67 | 64 | 18 | 114 | 134 |
| M110,2 | Ex-V89-M110 | 4″ | Ex-V89-NPT4 | Ex-V89-G4 | 78-89 | 65-75 | 70 | 18 | 128 | 148 |
| M110,2 | Ex-V105-M110 | 4″ | Ex-V105-NPT4 | Ex-V105-G4 | 38-104.5 | 74-91 | 70 | 18 | 138 | 148 |
Ex-VI Clamping Gland for Unarmoured Cable
Brass cable entry
Ex-VI Clamping Gland for Unarmoured Cable
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M16 × 1.5 | Ex-VIM16 | 8-14 | 15 | 16 | 24 |
| M20 × 1.5 | Ex-VIM20 | 8-14 | 15 | 20 | 24 |
| M25 × 1.5 | Ex-VIM25 | 8-17 | 15 | 25 | 30 |
| M32 × 1.5 | Ex-VIM32 | 12-24 | 17 | 32 | 38 |
| M40 × 1.5 | Ex-VIM40 | 18-30 | 17 | 40 | 45 |
| M50 × 1.5 | Ex-VIM50 | 24-36 | 20 | 50 | 55 |
| M63 × 1.5 | Ex-VIM63 | 30-46 | 20 | 63 | 68 |
| M75 × 2.0 | Ex-VIM75 | 36-60 | 22 | 75 | 80 |
| M88 × 2.0 | Ex-VIM88 | 58-72 | 22 | 88 | 96 |
| M110 × 2.0 | Ex-VIM110 | 66-90 | 22 | 110 | 125 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| NPT 3/8 | Ex-VINPT3/8 | 8-14 | 15 | 17.05 | 24 |
| NPT 1/2 | Ex-VINPT1/2 | 8-14 | 15 | 21.22 | 24 |
| NPT 3/4 | Ex-VINPT3/4 | 8-17 | 15 | 26.56 | 30 |
| NPT 1 | Ex-VINPT1 | 12-24 | 17 | 33.28 | 38 |
| NPT 1-1/4 | Ex-VINPT1-1/4 | 18-30 | 17 | 41.98 | 45 |
| NPT 1-1/2 | Ex-VINPT1-1/2 | 24-36 | 20 | 48.05 | 55 |
| NPT 2 | Ex-VINPT2 | 30-46 | 20 | 60.09 | 68 |
| NPT 2-1/2 | Ex-VINPT2-1/2 | 36-60 | 22 | 72.69 | 80 |
| NPT 3 | Ex-VINPT3 | 58-72 | 22 | 88.60 | 96 |
| NPT 4 | Ex-VINPT4 | 66-90 | 22 | 113.97 | 125 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| G 3/8 | Ex-VIG3/8 | 8-14 | 15 | 16.66 | 24 |
| G 1/2 | Ex-VIG1/2 | 8-14 | 15 | 20.95 | 24 |
| G 3/4 | Ex-VIG3/4 | 8-17 | 15 | 26.44 | 30 |
| G 1 | Ex-VIG1 | 12-24 | 17 | 33.25 | 38 |
| G 1-1/4 | Ex-VIG1-1/4 | 18-30 | 17 | 41.91 | 45 |
| G 1-1/2 | Ex-VIG1-1/2 | 24-36 | 20 | 47.80 | 55 |
| G 2 | Ex-VIG2 | 30-46 | 20 | 59.61 | 68 |
| G 2-1/2 | Ex-VIG2-1/2 | 36-60 | 22 | 75.18 | 80 |
| G 3 | Ex-VIG3 | 58-72 | 22 | 87.88 | 96 |
| G 4 | Ex-VIG4 | 66-90 | 22 | 113.03 | 125 |
Ex-VIG Clamping Gland for Unarmoured Cable
Brass cable entry
Ex-VIG Clamping Gland for Unarmoured Cable
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M16 × 1.5 | Ex-VIGM16 | 8-14 | 15 | 16 | 24 |
| M20 × 1.5 | Ex-VIGM20 | 5-14 | 15 | 20 | 24 |
| M25 × 1.5 | Ex-VIGM25 | 5-17 | 15 | 25 | 30 |
| M32 × 1.5 | Ex-VIGM32 | 8-24 | 17 | 32 | 38 |
| M40 × 1.5 | Ex-VIGM40 | 10-30 | 17 | 40 | 45 |
| M50 × 1.5 | Ex-VIGM50 | 12-36 | 20 | 50 | 55 |
| M63 × 1.5 | Ex-VIGM63 | 18-46 | 20 | 63 | 68 |
| M75 × 2.0 | Ex-VIGM75 | 20-60 | 22 | 75 | 80 |
| M88 × 2.0 | Ex-VIGM88 | 22-72 | 22 | 88 | 96 |
| M110 × 2.0 | Ex-VIGM110 | 30-90 | 22 | 110 | 125 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| NPT 3/8 | Ex-VIGNPT3/8 | 8-14 | 15 | 17.05 | 24 |
| NPT 1/2 | Ex-VIGNPT1/2 | 5-14 | 15 | 21.22 | 24 |
| NPT 3/4 | Ex-VIGNPT3/4 | 5-17 | 15 | 26.56 | 30 |
| NPT 1 | Ex-VIGNPT1 | 8-24 | 17 | 33.28 | 38 |
| NPT 1-1/4 | Ex-VIGNPT1-1/4 | 10-30 | 17 | 41.98 | 45 |
| NPT 1 1/2 | Ex-VIGNPT1-1/2 | 12-36 | 20 | 48.05 | 55 |
| NPT 2 | Ex-VIGNPT2 | 18-46 | 20 | 60.09 | 68 |
| NPT 2-1/2 | Ex-VIGNPT2-1/2 | 20-60 | 22 | 72.69 | 80 |
| NPT 3 | Ex-VIGNPT3 | 22-72 | 22 | 88.60 | 96 |
| NPT 4 | Ex-VIGNPT4 | 30-90 | 22 | 113.97 | 125 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| G 3/8 | Ex-VIGG3/8 | 8-14 | 15 | 16.66 | 24 |
| G 1/2 | Ex-VIGG1/2 | 5-14 | 15 | 20.95 | 24 |
| G 3/4 | Ex-VIGG3/4 | 5-17 | 15 | 26.44 | 30 |
| G 1 | Ex-VIGG1 | 8-24 | 17 | 33.25 | 38 |
| G 1-1/4 | Ex-VIGG1-1/4 | 10-30 | 17 | 41.91 | 45 |
| G 1-1/2 | Ex-VIGG1-1/2 | 12-36 | 20 | 47.80 | 55 |
| G 2 | Ex-VIGG2 | 18-46 | 20 | 59.61 | 68 |
| G 2-1/2 | Ex-VIGG2-1/2 | 20-60 | 22 | 75.18 | 80 |
| G 3 | Ex-VIGG3 | 22-72 | 22 | 87.88 | 96 |
| G 4 | Ex-VIGG4 | 30-90 | 22 | 113.03 | 125 |
Ex-VIIIG Single-Seal Armoured Cable Gland
Brass cable entry
Ex-VIIIG Single-Seal Armoured Cable Gland
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M16 × 1.5 | Ex-VIIIGM16 | 5-16 | 12 | 15 | 16 | 24 |
| M20 × 1.5 | Ex-VIIIGM20 | 5-16 | 12 | 15 | 20 | 24 |
| M20 × 1.5D | Ex-VIIIGM20D | 9-20 | 16 | 15 | 20 | 30 |
| M25 × 1.5 | Ex-VIIIGM25 | 9-20 | 16 | 15 | 25 | 30 |
| M25 × 1.5D | Ex-VIIIGM25D | 14-26 | 20 | 15 | 25 | 38 |
| M32 × 1.5 | Ex-VIIIGM32 | 14-26 | 20 | 17 | 32 | 38 |
| M32 × 1.5D | Ex-VIIIGM32D | 18-33 | 28 | 17 | 32 | 45 |
| M40 × 1.5 | Ex-VIIIGM40-33 | 18-33 | 28 | 17 | 40 | 45 |
| M40 × 1.5D | Ex-VIIIGM40D | 20-40 | 35 | 17 | 40 | 55 |
| M50 × 1.5 | Ex-VIIIGM50 | 20-40 | 35 | 20 | 50 | 55 |
| M50 × 1.5D | Ex-VIIIGM50D | 26-50 | 45 | 20 | 50 | 68 |
| M63 × 1.5 | Ex-VIIIGM63 | 26-50 | 45 | 20 | 63 | 68 |
| M63 × 1.5D | Ex-VIIIGM63D | 30-64 | 55 | 20 | 63 | 82 |
| M75 × 2 | Ex-VIIIGM75 | 30-64 | 55 | 22 | 75 | 82 |
| M88 × 2 | Ex-VIIIGM88 | 36-80 | 70 | 22 | 88 | 98 |
| M100 × 2 | Ex-VIIIGM100 | 41-90 | 80 | 22 | 100 | 110 |
| M115 × 2 | Ex-VIIIGM115 | 47-103 | 90 | 22 | 115 | 125 |
| M130 × 2 | Ex-VIIIGM130 | 63-119 | 100 | 22 | 130 | 140 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| NPT 3/8 | Ex-VIIIGNPT3/8 | 5-16 | 12 | 15 | 17.05 | 24 |
| NPT 1/2 | Ex-VIIIGNPT1/2 | 5-16 | 12 | 15 | 21.22 | 24 |
| NPT 1/2D | Ex-VIIIGNPT1/2D | 9-20 | 16 | 15 | 21.22 | 30 |
