06 / Armour retention
Armoured Cable Glands
Armoured cable glands clamp the armour and retain the cable where it enters an enclosure. Choose the clamping arrangement for the armour type, then match the bedding, outer sheath and entry dimensions. Bonding accessories depend on the installation.
- Armour type and diameter
- Bedding and outer-sheath diameters
- Entry, bonding and accessory needs
Cable gland families
Compare cable glands by material, cable construction and duty.
Choose nylon, brass or stainless steel by body material, or compare EMC, armoured, hazardous-area, marine and conduit-entry designs by the job they must perform.
Armoured Cable Glands range
Choose your armoured cable glands
Glands that grip cable armour and seal the cable at the equipment entry.
Models & dimensions
Armoured Cable Glands: specifications and dimensions
Select a product to see its specifications, drawings and sizes.
Armoured Cable Glands
Which fitting do you need?
Choose a product above, or show all products to compare sizes and construction.- 01Cable and seal range
- 02Entry thread and dimensions
- 03Material and installation duty
BW Cable Gland for Indoor SWA Cable
01 / Armour retention
BW Cable Gland for Indoor SWA Cable
A BW two-part brass gland that locks steel-wire armour at an indoor, dry cable entry.
Product reference
- Construction
- BW Indoor Armoured Glands
- Application
- An SWA cable requires a BW armour-lock construction for an indoor, dry location.
Key specifications
- Gland Type
- BW 2-Part Armour Lock
- Application
- Indoor & Dry locations, for SWA (Steel Wire Armour) Cable
- Material
- Brass (Optional Nickel Plating)
- Protection Rating
- IP30
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Thread Options
- Metric, NPT, BSP, PG
- Accessories
- Locknut, Earth Tag, PVC Shroud
Key features
- Two-part armour lockThe BW construction mechanically retains the steel-wire armour.
- Indoor, dry applicationThe BW form is intended for indoor and dry locations.
- Accessory optionsLocknuts, earth tags and PVC shrouds are available for the installation.
CW Single-Compression Cable Gland for SWA
02 / Armour retention
CW Single-Compression Cable Gland for SWA
A CW single-compression brass cable gland for steel-wire-armoured cable, with sealing and armour retention at the entry.
Product reference
- Construction
- CW Armoured Cable Glands
- Application
- An SWA cable installation requires a CW single-compression sealing construction.
Key specifications
- Gland Type
- CW Single Compression
- Application
- Steel-wire-armoured cable entries
- Material
- Brass (Optional Nickel Plating)
- Protection Rating
- IP66 / IP67
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Operating Temperature
- -20°C to +80°C
- Thread Options
- Metric, NPT, BSP, PG
- Accessories
- Locknut, Earth Tag, PVC Shroud
Key features
- Single-compression formThe CW construction combines an armour-retention arrangement with a cable seal.
- Brass bodyThe body is brass, with nickel plating available as an option.
- Installation accessoriesThe range includes locknuts, earth tags and PVC shrouds.
Ex-VII Double-Seal Armoured Cable Gland
03 / Armour retention
Ex-VII Double-Seal Armoured Cable Gland
An Ex-VII metal cable gland with double sealing and an armour-clamping arrangement for wire-, braid- or tape-armoured cable.
Product reference
- Construction
- Ex-VII Double-Seal Armoured Glands
- Application
- An armoured cable requires the Ex-VII double-seal construction.
Key specifications
- Product Type
- Double-seal armoured cable gland
- Model
- Ex-VII d/e BDM
- Body Material
- Nickel-plated brass, SS304 stainless steel, or SS316 stainless steel
- Seal Material
- Silicone Rubber
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
- Applicable Cable
- Steel Wire, Braided, and Steel Tape Armoured Cables
Key features
- Double sealingThe Ex-VII construction incorporates two sealing stages with armour clamping.
- Silicone sealsThe gland uses silicone sealing parts within a nickel-plated brass body.
- Armoured-cable formsThe construction covers steel-wire, braided and steel-tape armour arrangements.
Ex-V Single-Seal Armoured Cable Gland
04 / Armour retention
Ex-V Single-Seal Armoured Cable Gland
An Ex-V single-seal metal gland with armour clamping for steel-wire and braided armoured cable constructions.
Product reference
- Construction
- Ex-V Single-Seal Armoured Glands
- Application
- An armoured-cable installation calls for the Ex-V single-seal arrangement.
Key specifications
- Product Type
- Single-seal armoured cable gland
- Model
- Ex-V
- Body Material
- Brass or stainless steel
- Seal Material
- Silicone or NBR
Product specifications
Construction and details

Assembly arrangement and dimensions
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Model specification tablesFurther specifications
- Applicable Cable
- Steel Wire Armour (SWA), Braided Armour, Jacketed Armour
Key features
- Single-seal constructionEx-V combines a single sealing arrangement with armour retention.
- Body and seal optionsThe range includes brass or stainless-steel bodies with silicone or NBR sealing options.
Ex-VIIG Double-Seal Armoured Cable Gland
05 / Armour retention
Ex-VIIG Double-Seal Armoured Cable Gland
An Ex-VIIG metal cable gland with double sealing and an armour-clamping system.
Product reference
- Construction
- Ex-VIIG Double-Seal Armoured Glands
- Application
- An armoured cable entry requires the Ex-VIIG double-seal arrangement.