| NPT 3/4 | Ex-VIIIGNPT3/4 | 9-20 | 16 | 15 | 26.56 | 30 |
| NPT 3/4D | Ex-VIIIGNPT3/4D | 14-26 | 20 | 15 | 26.56 | 38 |
| NPT 1 | Ex-VIIIGNPT1 | 14-26 | 20 | 17 | 33.28 | 38 |
| NPT 1D | Ex-VIIIGNPT1D | 18-33 | 28 | 17 | 33.28 | 45 |
| NPT 1-1/4 | Ex-VIIIGNPT1-1/4 | 18-33 | 28 | 17 | 41.98 | 45 |
| NPT 1-1/4D | Ex-VIIIGNPT1-1/4D | 20-40 | 35 | 17 | 41.98 | 55 |
| NPT 1-1/2 | Ex-VIIIGNPT1-1/2 | 20-40 | 35 | 20 | 48.05 | 55 |
| NPT 1-1/2D | Ex-VIIIGNPT1-1/2D | 26-50 | 45 | 20 | 48.05 | 68 |
| NPT 2 | Ex-VIIIGNPT2 | 26-50 | 45 | 20 | 60.09 | 68 |
| NPT 2D | Ex-VIIIGNPT2D | 30-64 | 55 | 20 | 60.09 | 82 |
| NPT 2-1/2 | Ex-VIIIGNPT2-1/2 | 30-64 | 55 | 22 | 72.69 | 82 |
| NPT 3 | Ex-VIIIGNPT3 | 36-80 | 70 | 22 | 88.60 | 98 |
| NPT 4 | Ex-VIIIGNPT4 | 47-103 | 90 | 22 | 113.97 | 125 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| G 3/8 | Ex-VIIIGG3/8 | 5-16 | 12 | 15 | 16.66 | 24 |
| G 1/2 | Ex-VIIIGG1/2 | 5-16 | 12 | 15 | 20.95 | 24 |
| G 1/2D | Ex-VIIIGG1/2D | 9-20 | 16 | 15 | 20.95 | 30 |
| G 3/4 | Ex-VIIIGG3/4 | 9-20 | 16 | 15 | 26.44 | 30 |
| G 3/4D | Ex-VIIIGG3/4D | 14-26 | 20 | 15 | 26.44 | 38 |
| G 1 | Ex-VIIIGG1 | 14-26 | 20 | 17 | 33.25 | 38 |
| G 1D | Ex-VIIIGG1D | 18-33 | 28 | 17 | 33.25 | 45 |
| G 1-1/4 | Ex-VIIIGG1-1/4 | 18-33 | 28 | 17 | 41.91 | 45 |
| G 1-1/4D | Ex-VIIIGG1-1/4D | 20-40 | 35 | 17 | 41.91 | 55 |
| G 1-1/2 | Ex-VIIIGG1-1/2 | 20-40 | 35 | 20 | 47.80 | 55 |
| G 1-1/2D | Ex-VIIIGG1-1/2D | 26-50 | 45 | 20 | 47.80 | 68 |
| G 2 | Ex-VIIIGG2 | 26-50 | 45 | 20 | 59.61 | 68 |
| G 2D | Ex-VIIIGG2D | 30-64 | 55 | 20 | 59.61 | 82 |
| G 2-1/2 | Ex-VIIIGG2-1/2 | 30-64 | 55 | 22 | 75.18 | 82 |
| G 3 | Ex-VIIIGG3 | 36-80 | 70 | 22 | 87.88 | 98 |
| G 4 | Ex-VIIIGG4 | 47-103 | 90 | 22 | 113.03 | 125 |
Ex-VIIG Double-Seal Armoured Cable Gland
Brass cable entry
Ex-VIIG Double-Seal Armoured Cable Gland
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M16 × 1.5 | Ex-VIIGM16 | 5-16 | 12 | 15 | 16 | 24 |
| M20 × 1.5 | Ex-VIIGM20 | 5-16 | 12 | 15 | 20 | 24 |
| M20 × 1.5D | Ex-VIIGM20D | 9-20 | 16 | 15 | 20 | 30 |
| M25 × 1.5 | Ex-VIIGM25 | 9-20 | 16 | 15 | 25 | 30 |
| M25 × 1.5D | Ex-VIIGM25D | 14-26 | 20 | 15 | 25 | 38 |
| M32 × 1.5 | Ex-VIIGM32 | 14-26 | 20 | 17 | 32 | 38 |
| M32 × 1.5D | Ex-VIIGM32D | 18-33 | 28 | 17 | 32 | 45 |
| M40 × 1.5 | Ex-VIIGM40-33 | 18-33 | 28 | 17 | 40 | 45 |
| M40 × 1.5D | Ex-VIIGM40D | 20-40 | 35 | 17 | 40 | 55 |
| M50 × 1.5 | Ex-VIIGM50 | 20-40 | 35 | 20 | 50 | 55 |
| M50 × 1.5D | Ex-VIIGM50D | 26-50 | 45 | 20 | 50 | 68 |
| M63 × 1.5 | Ex-VIIGM63 | 26-50 | 45 | 20 | 63 | 68 |
| M63 × 1.5D | Ex-VIIGM63D | 30-64 | 55 | 20 | 63 | 82 |
| M75 × 2 | Ex-VIIGM75 | 30-64 | 55 | 22 | 75 | 82 |
| M88 × 2 | Ex-VIIGM88 | 36-80 | 70 | 22 | 88 | 98 |
| M100 × 2 | Ex-VIIGM100 | 41-90 | 80 | 22 | 100 | 110 |
| M115 × 2 | Ex-VIIGM115 | 47-103 | 90 | 22 | 115 | 125 |
| M130 × 2 | Ex-VIIGM130 | 63-119 | 100 | 22 | 130 | 140 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| NPT 3/8 | Ex-VIIGNPT3/8 | 5-16 | 12 | 15 | 17.05 | 24 |
| NPT 1/2 | Ex-VIIGNPT1/2 | 5-16 | 12 | 15 | 21.22 | 24 |
| NPT 1/2D | Ex-VIIGNPT1/2D | 9-20 | 16 | 15 | 21.22 | 30 |
| NPT 3/4 | Ex-VIIGNPT3/4 | 9-20 | 16 | 15 | 26.56 | 30 |
| NPT 3/4D | Ex-VIIGNPT3/4D | 14-26 | 20 | 15 | 26.56 | 38 |
| NPT 1 | Ex-VIIGNPT1 | 14-26 | 20 | 17 | 33.28 | 38 |
| NPT 1D | Ex-VIIGNPT1D | 18-33 | 28 | 17 | 33.28 | 45 |
| NPT 1-1/4 | Ex-VIIGNPT1-1/4 | 18-33 | 28 | 17 | 41.98 | 45 |
| NPT 1-1/4D | Ex-VIIGNPT1-1/4D | 20-40 | 35 | 17 | 41.98 | 55 |
| NPT 1-1/2 | Ex-VIIGNPT1-1/2 | 20-40 | 35 | 20 | 48.05 | 55 |
| NPT 1-1/2D | Ex-VIIGNPT1-1/2D | 26-50 | 45 | 20 | 48.05 | 68 |
| NPT 2 | Ex-VIIGNPT2 | 26-50 | 45 | 20 | 60.09 | 68 |
| NPT 2D | Ex-VIIGNPT2D | 30-64 | 55 | 20 | 60.09 | 82 |
| NPT 2-1/2 | Ex-VIIGNPT2-1/2 | 30-64 | 55 | 22 | 72.69 | 82 |
| NPT 3 | Ex-VIIGNPT3 | 36-80 | 70 | 22 | 88.60 | 98 |
| NPT 4 | Ex-VIIGNPT4 | 47-103 | 90 | 22 | 113.97 | 125 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| G 3/8 | Ex-VIIGG3/8 | 5-16 | 12 | 15 | 16.66 | 24 |
| G 1/2 | Ex-VIIGG1/2 | 5-16 | 12 | 15 | 20.95 | 24 |
| G 1/2D | Ex-VIIGG1/2D | 9-20 | 16 | 15 | 20.95 | 30 |
| G 3/4 | Ex-VIIGG3/4 | 9-20 | 16 | 15 | 26.44 | 30 |
| G 3/4D | Ex-VIIGG3/4D | 14-26 | 20 | 15 | 26.44 | 38 |
| G 1 | Ex-VIIGG1 | 14-26 | 20 | 17 | 33.25 | 38 |
| G 1D | Ex-VIIGG1D | 18-33 | 28 | 17 | 33.25 | 45 |
| G 1-1/4 | Ex-VIIGG1-1/4 | 18-33 | 28 | 17 | 41.91 | 45 |
| G 1-1/4D | Ex-VIIGG1-1/4D | 20-40 | 35 | 17 | 41.91 | 55 |
| G 1-1/2 | Ex-VIIGG1-1/2 | 20-40 | 35 | 20 | 47.80 | 55 |
| G 1-1/2D | Ex-VIIGG1-1/2D | 26-50 | 45 | 20 | 47.80 | 68 |
| G 2 | Ex-VIIGG2 | 26-50 | 45 | 20 | 59.61 | 68 |
| G 2D | Ex-VIIGG2D | 30-64 | 55 | 20 | 59.61 | 82 |
| G 2-1/2 | Ex-VIIGG2-1/2 | 30-64 | 55 | 22 | 75.18 | 82 |
| G 3 | Ex-VIIGG3 | 36-80 | 70 | 22 | 87.88 | 98 |
| G 4 | Ex-VIIGG4 | 47-103 | 90 | 22 | 113.03 | 125 |
Ex-BG Clamping Gland for Unarmoured Cable
Brass cable entry
Ex-BG Clamping Gland for Unarmoured Cable
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M12 × 1.5 | Ex-BGM12-8 | 4-8 | 12 | 12 | 18/18 |
| M14 × 1.5 | Ex-BGM14-8 | 4-8 | 12 | 14 | 18/18 |