Key specifications
- Product Type
- Double-seal armoured cable gland
- Model
- Ex-VIIG / BDM-VIIG
- Body Material
- Nickel-Plated Brass / Stainless Steel (304, 316)
- Seal Material
- Silicone Rubber
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
- Applicable Cable
- Steel Wire, Braided, and Steel Tape Armoured Cables
Key features
- Double-seal arrangementTwo sealing stages accompany the armour-clamping system.
- Silicone sealing partsThe gland uses silicone seals.
- Brass and stainless optionsThe range includes nickel-plated brass and 304 or 316 stainless-steel bodies.
Ex-VIIIG Single-Seal Armoured Cable Gland
06 / Armour retention
Ex-VIIIG Single-Seal Armoured Cable Gland
An Ex-VIIIG gland combining single sealing and armour clamping for wire-, braid- or tape-armoured cable.
Product reference
- Construction
- Ex-VIIIG Single-Seal Armoured Glands
- Application
- An armoured cable requires the Ex-VIIIG single-seal construction.
Key specifications
- Product Type
- Single-seal armoured cable gland
- Model
- Ex-VIIIG / BDM-VIIIG
- Body Material
- Nickel-Plated Brass / Stainless Steel (304, 316)
- Seal Material
- Silicone Rubber
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
This illustration does not establish the current model’s certification or approval.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: AG · GL
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -60°C to +100°C
- Applicable Cable
- Steel Wire, Braided, and Steel Tape Armoured Cables
Key features
- Single sealing with armour clampingThe Ex-VIIIG form combines one sealing arrangement with mechanical armour retention.
- Silicone sealsThe sealing components use silicone rubber.
- Metal body choicesNickel-plated brass and 304 or 316 stainless-steel versions are available.
Model specification tables
Model sizes
BW Cable Gland for Indoor SWA Cable
Armour retention
BW Cable Gland for Indoor SWA Cable
Model specificationsBW Cable Gland for Indoor SWA Cable — thread and cable dimensions
| Item Code | Thread Size (Metric) | Thread Size (NPT) | Min. Thread Length D (mm) | Unarmored Cable OD “A” (MIN–MAX, mm) | Armored Cable OD “B” (MIN–MAX, mm) |
|---|---|---|---|---|---|
| BW20S | M20 | 1/2″ | 10 | 11.50 | 15.50 |
| BW20L | M20 | 1/2″ | 10 | 14.00 | 20.50 |
| BW25S | M25 | 3/4″ | 10 | 18.00 | 24.00 |
| BW25L | M25 | 3/4″ | 10 | 20.00 | 27.00 |
| BW32S | M32 | 1″ | 10 | 26.30 | 33.50 |
| BW32L | M32 | 1″ | 10 | 26.30 | 33.50 |
| BW40S | M40 | 1-1/4″ | 13 | 31.50 | 39.50 |
| BW40L | M40 | 1-1/4″ | 13 | 32.00 | 40.00 |
| BW50S | M50 | 1-1/2″ | 13 | 38.20 | 46.30 |
| BW50L | M50 | 2″ | 13 | 44.00 | 52.60 |
| BW63S | M63 | 2″ | 14 | 50.10 | 59.00 |
| BW63L | M63 | 2-1/2″ | 14 | 56.00 | 65.30 |
| BW75S | M75 | 2-1/2″ | 15 | 62.00 | 71.60 |
| BW75L | M75 | 3″ | 15 | 68.00 | 78.00 |
| BW90 | M90 | 3″ | 20 | 80.50 | 91.00 |
CW Single-Compression Cable Gland for SWA
Armour retention
CW Single-Compression Cable Gland for SWA
Model specificationsCW Single-Compression Cable Gland for SWA — thread and cable dimensions