| M16 × 1.5 | Ex-BGM16-8 | 4-8 | 12 | 16 | 18/18 |
| M16 × 1.5 | Ex-BGM16-10 | 5-10 | 12 | 16 | 22/22 |
| M18 × 1.5 | Ex-BGM18-10 | 5-10 | 12 | 18 | 22/22 |
| M20 × 1.5 | Ex-BGM20-10 | 5-10 | 12 | 20 | 22/24 |
| M20 × 1.5 | Ex-BGM20-12 | 8-12 | 12 | 20 | 24/24 |
| M20 × 1.5 | Ex-BGM20-14 | 10-14 | 12 | 20 | 26/26 |
| M22 × 1.5 | Ex-BGM22-14 | 10-14 | 12 | 22 | 26/26 |
| M24 × 1.5 | Ex-BGM24-14 | 10-14 | 12 | 24 | 26/26 |
| M25 × 1.5 | Ex-BGM25-12 | 8-12 | 15 | 25 | 24/30 |
| M25 × 1.5 | Ex-BGM25-14 | 10-14 | 15 | 25 | 26/30 |
| M25 × 1.5 | Ex-BGM25-18 | 13-18 | 15 | 25 | 32/32 |
| M27 × 1.5 | Ex-BGM27-18 | 13-18 | 15 | 27 | 32/32 |
| M30 × 1.5 | Ex-BGM30-18 | 13-18 | 15 | 30 | 32/32 |
| M32 × 1.5 | Ex-BGM32-25 | 18-25 | 17 | 32 | 40/40 |
| M36 × 1.5 | Ex-BGM36-25 | 18-25 | 17 | 36 | 40/40 |
| M40 × 1.5 | Ex-BGM40-32 | 25-32 | 17 | 40 | 50/50 |
| M48 × 1.5 | Ex-BGM48-32 | 25-32 | 17 | 48 | 50/50 |
| M50 × 1.5 | Ex-BGM50-39 | 32-39 | 17 | 50 | 60/60 |
| M60 × 1.5 | Ex-BGM60-44 | 36-44 | 17 | 60 | 65/65 |
| M63 × 1.5 | Ex-BGM63-44 | 36-44 | 17 | 63 | 65/68 |
| M63 × 1.5 | Ex-BGM63-54 | 45-54 | 17 | 63 | 75/75 |
| M64 × 2.0 | Ex-BGM64-54 | 45-54 | 17 | 64 | 75/75 |
| M72 × 1.5 | Ex-BGM72-54 | 45-54 | 20 | 72 | 80/80 |
| M75 × 2.0 | Ex-BGM75-66 | 55-66 | 20 | 75 | 85/90 |
| M78 × 2.0 | Ex-BGM78-66 | 55-66 | 20 | 78 | 90/90 |
| M80 × 2.0 | Ex-BGM80-66 | 55-66 | 20 | 80 | 90/90 |
| M88 × 2.0 | Ex-BGM88-77 | 67-77 | 20 | — | 100/100 |
| M90 × 2.0 | Ex-BGM90-77 | 67-77 | 20 | 90 | 100/100 |
| M100 × 2.0 | Ex-BGM100-87 | 78-87 | 20 | 100 | 110/110 |
| M110 × 2.0 | Ex-BGM110-99 | 88-99 | 20 | 110 | 120/120 |
| M120 × 2.0 | Ex-BGM120-108 | 99-108 | 20 | 120 | 130/130 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| NPT 1/4 | Ex-BGNPT1/4-8 | 4-8 | 12 | 13.61 | 18/18 |
| NPT 3/8 | Ex-BGNPT3/8-10 | 6-10 | 12 | 17.05 | 22/22 |
| NPT 1/2-S | Ex-BGNPT1/2S-12 | 8-12 | 12 | 21.22 | 24/24 |
| NPT 1/2-D | Ex-BGNPT1/2D-14 | 10-14 | 12 | 21.22 | 26/26 |
| NPT 3/4 | Ex-BGNPT3/4-10 | 6-10 | 15 | 26.56 | 22/32 |
| NPT 3/4 | Ex-BGNPT3/4-14 | 10-14 | 15 | 26.56 | 26/32 |
| NPT 3/4 | Ex-BGNPT3/4-18 | 13-18 | 15 | 26.56 | 32/32 |
| NPT 1 | Ex-BGNPT1-25 | 18-25 | 17 | 33.28 | 40/40 |
| NPT 1-1/4 | Ex-BGNPT1-1/4-32 | 25-32 | 17 | 41.98 | 50/50 |
| NPT 1-1/2 | Ex-BGNPT1-1/2-32 | 25-32 | 17 | 48.05 | 50/52 |
| NPT 1-1/2 | Ex-BGNPT1-1/2-39 | 32-39 | 17 | 48.05 | 52/52 |
| NPT 2-S | Ex-BGNPT2S-44 | 37-44 | 17 | 60.09 | 65/65 |
| NPT 2-1/2 | Ex-BGNPT2-1/2-54 | 44-54 | 20 | 72.69 | 75/85 |
| NPT 2-1/2 | Ex-BGNPT2-1/2-66 | 54-66 | 20 | 72.69 | 85/85 |
| NPT 3-S | Ex-BGNPT3S-77 | 66-77 | 20 | 88.60 | 100/100 |
| NPT 4-S | Ex-BGNPT4S-99 | 88-99 | 20 | 113.97 | 122/122 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| G 1/4 | Ex-BGG1/4-8 | 4-8 | 12 | 13.15 | 18/18 |
| G 3/8 | Ex-BGG3/8-10 | 6-10 | 12 | 16.66 | 22/22 |
| G 1/2-S | Ex-BGG1/2S-12 | 8-12 | 12 | 20.95 | 24/24 |
| G 1/2-D | Ex-BGG1/2D-14 | 10-14 | 12 | 20.95 | 26/26 |
| G 3/4 | Ex-BGG3/4-10 | 6-10 | 15 | 26.44 | 22/32 |
| G 3/4 | Ex-BGG3/4-14 | 10-14 | 15 | 26.44 | 26/32 |
| G 3/4 | Ex-BGG3/4-18 | 13-18 | 15 | 26.44 | 32/32 |
| G 1 | Ex-BGG1-25 | 18-25 | 17 | 33.25 | 40/40 |
| G 1-1/4 | Ex-BGG1-1/4-32 | 25-32 | 17 | 41.91 | 50/50 |
| G 1-1/2 | Ex-BGG1-1/2-32 | 25-32 | 17 | 47.80 | 50/52 |
| G 1-1/2 | Ex-BGG1-1/2-39 | 32-39 | 17 | 47.80 | 52/52 |
| G 2 | Ex-BGG2-44 | 37-44 | 17 | 59.61 | 65/65 |
| G 2-1/2 | Ex-BGG2-1/2-54 | 44-54 | 20 | 75.18 | 75/85 |
| G 2-1/2 | Ex-BGG2-1/2-66 | 54-66 | 20 | 75.18 | 85/85 |
| G 3 | Ex-BGG3-77 | 66-77 | 20 | 87.88 | 100/100 |
| G 4 | Ex-BGG4-99 | 88-99 | 20 | 113.03 | 122/122 |
BDM-BDT / Ex-BDT Threaded Stopping Plug
Brass cable entry
BDM-BDT / Ex-BDT Threaded Stopping Plug
Model specificationsMetric thread
| Metric Thread | Model | Thread Length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Opposite side (mm) |
|---|---|---|---|---|---|
| M16×1.5 | Ex-BDTM16 | 15 | 16 | 19 | 20 |
| M20×1.5 | Ex-BDTM20 | 15 | 20 | 19 | 24 |
| M25×1.5 | Ex-BDTM25 | 15 | 25 | 20 | 30 |
| M32×1.5 | Ex-BDTM32 | 17 | 32 | 22 | 36 |
| M40×1.5 | Ex-BDTM40 | 17 | 40 | 23 | 45 |
| M50×1.5 | Ex-BDTM50 | 20 | 50 | 27 | 55 |
| M60×1.5 | Ex-BDTM60 | 20 | 60 | 27 | 64 |
| M63×1.5 | Ex-BDTM63 | 20 | 63 | 27 | 68 |
| M75×2.0 | Ex-BDTM75 | 22 | 75 | 30 | 80 |
| M88×2.0 | Ex-BDTM88 | 22 | 88 | 31 | 96 |
| M100×2.0 | Ex-BDTM100 | 22 | 100 | 32 | 110 |
| M115×2.0 | Ex-BDTM115 | 22 | 115 | 33 | 125 |
Model specificationsNPT thread
| American Thread | Model | Thread Length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Opposite side (mm) |
|---|---|---|---|---|---|
| NPT1/2 | Ex-BDTNPT1/2 | 15 | 21.22 | 19 | 24 |
| NPT3/4 | Ex-BDTNPT3/4 | 15 | 26.56 | 20 | 30 |
| NPT1 | Ex-BDTNPT1 | 17 | 33.28 | 22 | 36 |
| NPT1-1/4 | Ex-BDTNPT1-1/4 | 17 | 41.98 | 23 | 45 |
| NPT1-1/2 | Ex-BDTNPT1-1/2 | 20 | 48.05 | 27 | 55 |
| NPT2 | Ex-BDTNPT2 | 20 | 60.09 | 27 | 64 |
| NPT2-1/2 | Ex-BDTNPT2-1/2 | 22 | 72.69 | 30 | 80 |
| NPT3 | Ex-BDTNPT3 | 22 | 88.60 | 31 | 96 |
| NPT4 | Ex-BDTNPT4 | 22 | 113.97 | 33 | 125 |
Model specificationsG thread
| Inch Thread | Model | Thread Length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Opposite side (mm) |
|---|---|---|---|---|---|
| G1/2 | Ex-BDTG1/2 | 15 | 20.95 | 19 | 24 |
| G3/4 | Ex-BDTG3/4 | 15 | 26.44 | 20 | 30 |
| G1 | Ex-BDTG1 | 17 | 33.25 | 22 | 36 |
| G1-1/4 | Ex-BDTG1-1/4 | 17 | 41.91 | 23 | 45 |
| G1-1/2 | Ex-BDTG1-1/2 | 20 | 47.80 | 27 | 55 |
| G2 | Ex-BDTG2 | 20 | 59.61 | 27 | 64 |
| G2-1/2 | Ex-BDTG2-1/2 | 22 | 75.18 | 30 | 80 |
| G3 | Ex-BDTG3 | 22 | 87.88 | 31 | 96 |
| G4 | Ex-BDTG4 | 22 | 113.03 | 33 | 125 |
BGJ-A Female-to-Female Pipe Coupler
Brass cable entry
BGJ-A Female-to-Female Pipe Coupler
Model specificationsMetric thread
| Metric Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M16×1.5 | BGJAM16 | 15 | 16 | 34 | 22 |
| M20×1.5 | BGJAM20 | 15 | 20 | 34 | 27 |
| M25×1.5 | BGJAM25 | 15 | 25 | 34 | 32 |
| M32×1.5 | BGJAM32 | 17 | 32 | 39 | 38 |
| M40×1.5 | BGJAM40 | 17 | 40 | 39 | 47 |
| M50×1.5 | BGJAM50 | 20 | 50 | 46 | 57 |
| M63×1.5 | BGJAM63 | 20 | 63 | 46 | 68 |
| M75×2.0 | BGJAM75 | 20 | 75 | 47 | 84 |
| M90×2.0 | BGJAM90 | 20 | 90 | 47 | 98 |
| M115×2.0 | BGJAM115 | 20 | 115 | 48 | 125 |
Model specificationsNPT thread
| American Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| NPT3/8 | BGJANPT3/8 | 15 | 17.05 | 34 | 22 |
| NPT1/2 | BGJANPT1/2 | 15 | 21.22 | 34 | 27 |
| NPT3/4 | BGJANPT3/4 | 15 | 26.56 | 34 | 32 |
| NPT1 | BGJANPT1 | 17 | 33.28 | 39 | 38 |
| NPT1-1/4 | BGJANPT1-1/4 | 17 | 41.98 | 39 | 47 |
| NPT1-1/2 | BGJANPT1-1/2 | 20 | 48.05 | 46 | 57 |
| NPT2 | BGJANPT2 | 20 | 60.09 | 46 | 68 |
| NPT2-1/2 | BGJANPT2-1/2 | 20 | 72.69 | 47 | 84 |
| NPT3 | BGJANPT3 | 20 | 88.60 | 47 | 98 |
| NPT4 | BGJANPT4 | 20 | 113.97 | 48 | 125 |
Model specificationsG thread
| Inch Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| G3/8 | BGJAG3/8 | 15 | 16.66 | 34 | 22 |
| G1/2 | BGJAG1/2 | 15 | 20.95 | 34 | 27 |
| G3/4 | BGJAG3/4 | 15 | 26.44 | 34 | 32 |
| G1 | BGJAG1 | 17 | 33.25 | 39 | 38 |
| G1-1/4 | BGJAG1-1/4 | 17 | 41.91 | 39 | 47 |
| G1-1/2 | BGJAG1-1/2 | 20 | 47.80 | 46 | 57 |
| G2 | BGJAG2 | 20 | 59.61 | 46 | 68 |
| G2-1/2 | BGJAG2-1/2 | 20 | 75.18 | 47 | 84 |
| G3 | BGJAG3 | 20 | 87.88 | 47 | 98 |
| G4 | BGJAG4 | 20 | 113.03 | 48 | 125 |
BGJ-B Thread Adapter — Reducer and Enlarger
Brass cable entry
BGJ-B Thread Adapter — Reducer and Enlarger
Model specificationsMetric thread
| Metric Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M16×1.5 | BGJBM16 | 15 | 16 | 34 | 22 |
| M20×1.5 | BGJBM20 | 15 | 20 | 34 | 27 |
| M25×1.5 | BGJBM25 | 15 | 25 | 34 | 32 |
| M32×1.5 | BGJBM32 | 17 | 32 | 39 | 38 |
| M40×1.5 | BGJBM40 | 17 | 40 | 39 | 47 |
| M50×1.5 | BGJBM50 | 20 | 50 | 46 | 57 |
| M63×1.5 | BGJBM63 | 20 | 63 | 46 | 68 |
| M75×2.0 | BGJBM75 | 20 | 75 | 47 | 84 |
| M90×2.0 | BGJBM90 | 20 | 90 | 47 | 98 |
| M115×2.0 | BGJBM115 | 20 | 115 | 48 | 125 |
Model specificationsNPT thread
| American Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| NPT3/8 | BGJBNPT3/8 | 15 | 17.05 | 34 | 22 |
| NPT1/2 | BGJBNPT1/2 | 15 | 21.22 | 34 | 27 |
| NPT3/4 | BGJBNPT3/4 | 15 | 26.56 | 34 | 32 |
| NPT1 | BGJBNPT1 | 17 | 33.28 | 39 | 38 |
| NPT1-1/4 | BGJBNPT1-1/4 | 17 | 41.98 | 39 | 47 |
| NPT1-1/2 | BGJBNPT1-1/2 | 20 | 48.05 | 46 | 57 |
| NPT2 | BGJBNPT2 | 20 | 60.09 | 46 | 68 |
| NPT2-1/2 | BGJBNPT2-1/2 | 20 | 72.69 | 47 | 84 |
| NPT3 | BGJBNPT3 | 20 | 88.60 | 47 | 98 |
| NPT4 | BGJBNPT4 | 20 | 113.97 | 48 | 125 |
Model specificationsG thread
| Inch Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| G3/8 | BGJBG3/8 | 15 | 16.66 | 34 | 22 |
| G1/2 | BGJBG1/2 | 15 | 20.95 | 34 | 27 |
| G3/4 | BGJBG3/4 | 15 | 26.44 | 34 | 32 |
| G1 | BGJBG1 | 17 | 33.25 | 39 | 38 |
| G1-1/4 | BGJBG1-1/4 | 17 | 41.91 | 39 | 47 |
| G1-1/2 | BGJBG1-1/2 | 20 | 47.80 | 46 | 57 |
| G2 | BGJBG2 | 20 | 59.61 | 46 | 68 |
| G2-1/2 | BGJBG2-1/2 | 20 | 75.18 | 47 | 84 |
| G3 | BGJBG3 | 20 | 87.88 | 47 | 98 |
| G4 | BGJBG4 | 20 | 113.03 | 48 | 125 |
BGJ-C Male-to-Male Reducing Nipple
Brass cable entry
BGJ-C Male-to-Male Reducing Nipple
Model specificationsMetric thread
| Metric Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| M16×1.5 | BGJCM16 | 15 | 16 | 34 | 20 |
| M20×1.5 | BGJCM20 | 15 | 20 | 34 | 24 |
| M25×1.5 | BGJCM25 | 15 | 25 | 34 | 30 |
| M32×1.5 | BGJCM32 | 17 | 32 | 39 | 38 |
| M40×1.5 | BGJCM40 | 17 | 40 | 39 | 45 |
| M50×1.5 | BGJCM50 | 20 | 50 | 46 | 55 |
| M63×1.5 | BGJCM63 | 20 | 63 | 46 | 68 |
| M75×2.0 | BGJCM75 | 20 | 75 | 47 | 80 |
| M90×2.0 | BGJCM90 | 20 | 90 | 47 | 98 |
| M115×2.0 | BGJCM115 | 20 | 115 | 48 | 120 |
Model specificationsNPT thread
| American Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| NPT3/8 | BGJCNPT3/8 | 15 | 17.05 | 34 | 20 |
| NPT1/2 | BGJCNPT1/2 | 15 | 21.22 | 34 | 24 |
| NPT3/4 | BGJCNPT3/4 | 15 | 26.56 | 34 | 30 |
| NPT1 | BGJCNPT1 | 17 | 33.28 | 39 | 38 |
| NPT1-1/4 | BGJCNPT1-1/4 | 17 | 41.98 | 39 | 45 |
| NPT1-1/2 | BGJCNPT1-1/2 | 20 | 48.05 | 46 | 55 |
| NPT2 | BGJCNPT2 | 20 | 60.09 | 46 | 68 |
| NPT2-1/2 | BGJCNPT2-1/2 | 20 | 72.69 | 47 | 80 |
| NPT3 | BGJCNPT3 | 20 | 88.60 | 47 | 98 |
| NPT4 | BGJCNPT4 | 20 | 113.97 | 48 | 120 |
Model specificationsG thread
| Inch Thread | Model | Thread length GL (mm) | Thread outside diameter AG (mm) | Overall Length OL(mm) | Spanner size (mm) |