| Size Code | Thread outside diameter (mm) | Thread Length (mm) | Unarmored Cable OD “A” (MIN–MAX, mm) | Armored Cable OD “B” (MIN–MAX, mm) | Clamping Range (mm) | Wrench Size (mm) | Max Product OD (mm) |
|---|---|---|---|---|---|---|---|
| CW-20S | 20 | 10 | 6.0 – 10.0 | 8.0 – 15.8 | 0.9 / 1.25 | 24 | 27 |
| CW-20M | 20 | 10 | 8.0 – 11.8 | 12.9 – 17.2 | 0.9 / 1.25 | 27 | 30 |
| CW-20L | 20 | 10 | 11.0 – 14.0 | 15.5 – 20.8 | 0.9 / 1.25 | 30 | 33 |
| CW-25S | 25 | 10 | 12.0 – 17.0 | 17.5 – 24.0 | 1.25 / 1.60 | 34 | 36 |
| CW-25L | 25 | 10 | 13.0 – 20.3 | 24.0 – 26.5 | 1.25 / 1.60 | 36 | 39 |
| CW-32S | 32 | 12 | 17.0 – 24.0 | 25.0 – 32.0 | 1.60 / 2.00 | 44 | 46 |
| CW-32L | 32 | 12 | 19.0 – 26.2 | 26.7 – 34.0 | 1.60 / 2.00 | 46 | 48.5 |
| CW-40S | 40 | 14 | 23.0 – 27.0 | 31.0 – 37.0 | 1.60 / 2.00 | 52 | 57 |
| CW-40L | 40 | 14 | 25.0 – 32.2 | 33.0 – 40.5 | 1.60 / 2.00 | 55 | 58.5 |
| CW-50S | 50 | 15 | 31.5 – 37.0 | 39.4 – 45.0 | 2.00 / 2.50 | 58 | 65 |
| CW-50L | 50 | 15 | 36.5 – 42.0 | 45.7 – 50.0 | 2.00 / 2.50 | 65 | 72 |
| CW-63S | 63 | 15 | 42.5 – 47.0 | 52.1 – 56.0 | 2.5 | 68 | 75 |
| CW-63L | 63 | 15 | 49.1 – 56.0 | 58.4 – 66.0 | 2.5 | 80 | 89 |
| CW-75S | 75 | 15 | 54.5 – 58.0 | 64.8 – 68.0 | 2.5 | 82 | 90 |
| CW-75L | 75 | 15 | 57.5 – 64.0 | 68.0 – 74.0 | 2.5 | 92 | 103 |
| CW-90S | 90 | 15 | 66.0 – 76.0 | 77.0 – 86.0 | 2.50 / 3.15 | 106 | 118 |
| CW-90L | 90 | 15 | 66.0 – 79.0 | 77.0 – 90.0 | 2.50 / 3.15 | 106 | 118 |
| CW-100 | 100 | 17 | 80.0 – 90.9 | 92.0 – 101.5 | 3.15 / 4.00 | 123 | 135.3 |
| CW-115 | 115 | 17 | 87.0 – 97.9 | 101.0 – 110.3 | 3.15 / 4.00 | 133.4 | 146.7 |
Ex-VII Double-Seal Armoured Cable Gland
Armour retention
Ex-VII Double-Seal Armoured Cable Gland
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M16 × 1.5 | Ex-VIIM16 | 5-16 | 12 | 15 | 16 | 24 |
| M20 × 1.5 | Ex-VIIM20 | 5-16 | 12 | 15 | 20 | 24 |
| M20 × 1.5D | Ex-VIIM20D | 9-20 | 16 | 15 | 20 | 30 |
| M25 × 1.5 | Ex-VIIM25 | 9-20 | 16 | 15 | 25 | 30 |
| M25 × 1.5D | Ex-VIIM25D | 14-26 | 20 | 15 | 25 | 38 |
| M32 × 1.5 | Ex-VIIM32 | 14-26 | 20 | 17 | 32 | 38 |
| M32 × 1.5D | Ex-VIIM32D | 18-33 | 28 | 17 | 32 | 45 |
| M40 × 1.5 | Ex-VIIM40-33 | 18-33 | 28 | 17 | 40 | 45 |
| M40 × 1.5D | Ex-VIIM40D | 20-40 | 35 | 17 | 40 | 55 |
| M50 × 1.5 | Ex-VIIM50 | 20-40 | 35 | 20 | 50 | 55 |
| M50 × 1.5D | Ex-VIIM50D | 26-50 | 45 | 20 | 50 | 68 |
| M63 × 1.5 | Ex-VIIM63 | 26-50 | 45 | 20 | 63 | 68 |
| M63 × 1.5D | Ex-VIIM63D | 30-64 | 55 | 20 | 63 | 82 |
| M75 × 2 | Ex-VIIM75 | 30-64 | 55 | 22 | 75 | 82 |
| M88 × 2 | Ex-VIIM88 | 36-80 | 70 | 22 | 88 | 98 |
| M100 × 2 | Ex-VIIM100 | 41-90 | 80 | 22 | 100 | 110 |
| M115 × 2 | Ex-VIIM115 | 47-103 | 90 | 22 | 115 | 125 |
| M130 × 2 | Ex-VIIM130 | 63-119 | 100 | 22 | 130 | 140 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| NPT 3/8 | Ex-VIINPT3/8 | 5-16 | 12 | 15 | 17.05 | 24 |
| NPT 1/2 | Ex-VIINPT1/2 | 5-16 | 12 | 15 | 21.22 | 24 |
| NPT 1/2D | Ex-VIINPT1/2D | 9-20 | 16 | 15 | 21.22 | 30 |