|---|---|---|---|---|---|
| G3/8 | BGJCG3/8 | 15 | 16.66 | 34 | 20 |
| G1/2 | BGJCG1/2 | 15 | 20.95 | 34 | 24 |
| G3/4 | BGJCG3/4 | 15 | 26.44 | 34 | 30 |
| G1 | BGJCG1 | 17 | 33.25 | 39 | 38 |
| G1-1/4 | BGJCG1-1/4 | 17 | 41.91 | 39 | 45 |
| G1-1/2 | BGJCG1-1/2 | 20 | 47.80 | 46 | 55 |
| G2 | BGJCG2 | 20 | 59.61 | 46 | 68 |
| G2-1/2 | BGJCG2-1/2 | 20 | 75.18 | 47 | 80 |
| G3 | BGJCG3 | 20 | 87.88 | 47 | 98 |
| G4 | BGJCG4 | 20 | 113.03 | 48 | 120 |
BGJ-D Male-to-Female Reducing Bushing
Brass cable entry
BGJ-D Male-to-Female Reducing Bushing
Model specificationsMetric thread
| Thread sizes | Model | Male thread | Internal thread | Thread outside diameter AG (mm) | Overall length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M20-M16 | BGJDM16 | M20x1.5 | M16x1.5 | 20-16 | 22 | 24 |
| M25-M20 | BGJDM20 | M25x1.5 | M20x1.5 | 25-20 | 25 | 24 |
| M32-M25 | BGJDM25 | M32x1.5 | M25x1.5 | 32-25 | 28 | 30 |
| M40-M32 | BGJDM32 | M40x1.5 | M32x1.5 | 40-32 | 30 | 38 |
| M50-M40 | BGJDM40 | M50x1.5 | M40x1.5 | 50-40 | 30 | 45 |
| M63-M50 | BGJDM50 | M63x1.5 | M50x1.5 | 63-50 | 32 | 55 |
| M75-M63 | BGJDM63 | M75x1.5 | M63x1.5 | 75-63 | 35 | 68 |
| M90-M75 | BGJDM75 | M90x2 | M75x1.5 | 90-75 | 36 | 80 |
| M115-M90 | BGJDM90 | M115x2 | M90x2 | 115-90 | 36 | 98 |
Model specificationsNPT thread
| Thread sizes | Model | Male thread | Internal thread | Thread outside diameter AG (mm) | Overall length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| NPT1/2-NPT3/8 | BGJDNPT3/8 | NPT1/2 | NPT3/8 | 21.22-17.05 | 22 | 24 |
| NPT3/4-NPT1/2 | BGJDNPT1/2 | NPT3/4 | NPT1/2 | 26.56-21.22 | 25 | 24 |
| NPT1-NPT3/4 | BGJDNPT3/4 | NPT1 | NPT3/4 | 33.28-26.56 | 28 | 30 |
| NPT1-1/4-NPT1 | BGJDNPT1 | NPT1-1/4 | NPT1 | 41.98-33.28 | 30 | 38 |
| NPT1-1/2-NPT1-1/4 | BGJDNPT1-1/4 | NPT1-1/2 | NPT1-1/4 | 48.05-41.98 | 30 | 45 |
| NPT2-NPT1-1/2 | BGJDNPT1-1/2 | NPT2 | NPT1-1/2 | 60.09-48.05 | 32 | 55 |
| NPT2-1/2-NPT2 | BGJDNPT2 | NPT2-1/2 | NPT2 | 72.69-60.09 | 35 | 68 |
| NPT3-NPT2-1/2 | BGJDNPT2-1/2 | NPT3 | NPT2-1/2 | 88.60-72.69 | 36 | 80 |
| NPT4-NPT3 | BGJDNPT3 | NPT4 | NPT3 | 113.97-88.60 | 36 | 98 |
Model specificationsG thread
| Thread sizes | Model | Male thread | Internal thread | Thread outside diameter AG (mm) | Overall length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| G1/2-G3/8 | BGJDG3/8 | G1/2 | G3/8 | 20.95-16.66 | 22 | 24 |
| G3/4-G1/2 | BGJDG1/2 | G3/4 | G1/2 | 26.44-20.95 | 25 | 24 |
| G1-G3/4 | BGJDG3/4 | G1 | G3/4 | 33.25-26.44 | 28 | 30 |
| G1-1/4-G1 | BGJDG1 | G1-1/4 | G1 | 41.91-33.25 | 30 | 38 |
| G1-1/2-G1-1/4 | BGJDG1-1/4 | G1-1/2 | G1-1/4 | 47.80-41.91 | 30 | 45 |
| G2-G1-1/2 | BGJDG1-1/2 | G2 | G1-1/2 | 59.61-47.80 | 32 | 55 |
| G2-1/2-G2 | BGJDG2 | G2-1/2 | G2 | 75.18-59.61 | 35 | 68 |
| G3-G2-1/2 | BGJDG2-1/2 | G3 | G2-1/2 | 87.88-75.18 | 36 | 80 |
| G4-G3 | BGJDG3 | G4 | G3 | 113.03-87.88 | 36 | 98 |
Nickel-Plated Brass Waterproof Breathable Cable Gland
Brass cable entry
Nickel-Plated Brass Waterproof Breathable Cable Gland
Model specificationsMetric breathable cable-entry dimensions
| Entry thread | Cable diameter (mm) | Airflow at 70 mbar (ml/min) | Thread diameter AG (mm) | Thread length GL (mm) | Spanner size (mm) | Protection rating |
|---|---|---|---|---|---|---|
| M10×1.5 | 3–7 | ≥100 | 10 | 6 | 14 | IP68 |
| M12×1.5 | 3–7 | ≥100 | 12 | 6 | 14 | IP68 |
| M12×1.5 | 4–8 | ≥100 | 12 | 7 | 17 | IP68 |
| M12×1.5 | 4–8 | ≥200 | 12 | 7.5 | 18 | IP68 |
| M16×1.5 | 4–8 | ≥200 | 16 | 7.5 | 18 | IP68 |
| M16×1.5 | 5–10 | ≥300 | 16 | 7.5 | 22 | IP68 |
| M18×1.5 | 5–10 | ≥300 | 18 | 8 | 22 | IP68 |
| M20×1.5 | 6–12 | ≥300 | 20 | 8 | 22 | IP68 |
| M22×1.5 | 10–14 | ≥500 | 22 | 8 | 27 | IP68 |
| M25×1.5 | 10–16 | ≥500 | 25 | 9 | 27 | IP68 |
Product comparison
Compare models
Compare the construction and application of each model.| Product | Construction | Use when | Check first | Review |
|---|---|---|---|---|
| Brass Cable Gland — Metric, PG, G and NPT | Standard Brass Cable Glands | A cable entry needs a nickel-plated brass body with an EPDM or silicone seal. |
| View specifications |
| 90-Degree Brass Fitting for Flexible Conduit | Right-Angle Brass Glands | A conduit run needs a right-angle connection close to the enclosure. |
| View specifications |
| Extended-Thread Metal Cable Gland for Thick Panels | Extended-Thread Brass Glands | A standard-length gland does not leave enough usable thread for the panel, washer and locknut. |
| View specifications |
| Brass Cable Gland with Silicone Seals | Standard Brass Cable Glands | A cable entry requires a silicone seal and O-ring. |
| View specifications |
| Multi-Hole Brass Cable Gland for 2–8 Cables | Multi-Hole Brass Glands | Two to eight small cables need to pass through one metal gland body. |
| View specifications |
| Brass Cable Gland with Flexible Bend Guard | Anti-Bending Brass Glands | A metal gland needs a flexible tail to guide the cable away from the entry. |
| View specifications |
| Double-Locked Brass Cable Gland | Double-Lock Brass Glands | The cable installation calls for a dual-clamping gland construction. |