| NPT 3/4 | Ex-VIINPT3/4 | 9-20 | 16 | 15 | 26.56 | 30 |
| NPT 3/4D | Ex-VIINPT3/4D | 14-26 | 20 | 15 | 26.56 | 38 |
| NPT 1 | Ex-VIINPT1 | 14-26 | 20 | 17 | 33.28 | 38 |
| NPT 1D | Ex-VIINPT1D | 18-33 | 28 | 17 | 33.28 | 45 |
| NPT 1-1/4 | Ex-VIINPT1-1/4 | 18-33 | 28 | 17 | 41.98 | 45 |
| NPT 1-1/4D | Ex-VIINPT1-1/4D | 20-40 | 35 | 17 | 41.98 | 55 |
| NPT 1-1/2 | Ex-VIINPT1-1/2 | 20-40 | 35 | 20 | 48.05 | 55 |
| NPT 1-1/2D | Ex-VIINPT1-1/2D | 26-50 | 45 | 20 | 48.05 | 68 |
| NPT 2 | Ex-VIINPT2 | 26-50 | 45 | 20 | 60.09 | 68 |
| NPT 2D | Ex-VIINPT2D | 30-64 | 55 | 20 | 60.09 | 82 |
| NPT 2-1/2 | Ex-VIINPT2-1/2 | 30-64 | 55 | 22 | 72.69 | 82 |
| NPT 3 | Ex-VIINPT3 | 36-80 | 70 | 22 | 88.60 | 98 |
| NPT 4 | Ex-VIINPT4 | 47-103 | 90 | 22 | 113.97 | 125 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| G 3/8 | Ex-VIIG3/8 | 5-16 | 12 | 15 | 16.66 | 24 |
| G 1/2 | Ex-VIIG1/2 | 5-16 | 12 | 15 | 20.95 | 24 |
| G 1/2D | Ex-VIIG1/2D | 9-20 | 16 | 15 | 20.95 | 30 |
| G 3/4 | Ex-VIIG3/4 | 9-20 | 16 | 15 | 26.44 | 30 |
| G 3/4D | Ex-VIIG3/4D | 14-26 | 20 | 15 | 26.44 | 38 |
| G 1 | Ex-VIIG1 | 14-26 | 20 | 17 | 33.25 | 38 |
| G 1D | Ex-VIIG1D | 18-33 | 28 | 17 | 33.25 | 45 |
| G 1-1/4 | Ex-VIIG1-1/4 | 18-33 | 28 | 17 | 41.91 | 45 |
| G 1-1/4D | Ex-VIIG1-1/4D | 20-40 | 35 | 17 | 41.91 | 55 |
| G 1-1/2 | Ex-VIIG1-1/2 | 20-40 | 35 | 20 | 47.80 | 55 |
| G 1-1/2D | Ex-VIIG1-1/2D | 26-50 | 45 | 20 | 47.80 | 68 |
| G 2 | Ex-VIIG2 | 26-50 | 45 | 20 | 59.61 | 68 |
| G 2D | Ex-VIIG2D | 30-64 | 55 | 20 | 59.61 | 82 |
| G 2-1/2 | Ex-VIIG2-1/2 | 30-64 | 55 | 22 | 75.18 | 82 |
| G 3 | Ex-VIIG3 | 36-80 | 70 | 22 | 87.88 | 98 |
| G 4 | Ex-VIIG4 | 47-103 | 90 | 22 | 113.03 | 125 |
Ex-V Single-Seal Armoured Cable Gland
Armour retention
Ex-V Single-Seal Armoured Cable Gland
Model specificationsEx-V — thread and cable dimensions
| Metric thread | Metric model | G/NPT thread size | NPT model | G model | Cable range B (mm) | Cable range A (mm) | H (mm) | L (mm) | Across flats (mm) | Across corners (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
| M16*1.5 | Ex-V08-M16 | 3/8″ | Ex-V08-NPT3/8 | Ex-V08-G3/8 | 5-8 | 3-6 | 30 | 12 | 24 | 28 |
| M16*1.5 | Ex-V10-M16 | 3/8″ | Ex-V10-NPT3/8 | Ex-V10-G3/8 | 6-10 | 4-8 | 30 | 12 | 24 | 28 |
| M20*1.5 | Ex-V14-M20 | 1/2″ | Ex-V14-NPT1/2 | Ex-V14-G1/2 | 9-14 | 6-11 | 30 | 12 | 24 | 28 |
| M20*1.5 | Ex-V16-M20 | 1/2″ | Ex-V16-NPT1/2 | Ex-V16-G1/2 | 10-16 | 7-12 | 30 | 12 | 24 | 28 |
| M20*1.5 | Ex-V18-M20 | 1/2″ | Ex-V18-NPT1/2 | Ex-V18-G1/2 | 13-18 | 9-14 | 32 | 12 | 30 | 35 |
| M25*1.5 | Ex-V21-M25 | 3/4″ | Ex-V21-NPT3/4 | Ex-V21-G3/4 | 15-21 | 11-17 | 35 | 13 | 36 | 42 |
| M25*1.5 | Ex-V24-M25 | 3/4″ | Ex-V24-NPT3/4 | Ex-V24-G3/4 | 17-24 | 13-20 | 35 | 13 | 40 | 47 |
| M32*1.5 | Ex-V28-M32 | 1″ | Ex-V28-NPT1 | Ex-V28-G1 | 20-28 | 16-23 | 39 | 15 | 46 | 53 |
| M32*1.5 | Ex-VK2-M32 | 1″ | Ex-V32-NPT1 | Ex-V32-G1 | 23-32 | 18-26 | 39 | 15 | 46 | 53 |
| M40*1.5 | Ex-V35-M40 | 1-1/4″ | Ex-V35-NPT1-1/4 | Ex-V35-G1-1/4 | 26-35 | 21-29 | 43 | 15 | 55 | 64 |