| View specifications |
| BR-Series Breathable Brass Cable Gland | Special Brass Gland Series | An enclosure design calls for a venting gland at the cable entry. |
| View specifications |
| MG-Series Brass Cable Gland | Standard Brass Cable Glands | A straight metal cable entry calls for the MG construction. |
| View specifications |
| Straight-Through Brass Cable Gland — Standard and Long Thread | Standard Brass Cable Glands | A straight cable entry needs a choice of mounting-thread length for a thin or thick panel. |
| View specifications |
| 90-Degree Brass Conduit Fitting | Right-Angle Brass Glands | A flexible metallic or liquid-tight conduit must turn at the equipment entry. |
| View specifications |
| M-NW Female-Thread Cable Gland for Threaded Conduit | Special Brass Gland Series | A cable gland must join a male-threaded conduit or fitting through an internal-thread connection. |
| View specifications |
| M-NLW Internal-Thread Cable Gland | Special Brass Gland Series | The equipment or adjoining fitting presents a male thread that needs a female-thread cable gland. |
| View specifications |
| M-LBK Double-Flare Cable Gland | Special Brass Gland Series | The installation drawing calls for the double-flare M-LBK construction. |
| View specifications |
| MG-Series EMC Cable Gland | Brass EMC Cable Glands | A screened cable enters an enclosure and its screen needs a connection through an MG gland. |
| View specifications |
| Spring-Contact EMC Cable Gland | Brass EMC Cable Glands | A screened cable needs a spring-contact termination at the enclosure entry. |
| View specifications |
| D-Series EMC Cable Gland | Brass EMC Cable Glands | Connect a cable screen at the enclosure entry with an NBR seal around the cable jacket. |
| View specifications |
| F-Series EMC Cable Gland for Metric Entries | Brass EMC Cable Glands | A screened-cable installation calls for an F-series gland with a Metric enclosure thread. |
| View specifications |
| BW Cable Gland for Indoor SWA Cable | Brass Armoured Cable Glands | An SWA cable requires a BW armour-lock construction for an indoor, dry location. |
| View specifications |
| CW Single-Compression Cable Gland for SWA | Brass Armoured Cable Glands | An SWA cable installation requires a CW single-compression sealing construction. |
| View specifications |
| Ex-VII Double-Seal Armoured Cable Gland | Explosion-Protected Brass Glands | An armoured cable requires the Ex-VII double-seal construction. |
| View specifications |
| Ex-B Cable Gland for Unarmoured Cable | Explosion-Protected Brass Glands | An unarmoured cable entry calls for the Ex-B construction and a specified seal material. |
| View specifications |
| Ex-V Single-Seal Armoured Cable Gland | Explosion-Protected Brass Glands | An armoured-cable installation calls for the Ex-V single-seal arrangement. |
| View specifications |
| Ex-VI Clamping Gland for Unarmoured Cable | Explosion-Protected Brass Glands | An unarmoured cable needs an Ex-VI clamping gland at a threaded equipment entry. |
| View specifications |
| Ex-VIG Clamping Gland for Unarmoured Cable | Explosion-Protected Brass Glands | A clamping gland with a nickel-plated brass or stainless steel body. |
| View specifications |
| Ex-VIIIG Single-Seal Armoured Cable Gland | Explosion-Protected Brass Glands | An armoured cable requires the Ex-VIIIG single-seal construction. |
| View specifications |
| Ex-VIIG Double-Seal Armoured Cable Gland | Explosion-Protected Brass Glands | An armoured cable entry requires the Ex-VIIG double-seal arrangement. |
| View specifications |
| Ex-BG Clamping Gland for Unarmoured Cable | Explosion-Protected Brass Glands | An unarmoured cable entry needs NBR, PTFE or silicone seal options with a Metric, NPT or G connection. |
| View specifications |
| BDM-BDT / Ex-BDT Threaded Stopping Plug | Explosion-Protected Brass Glands | A threaded enclosure entry is unused and needs a solid closure. |
| View specifications |
| BGJ-A Female-to-Female Pipe Coupler | Explosion-Protected Brass Glands | Two male-threaded connections need a female-to-female coupler. |
| View specifications |
| BGJ-B Thread Adapter — Reducer and Enlarger | Explosion-Protected Brass Glands | The equipment entry and adjoining connection need different thread sizes. |
| View specifications |
| BGJ-C Male-to-Male Reducing Nipple | Explosion-Protected Brass Glands | Two female-threaded components need a male-to-male connecting nipple. |
| View specifications |
| BGJ-D Male-to-Female Reducing Bushing | Explosion-Protected Brass Glands | A larger female-threaded entry needs to accept a smaller male-threaded component. |
| View specifications |
| Nickel-Plated Brass Waterproof Breathable Cable Gland | Breathable Brass Cable Glands | Cable entry with nickel-plated brass body and enclosure ventilation. |
| View specifications |
Need a size that is not shown? Send us the cable diameter and entry thread.
Selection checks
Choose the right size and construction
Measure the cable diameter and identify the enclosure thread. These details determine which gland will fit.
- Cable and seal rangeChoose a sealing range that includes the measured cable outside diameter.
- Thread designationUse the complete thread system, size and pitch for the enclosure entry.
- Material and bonding dutyChoose the body finish and seal for the environment. If earthing is required, include the gland-to-enclosure connection.
Product support
Need help choosing a cable gland?
Send a model name, a photo or a short question. We can help with sizes, samples and a quotation. If you have them, the details below help us narrow down the options.
Request product support- CableOutside diameter and cable type, if known.
- Armour or screenA cable cross-section photo can help identify the construction.
- Equipment entryThread marking, hole size or an entry drawing.
- Body and sealTell us if your project specifies a material.
- InstallationDescribe where the gland will be used and any heat, water or chemical exposure.
- Project requirementsInclude any required standard or certificate reference.
- Model or photoStart with a model number, a photo or a short question.
Brass Cable Glands FAQ
Cable gland questions
Find answers about fit, assembly and product differences.
Brass Cable Glands
01When is a long-thread brass gland useful?
A longer entry thread can reach through a thick enclosure wall or gland plate and leave room for the locknut. Compare the usable thread length with the complete wall and washer stack.
02Does a metal gland automatically connect the cable screen?
No. Screen termination needs an EMC gland with a contact designed for the cable screen. A standard brass body alone does not provide that contact.
Brass Cable Gland — Metric, PG, G and NPT
Brass Cable Gland — Metric, PG, G and NPT
01Which seals are available for this brass gland?
The cable seal and O-ring are available in EPDM or silicone rubber.
02How are thread size and cable range matched?
Select the enclosure thread first, then choose a row whose sealing range includes the measured cable outside diameter. The same nominal thread can have more than one cable range.
03Are locknuts included with NPT versions?
NPT versions are supplied without a locknut as standard. A locknut can be requested separately.
90-Degree Brass Fitting for Flexible Conduit
90-Degree Brass Fitting for Flexible Conduit
01What does this right-angle fitting connect?
Its application is flexible metallic or liquid-tight conduit. Match the conduit connection as well as the threaded enclosure end.
02Which ingress rating applies to the complete elbow assembly?
The rating needs to apply to the assembled elbow, conduit and seals. An individual component rating cannot establish the rating of that complete assembly.
Extended-Thread Metal Cable Gland for Thick Panels
Extended-Thread Metal Cable Gland for Thick Panels
01How do I select the entry length?
Compare usable thread length with the panel thickness and the space occupied by the washer and locknut. Overall gland height is a different dimension.
02Is the stainless-steel version the same material as the brass version?
No. Nickel-plated brass and stainless steel are separate body options. Specify the required body material when requesting a model.
Brass Cable Gland with Silicone Seals
Brass Cable Gland with Silicone Seals
01Which sealing material does this gland use?
The seal and O-ring are silicone rubber.
02What information is needed for a high-temperature application?
State the working temperature, exposure duration and cable-jacket material. The continuous and short-term limits must apply to the complete gland assembly, not just the silicone material.
Multi-Hole Brass Cable Gland for 2–8 Cables
Multi-Hole Brass Cable Gland for 2–8 Cables
01Do all cables need to be the same diameter?
Each cable must fit its own bore. The correct insert is defined by the number and diameter of the holes, rather than only the gland thread size.
02Can I use a multi-hole gland for a loose bundle?
The insert seals individual cable jackets in separate bores. It does not seal a loose bundle as though it were one round cable.
Brass Cable Gland with Flexible Bend Guard
Brass Cable Gland with Flexible Bend Guard
01Does the flexible guard replace the cable bend-radius requirement?
No. It supports the cable locally, but the free cable still needs enough space for its specified minimum bend radius.
02What is the ingress protection rating of this spring-guard gland?
The spring-guard gland is rated IP68. Choose the seal for the cable diameter and fit the gland and enclosure washer correctly.
Double-Locked Brass Cable Gland
Double-Locked Brass Cable Gland
01Does “double-locked” specify a pull-out force?
No. It describes the construction. A required retention force needs a test result for the chosen model and cable.
02Which thread options are available?
The range includes Metric and PG threads. The cable sealing range and gland dimensions are selected separately from the thread designation.
BR-Series Breathable Brass Cable Gland
BR-Series Breathable Brass Cable Gland
01Will a venting gland prevent all condensation?
No. Condensation also depends on humidity, temperature changes and the enclosure. Vent performance must suit the enclosure’s pressure-equalization needs.
02What should I provide for a venting application?
Start with the enclosure size, cable diameter and operating environment. Required airflow and water exposure help identify the appropriate venting construction.
MG-Series Brass Cable Gland
MG-Series Brass Cable Gland
01Which seal materials are available for MG?
The MG seal and O-ring are available in EPDM or silicone rubber.
02What do the part letters refer to?
The construction drawing identifies the metal body parts as A, C and F, the sealing parts as B and D, and the PA66 claw as E.
Straight-Through Brass Cable Gland — Standard and Long Thread
Straight-Through Brass Cable Gland — Standard and Long Thread
01When is the long-thread version needed?
Use the longer entry when the panel, washer and locknut need more usable thread than the standard version provides.
02Can a standard and long-thread version share a cable size?
Thread length and sealing range are separate choices. Match the required entry length and cable outside diameter to the same model row.
90-Degree Brass Conduit Fitting
90-Degree Brass Conduit Fitting
01Can this fitting be sized from the cable inside the conduit?
No. The conduit type and outside profile determine the conduit connection. The cable inside does not identify the required fitting size.
02What space does the elbow need?
Allow for the elbow body, the conduit bend beyond it and tool access. Also allow room to turn the threaded body during installation.
M-NW Female-Thread Cable Gland for Threaded Conduit
M-NW Female-Thread Cable Gland for Threaded Conduit
01Which end connects to the threaded conduit?
The internal-thread connection receives the matching male-threaded conduit or fitting. The cable-side seal is selected from the cable outside diameter.
02Is M-NW interchangeable with M-NLW?
They are separate model series. Use the specified connection form and installation dimensions for the requested series rather than substituting one from its name alone.
M-NLW Internal-Thread Cable Gland
M-NLW Internal-Thread Cable Gland
01How does a female-thread gland differ from an ordinary male-thread gland?
Its internal-thread connection joins a matching male thread. An ordinary male-thread gland connects to a female-threaded opening or passes through a panel with a locknut.
02Which dimensions matter at the mating entry?
Thread standard, nominal size and usable engagement must match the male end. Cable diameter remains a separate measurement at the sealing end.
M-LBK Double-Flare Cable Gland
M-LBK Double-Flare Cable Gland
01Does the double-flare shape establish a vibration rating?
No. The shape identifies the construction; vibration and cable-retention performance need evidence for the selected model and cable.
02How do I identify the correct M-LBK size?
Use the M-LBK model code with the cable outside diameter and the entry dimensions. The complete thread designation is needed when placing an order.
MG-Series EMC Cable Gland
MG-Series EMC Cable Gland
01What distinguishes MG EMC from the ordinary MG gland?
The EMC construction adds contact to the cable screen. The ordinary MG gland provides the cable-entry and sealing construction without that screen-contact function.
02Is cable outside diameter enough to choose an EMC gland?
No. The screen construction and contact diameter also matter. Cable-jacket diameter identifies the sealing range, while the exposed screen must fit the contact arrangement.
Spring-Contact EMC Cable Gland
Spring-Contact EMC Cable Gland
01How is the screen contacted in this gland?
A spring contacts the exposed cable screen inside the gland. The screen preparation and contact diameter must suit that spring.
02Does the screen contact replace cable sealing?
No. The spring makes the electrical contact; the NBR sealing parts act around the cable. Both interfaces must fit the selected cable.
D-Series EMC Cable Gland
D-Series EMC Cable Gland
01Can a D-series gland replace a spring-contact EMC gland?
Not from the EMC label alone. The screen-contact construction, cable preparation and mounting dimensions must match the installation.
02What cable information identifies a D-series size?
Provide the jacket outside diameter and the screen construction and diameter. These describe the separate sealing and screen-contact interfaces.
F-Series EMC Cable Gland for Metric Entries
F-Series EMC Cable Gland for Metric Entries
01What thread system does the F series use?
The F-series gland uses Metric threads. PG, G and NPT versions belong to other constructions in the EMC range.
02Does choosing an EMC gland guarantee the equipment’s shielding performance?
No. The cable screen, contact arrangement and enclosure bonding form one system. The gland provides the screen-contact component within that system.