| M40*1.5 | Ex-V38-M40 | 1-1/4″ | Ex-V38-NPT1-1/4 | Ex-V38-G1-1/4 | 31-38 | 25-32 | 43 | 15 | 55 | 64 |
| M50*1.5 | Ex-V41-M50 | 1-1/2″ | Ex-V41-NPT1-1/2 | Ex-V41-G1-1/2 | 34-41 | 28-35 | 48 | 15 | 65 | 75 |
| M50*1.5 | Ex-V44-M50 | 1-1/2″ | Ex-V44-NPT1-1/2 | Ex-V44-G1-1/2 | 37-44 | 31-38 | 48 | 15 | 65 | 75 |
| M63*1.5 | Ex-V50-M63 | 2″ | Ex-V50-NPT2 | Ex-V50-G2 | 40-50 | 33-43 | 53 | 16 | 80 | 92 |
| M63*1.5 | Ex-V55-M63 | 2″ | Ex-V55-NPT2 | Ex-V55-G2 | 43-55 | 36-47 | 53 | 16 | 80 | 92 |
| M75*1.5 | Ex-V63-M75 | 2-1/2″ | Ex-V63-NPT2-1/2 | Ex-V63-G2 | 50-63 | 42-53 | 58 | 16 | 96 | 111 |
| M75*1.5 | Ex-V68-M75 | 2-1/2″ | Ex-V68-NPT2-1/2 | Ex-V68-G2-1/2 | 54-68 | 45-58 | 58 | 16 | 96 | 111 |
| M88*2 | Ex-V72-M88 | 3″ | Ex-V72-NPT3 | Ex-V72-G3 | 62-72 | 52-62 | 64 | 18 | 114 | 134 |
| M88*2 | Ex-V79-M88 | 3″ | Ex-V79-NPT3 | Ex-V79-G3 | 67-79 | 56-67 | 64 | 18 | 114 | 134 |
| M110,2 | Ex-V89-M110 | 4″ | Ex-V89-NPT4 | Ex-V89-G4 | 78-89 | 65-75 | 70 | 18 | 128 | 148 |
| M110,2 | Ex-V105-M110 | 4″ | Ex-V105-NPT4 | Ex-V105-G4 | 38-104.5 | 74-91 | 70 | 18 | 138 | 148 |
Ex-VIIG Double-Seal Armoured Cable Gland
Armour retention
Ex-VIIG Double-Seal Armoured Cable Gland
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M16 × 1.5 | Ex-VIIGM16 | 5-16 | 12 | 15 | 16 | 24 |
| M20 × 1.5 | Ex-VIIGM20 | 5-16 | 12 | 15 | 20 | 24 |
| M20 × 1.5D | Ex-VIIGM20D | 9-20 | 16 | 15 | 20 | 30 |
| M25 × 1.5 | Ex-VIIGM25 | 9-20 | 16 | 15 | 25 | 30 |
| M25 × 1.5D | Ex-VIIGM25D | 14-26 | 20 | 15 | 25 | 38 |
| M32 × 1.5 | Ex-VIIGM32 | 14-26 | 20 | 17 | 32 | 38 |
| M32 × 1.5D | Ex-VIIGM32D | 18-33 | 28 | 17 | 32 | 45 |
| M40 × 1.5 | Ex-VIIGM40-33 | 18-33 | 28 | 17 | 40 | 45 |
| M40 × 1.5D | Ex-VIIGM40D | 20-40 | 35 | 17 | 40 | 55 |
| M50 × 1.5 | Ex-VIIGM50 | 20-40 | 35 | 20 | 50 | 55 |
| M50 × 1.5D | Ex-VIIGM50D | 26-50 | 45 | 20 | 50 | 68 |
| M63 × 1.5 | Ex-VIIGM63 | 26-50 | 45 | 20 | 63 | 68 |
| M63 × 1.5D | Ex-VIIGM63D | 30-64 | 55 | 20 | 63 | 82 |
| M75 × 2 | Ex-VIIGM75 | 30-64 | 55 | 22 | 75 | 82 |
| M88 × 2 | Ex-VIIGM88 | 36-80 | 70 | 22 | 88 | 98 |
| M100 × 2 | Ex-VIIGM100 | 41-90 | 80 | 22 | 100 | 110 |
| M115 × 2 | Ex-VIIGM115 | 47-103 | 90 | 22 | 115 | 125 |
| M130 × 2 | Ex-VIIGM130 | 63-119 | 100 | 22 | 130 | 140 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| NPT 3/8 | Ex-VIIGNPT3/8 | 5-16 | 12 | 15 | 17.05 | 24 |
| NPT 1/2 | Ex-VIIGNPT1/2 | 5-16 | 12 | 15 | 21.22 | 24 |
| NPT 1/2D | Ex-VIIGNPT1/2D | 9-20 | 16 | 15 | 21.22 | 30 |
| NPT 3/4 | Ex-VIIGNPT3/4 | 9-20 | 16 | 15 | 26.56 | 30 |
| NPT 3/4D | Ex-VIIGNPT3/4D | 14-26 | 20 | 15 | 26.56 | 38 |
| NPT 1 | Ex-VIIGNPT1 | 14-26 | 20 | 17 | 33.28 | 38 |
| NPT 1D | Ex-VIIGNPT1D | 18-33 | 28 | 17 | 33.28 | 45 |
| NPT 1-1/4 | Ex-VIIGNPT1-1/4 | 18-33 | 28 | 17 | 41.98 | 45 |
| NPT 1-1/4D | Ex-VIIGNPT1-1/4D | 20-40 | 35 | 17 | 41.98 | 55 |
| NPT 1-1/2 | Ex-VIIGNPT1-1/2 | 20-40 | 35 | 20 | 48.05 | 55 |
| NPT 1-1/2D | Ex-VIIGNPT1-1/2D | 26-50 | 45 | 20 | 48.05 | 68 |
| NPT 2 | Ex-VIIGNPT2 | 26-50 | 45 | 20 | 60.09 | 68 |
| NPT 2D | Ex-VIIGNPT2D | 30-64 | 55 | 20 | 60.09 | 82 |
| NPT 2-1/2 | Ex-VIIGNPT2-1/2 | 30-64 | 55 | 22 | 72.69 | 82 |
| NPT 3 | Ex-VIIGNPT3 | 36-80 | 70 | 22 | 88.60 | 98 |
| NPT 4 | Ex-VIIGNPT4 | 47-103 | 90 | 22 | 113.97 | 125 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| G 3/8 | Ex-VIIGG3/8 | 5-16 | 12 | 15 | 16.66 | 24 |
| G 1/2 | Ex-VIIGG1/2 | 5-16 | 12 | 15 | 20.95 | 24 |
| G 1/2D | Ex-VIIGG1/2D | 9-20 | 16 | 15 | 20.95 | 30 |
| G 3/4 | Ex-VIIGG3/4 | 9-20 | 16 | 15 | 26.44 | 30 |
| G 3/4D | Ex-VIIGG3/4D | 14-26 | 20 | 15 | 26.44 | 38 |
| G 1 | Ex-VIIGG1 | 14-26 | 20 | 17 | 33.25 | 38 |
| G 1D | Ex-VIIGG1D | 18-33 | 28 | 17 | 33.25 | 45 |
| G 1-1/4 | Ex-VIIGG1-1/4 | 18-33 | 28 | 17 | 41.91 | 45 |
| G 1-1/4D | Ex-VIIGG1-1/4D | 20-40 | 35 | 17 | 41.91 | 55 |
| G 1-1/2 | Ex-VIIGG1-1/2 | 20-40 | 35 | 20 | 47.80 | 55 |
| G 1-1/2D | Ex-VIIGG1-1/2D | 26-50 | 45 | 20 | 47.80 | 68 |
| G 2 | Ex-VIIGG2 | 26-50 | 45 | 20 | 59.61 | 68 |
| G 2D | Ex-VIIGG2D | 30-64 | 55 | 20 | 59.61 | 82 |
| G 2-1/2 | Ex-VIIGG2-1/2 | 30-64 | 55 | 22 | 75.18 | 82 |
| G 3 | Ex-VIIGG3 | 36-80 | 70 | 22 | 87.88 | 98 |
| G 4 | Ex-VIIGG4 | 47-103 | 90 | 22 | 113.03 | 125 |
Ex-VIIIG Single-Seal Armoured Cable Gland
Armour retention
Ex-VIIIG Single-Seal Armoured Cable Gland
Model specificationsMetric thread
| Metric Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| M16 × 1.5 | Ex-VIIIGM16 | 5-16 | 12 | 15 | 16 | 24 |
| M20 × 1.5 | Ex-VIIIGM20 | 5-16 | 12 | 15 | 20 | 24 |
| M20 × 1.5D | Ex-VIIIGM20D | 9-20 | 16 | 15 | 20 | 30 |
| M25 × 1.5 | Ex-VIIIGM25 | 9-20 | 16 | 15 | 25 | 30 |
| M25 × 1.5D | Ex-VIIIGM25D | 14-26 | 20 | 15 | 25 | 38 |
| M32 × 1.5 | Ex-VIIIGM32 | 14-26 | 20 | 17 | 32 | 38 |
| M32 × 1.5D | Ex-VIIIGM32D | 18-33 | 28 | 17 | 32 | 45 |
| M40 × 1.5 | Ex-VIIIGM40-33 | 18-33 | 28 | 17 | 40 | 45 |
| M40 × 1.5D | Ex-VIIIGM40D | 20-40 | 35 | 17 | 40 | 55 |
| M50 × 1.5 | Ex-VIIIGM50 | 20-40 | 35 | 20 | 50 | 55 |
| M50 × 1.5D | Ex-VIIIGM50D | 26-50 | 45 | 20 | 50 | 68 |
| M63 × 1.5 | Ex-VIIIGM63 | 26-50 | 45 | 20 | 63 | 68 |
| M63 × 1.5D | Ex-VIIIGM63D | 30-64 | 55 | 20 | 63 | 82 |
| M75 × 2 | Ex-VIIIGM75 | 30-64 | 55 | 22 | 75 | 82 |
| M88 × 2 | Ex-VIIIGM88 | 36-80 | 70 | 22 | 88 | 98 |
| M100 × 2 | Ex-VIIIGM100 | 41-90 | 80 | 22 | 100 | 110 |
| M115 × 2 | Ex-VIIIGM115 | 47-103 | 90 | 22 | 115 | 125 |
| M130 × 2 | Ex-VIIIGM130 | 63-119 | 100 | 22 | 130 | 140 |
Model specificationsNPT thread
| NPT Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| NPT 3/8 | Ex-VIIIGNPT3/8 | 5-16 | 12 | 15 | 17.05 | 24 |
| NPT 1/2 | Ex-VIIIGNPT1/2 | 5-16 | 12 | 15 | 21.22 | 24 |
| NPT 1/2D | Ex-VIIIGNPT1/2D | 9-20 | 16 | 15 | 21.22 | 30 |
| NPT 3/4 | Ex-VIIIGNPT3/4 | 9-20 | 16 | 15 | 26.56 | 30 |
| NPT 3/4D | Ex-VIIIGNPT3/4D | 14-26 | 20 | 15 | 26.56 | 38 |
| NPT 1 | Ex-VIIIGNPT1 | 14-26 | 20 | 17 | 33.28 | 38 |
| NPT 1D | Ex-VIIIGNPT1D | 18-33 | 28 | 17 | 33.28 | 45 |
| NPT 1-1/4 | Ex-VIIIGNPT1-1/4 | 18-33 | 28 | 17 | 41.98 | 45 |
| NPT 1-1/4D | Ex-VIIIGNPT1-1/4D | 20-40 | 35 | 17 | 41.98 | 55 |