03Which F-series dimensions are available for selection?
The table gives the entry thread, cable range and wrench dimensions. Request the current drawing for thread length and overall height before machining the enclosure.
BW Cable Gland for Indoor SWA Cable
BW Cable Gland for Indoor SWA Cable
01How does BW differ from CW?
BW is the indoor, dry-location two-part armour-lock form with an IP30 specification. CW is a single-compression construction with IP66/IP67 specifications. Their sealing arrangements are different.
02Which cable dimensions identify a BW size?
The armour construction and diameter must fit the armour lock. The cable bedding, overall dimensions and enclosure thread identify the rest of the assembly.
CW Single-Compression Cable Gland for SWA
CW Single-Compression Cable Gland for SWA
01Why choose CW instead of BW?
BW is intended for indoor, dry locations with an IP30 specification. CW uses a single-compression construction with IP66/IP67 specifications. Choose the construction that matches the cable sealing and installation conditions.
02Does the CW name establish hazardous-area approval?
No. Hazardous-area use requires a current certificate covering the exact gland, cable construction and installation. A CW designation or an IP rating is not that approval.
Ex-VII Double-Seal Armoured Cable Gland
Ex-VII Double-Seal Armoured Cable Gland
01Which armoured cable types does Ex-VII cover?
The construction is intended for steel-wire, braided and steel-tape armoured cables. Each cable’s dimensions must fit the sealing and armour-clamping ranges of the chosen size.
02How does Ex-VII differ from a single-seal gland?
Ex-VII uses a double-seal construction. It should be selected using the dimensions of both sealing interfaces as well as the armour-clamping arrangement.
03What is needed for hazardous-area use?
The exact Ex-VII configuration needs a current certificate matching the equipment protection concept, cable and installation. The model name does not establish that scope.
04How do I select an Ex-VII size?
Compare the cable range, maximum outlet diameter and entry thread. For example, Ex-VIIM20D has a 9–20 mm cable range and a 16 mm maximum outlet.
Ex-B Cable Gland for Unarmoured Cable
Ex-B Cable Gland for Unarmoured Cable
01Is Ex-B an armour-clamping gland?
No. Ex-B is the unarmoured-cable construction. An armoured cable needs a gland with the appropriate armour-retention arrangement.
02Can the seal materials be substituted freely?
No. Seal material is part of the selected configuration. Temperature, chemical exposure and any applicable certificate must cover that combination.
03Which approval should accompany an Ex-B order?
Request the current certificate for the exact BDM Ex-B configuration. Its protection marking and permitted installation conditions must match the equipment and location.
Ex-V Single-Seal Armoured Cable Gland
Ex-V Single-Seal Armoured Cable Gland
01How does Ex-V differ from Ex-VII?
Ex-V is the single-seal construction; Ex-VII is a double-seal construction. Their sealing arrangements and dimensional requirements are different.
02Is the Ex-V rating the same for every material option?
A rating cannot be assigned from the model name alone. The body, seal, cable and protection configuration must be identified together before an ingress, temperature or hazardous-area rating is specified.
Ex-VI Clamping Gland for Unarmoured Cable
Ex-VI Clamping Gland for Unarmoured Cable
01Does Ex-VI require armour or braid on the cable?
No. This construction is for unarmoured cable. A separate armour-clamping gland is needed when the cable armour must be retained at the entry.
02What distinguishes a complete Ex-VI specification?
It includes the cable diameter, entry thread, body and seal materials. Hazardous-area service also requires the certificate and marking for that exact combination.
Ex-VIG Clamping Gland for Unarmoured Cable
Ex-VIG Clamping Gland for Unarmoured Cable
01Can Ex-VIG be substituted for Ex-VI?
The similar names do not establish interchangeability. The cable range, mounting dimensions, sealing configuration and applicable certificate must match the installation.
02How should the stainless-steel option be specified?
Include the required 304 or 316 body grade with the Ex-VIG model and seal material. The grade applies to the selected body option, not automatically to every component.
Ex-VIIIG Single-Seal Armoured Cable Gland
Ex-VIIIG Single-Seal Armoured Cable Gland
01What is the difference between Ex-VIIIG and Ex-VIIG?
Ex-VIIIG is the single-seal version. Ex-VIIG uses double sealing. The required cable layers and sealing dimensions must be matched to the chosen construction.
02Can it be chosen only from the armour type?
No. Wire, braid or tape armour identifies the construction family, but the armour diameter and cable sealing dimensions identify the size.
03Does the model name establish the permitted zone?
No. Zone and protection requirements must be matched to the current certificate for the exact model and configuration.
04How do I select an Ex-VIIIG size?
Compare the cable range, maximum outlet diameter and entry thread. For example, Ex-VIIIGM20D has a 9–20 mm cable range and a 16 mm maximum outlet.
Ex-VIIG Double-Seal Armoured Cable Gland
Ex-VIIG Double-Seal Armoured Cable Gland
01Why does double sealing need more cable measurements?
Each sealing interface must fit the cable layer it contacts. Armour-clamping dimensions remain a separate part of the size selection.
02Is Ex-VIIG the same as Ex-VIIIG?
No. Ex-VIIG is the double-seal model, while Ex-VIIIG is the single-seal model. Keep the complete model designation with the dimensional and certificate requirements.
03How do I select an Ex-VIIG size?
Compare the cable range, maximum outlet diameter and entry thread. For example, Ex-VIIGM20D has a 9–20 mm cable range and a 16 mm maximum outlet.
Ex-BG Clamping Gland for Unarmoured Cable
Ex-BG Clamping Gland for Unarmoured Cable
01Is Ex-BG an alternative name for Ex-B?
They are separate model designations. A replacement needs the correct cable range, mounting dimensions and sealing arrangement, together with the applicable certificate.
02What should an Ex-BG enquiry identify?
Include the entry thread and cable outside diameter, then name the body and seal material required. For a hazardous location, include the equipment protection marking so the certificate scope can be matched.
BDM-BDT / Ex-BDT Threaded Stopping Plug
BDM-BDT / Ex-BDT Threaded Stopping Plug
01How is a stopping plug sized?
Match the complete entry thread and available engagement. Cable diameter is not a sizing dimension for a solid stopping plug.
02Can a general-purpose plug replace Ex-BDT?
For hazardous-area equipment, the replacement plug needs the appropriate certificate and installation conditions for that equipment. A matching thread alone is not sufficient.
BGJ-A Female-to-Female Pipe Coupler
BGJ-A Female-to-Female Pipe Coupler
01Does BGJ-A clamp or seal a cable jacket?
No. It is a threaded pipe coupler. Its two mating thread designations and engagement dimensions identify the connection.
02What information is needed for a reducing coupler?
Give the thread standard and size at each end, along with the required overall length. For hazardous-area equipment, the chosen coupler also needs the matching approval scope.
BGJ-B Thread Adapter — Reducer and Enlarger
BGJ-B Thread Adapter — Reducer and Enlarger
01What identifies a BGJ-B adapter?
Specify both mating thread designations and the required connection direction. One nominal size does not fully describe a reducer or enlarger.
02Can an adapter preserve hazardous-area approval automatically?
No. An adapter used on hazardous-area equipment must be permitted by the equipment and adapter certificates and their installation conditions.
BGJ-C Male-to-Male Reducing Nipple
BGJ-C Male-to-Male Reducing Nipple
01How does BGJ-C differ from BGJ-A?
BGJ-C has male threads at both ends. BGJ-A has female threads at both ends; they connect to opposite mating-thread forms.
02What dimensions are needed to order a reducing nipple?
State the full thread designation at each end, required engagement and overall length. Hazardous-area installations also need the certificate for the selected configuration.
BGJ-D Male-to-Female Reducing Bushing
BGJ-D Male-to-Female Reducing Bushing
01Which thread size goes first when describing a bushing?
Identify the outer male thread and inner female thread explicitly. For example, the Metric table includes an M20×1.5 male to M16×1.5 female reduction.
02Is a reducing bushing the same as a pipe coupler?
No. A bushing nests a smaller female connection inside a larger male thread. A coupler joins connections through two ends. Any hazardous-area use needs approval for the selected fitting.
Nickel-Plated Brass Waterproof Breathable Cable Gland
Nickel-Plated Brass Waterproof Breathable Cable Gland
01How do I choose the M12×1.5 version?
The two 4–8 mm cable versions have different airflow, thread length and spanner size. Compare the complete row before ordering.
02What pressure is used for the airflow figures?
Airflow is specified at a pressure difference of 70 mbar.