| NPT 1-1/2 | Ex-VIIIGNPT1-1/2 | 20-40 | 35 | 20 | 48.05 | 55 |
| NPT 1-1/2D | Ex-VIIIGNPT1-1/2D | 26-50 | 45 | 20 | 48.05 | 68 |
| NPT 2 | Ex-VIIIGNPT2 | 26-50 | 45 | 20 | 60.09 | 68 |
| NPT 2D | Ex-VIIIGNPT2D | 30-64 | 55 | 20 | 60.09 | 82 |
| NPT 2-1/2 | Ex-VIIIGNPT2-1/2 | 30-64 | 55 | 22 | 72.69 | 82 |
| NPT 3 | Ex-VIIIGNPT3 | 36-80 | 70 | 22 | 88.60 | 98 |
| NPT 4 | Ex-VIIIGNPT4 | 47-103 | 90 | 22 | 113.97 | 125 |
Model specificationsG thread
| G Thread | Model | Locking Range (mm) | Max. Outlet (mm) | Thread Length GL (mm) | Thread outside diameter AG (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|
| G 3/8 | Ex-VIIIGG3/8 | 5-16 | 12 | 15 | 16.66 | 24 |
| G 1/2 | Ex-VIIIGG1/2 | 5-16 | 12 | 15 | 20.95 | 24 |
| G 1/2D | Ex-VIIIGG1/2D | 9-20 | 16 | 15 | 20.95 | 30 |
| G 3/4 | Ex-VIIIGG3/4 | 9-20 | 16 | 15 | 26.44 | 30 |
| G 3/4D | Ex-VIIIGG3/4D | 14-26 | 20 | 15 | 26.44 | 38 |
| G 1 | Ex-VIIIGG1 | 14-26 | 20 | 17 | 33.25 | 38 |
| G 1D | Ex-VIIIGG1D | 18-33 | 28 | 17 | 33.25 | 45 |
| G 1-1/4 | Ex-VIIIGG1-1/4 | 18-33 | 28 | 17 | 41.91 | 45 |
| G 1-1/4D | Ex-VIIIGG1-1/4D | 20-40 | 35 | 17 | 41.91 | 55 |
| G 1-1/2 | Ex-VIIIGG1-1/2 | 20-40 | 35 | 20 | 47.80 | 55 |
| G 1-1/2D | Ex-VIIIGG1-1/2D | 26-50 | 45 | 20 | 47.80 | 68 |
| G 2 | Ex-VIIIGG2 | 26-50 | 45 | 20 | 59.61 | 68 |
| G 2D | Ex-VIIIGG2D | 30-64 | 55 | 20 | 59.61 | 82 |
| G 2-1/2 | Ex-VIIIGG2-1/2 | 30-64 | 55 | 22 | 75.18 | 82 |
| G 3 | Ex-VIIIGG3 | 36-80 | 70 | 22 | 87.88 | 98 |
| G 4 | Ex-VIIIGG4 | 47-103 | 90 | 22 | 113.03 | 125 |
Product comparison
Compare models
Compare the construction and application of each model.| Product | Construction | Use when | Check first | Review |
|---|---|---|---|---|
| BW Cable Gland for Indoor SWA Cable | BW Indoor Armoured Glands | An SWA cable requires a BW armour-lock construction for an indoor, dry location. |
| View specifications |
| CW Single-Compression Cable Gland for SWA | CW Armoured Cable Glands | An SWA cable installation requires a CW single-compression sealing construction. |
| View specifications |
| Ex-VII Double-Seal Armoured Cable Gland | Ex-VII Double-Seal Armoured Glands | An armoured cable requires the Ex-VII double-seal construction. |
| View specifications |
| Ex-V Single-Seal Armoured Cable Gland | Ex-V Single-Seal Armoured Glands | An armoured-cable installation calls for the Ex-V single-seal arrangement. |
| View specifications |
| Ex-VIIG Double-Seal Armoured Cable Gland | Ex-VIIG Double-Seal Armoured Glands | An armoured cable entry requires the Ex-VIIG double-seal arrangement. |
| View specifications |
| Ex-VIIIG Single-Seal Armoured Cable Gland | Ex-VIIIG Single-Seal Armoured Glands | An armoured cable requires the Ex-VIIIG single-seal construction. |
| View specifications |
Need a size that is not shown? Send us the cable diameter and entry thread.
Selection checks
Choose the right size and construction
Measure the cable diameter and identify the enclosure thread. These details determine which gland will fit.
- Armour type and diameterIdentify the armour type and measure its diameter so the clamp fits the cable.
- Bedding and outer-sheath diametersMeasure each cable layer where a seal will sit; the inner and outer seals can have different ranges.
- Entry, bonding and accessory needsMatch the entry thread and armour-bonding arrangement. Include any earth tag, locknut or shroud required by the installation.
Product support
Need help choosing a cable gland?
Send a model name, a photo or a short question. We can help with sizes, samples and a quotation. If you have them, the details below help us narrow down the options.
Request product support- CableOutside diameter and cable type, if known.
- Armour or screenA cable cross-section photo can help identify the construction.
- Equipment entryThread marking, hole size or an entry drawing.
- Body and sealTell us if your project specifies a material.
- InstallationDescribe where the gland will be used and any heat, water or chemical exposure.
- Project requirementsInclude any required standard or certificate reference.
- Model or photoStart with a model number, a photo or a short question.
Armoured Cable Glands FAQ
Cable gland questions
Find answers about fit, assembly and product differences.
Armoured Cable Glands
01Why are bedding and outer-sheath diameters both needed?
The bedding lies beneath the armour; the outer sheath covers it. Gland components contact different cable layers, so a single overall diameter does not describe every sealing and clamping surface.
02Can one gland fit every type of cable armour?
No. Wire armour, tape armour and braid have different shapes and clamping needs. Match the gland construction to the armour type and its dimensions.
BW Cable Gland for Indoor SWA Cable
BW Cable Gland for Indoor SWA Cable
01How does BW differ from CW?
BW is the indoor, dry-location two-part armour-lock form with an IP30 specification. CW is a single-compression construction with IP66/IP67 specifications. Their sealing arrangements are different.
02Which cable dimensions identify a BW size?
The armour construction and diameter must fit the armour lock. The cable bedding, overall dimensions and enclosure thread identify the rest of the assembly.
CW Single-Compression Cable Gland for SWA
CW Single-Compression Cable Gland for SWA
01Why choose CW instead of BW?
BW is intended for indoor, dry locations with an IP30 specification. CW uses a single-compression construction with IP66/IP67 specifications. Choose the construction that matches the cable sealing and installation conditions.
02Does the CW name establish hazardous-area approval?
No. Hazardous-area use requires a current certificate covering the exact gland, cable construction and installation. A CW designation or an IP rating is not that approval.
Ex-VII Double-Seal Armoured Cable Gland
Ex-VII Double-Seal Armoured Cable Gland
01Which armoured cable types does Ex-VII cover?
The construction is intended for steel-wire, braided and steel-tape armoured cables. Each cable’s dimensions must fit the sealing and armour-clamping ranges of the chosen size.
02How does Ex-VII differ from a single-seal gland?
Ex-VII uses a double-seal construction. It should be selected using the dimensions of both sealing interfaces as well as the armour-clamping arrangement.
03What is needed for hazardous-area use?
The exact Ex-VII configuration needs a current certificate matching the equipment protection concept, cable and installation. The model name does not establish that scope.
04How do I select an Ex-VII size?
Compare the cable range, maximum outlet diameter and entry thread. For example, Ex-VIIM20D has a 9–20 mm cable range and a 16 mm maximum outlet.
Ex-V Single-Seal Armoured Cable Gland
Ex-V Single-Seal Armoured Cable Gland
01How does Ex-V differ from Ex-VII?
Ex-V is the single-seal construction; Ex-VII is a double-seal construction. Their sealing arrangements and dimensional requirements are different.
02Is the Ex-V rating the same for every material option?
A rating cannot be assigned from the model name alone. The body, seal, cable and protection configuration must be identified together before an ingress, temperature or hazardous-area rating is specified.
Ex-VIIG Double-Seal Armoured Cable Gland
Ex-VIIG Double-Seal Armoured Cable Gland
01Why does double sealing need more cable measurements?
Each sealing interface must fit the cable layer it contacts. Armour-clamping dimensions remain a separate part of the size selection.
02Is Ex-VIIG the same as Ex-VIIIG?
No. Ex-VIIG is the double-seal model, while Ex-VIIIG is the single-seal model. Keep the complete model designation with the dimensional and certificate requirements.
03How do I select an Ex-VIIG size?
Compare the cable range, maximum outlet diameter and entry thread. For example, Ex-VIIGM20D has a 9–20 mm cable range and a 16 mm maximum outlet.
Ex-VIIIG Single-Seal Armoured Cable Gland
Ex-VIIIG Single-Seal Armoured Cable Gland
01What is the difference between Ex-VIIIG and Ex-VIIG?
Ex-VIIIG is the single-seal version. Ex-VIIG uses double sealing. The required cable layers and sealing dimensions must be matched to the chosen construction.
02Can it be chosen only from the armour type?
No. Wire, braid or tape armour identifies the construction family, but the armour diameter and cable sealing dimensions identify the size.
03Does the model name establish the permitted zone?
No. Zone and protection requirements must be matched to the current certificate for the exact model and configuration.
04How do I select an Ex-VIIIG size?
Compare the cable range, maximum outlet diameter and entry thread. For example, Ex-VIIIGM20D has a 9–20 mm cable range and a 16 mm maximum outlet.