08 / Hose and conduit connections
Hose and Conduit Fittings
Hose and conduit fittings hold the conduit at an equipment entry or join two conduit sections. Choose the fitting for flexible hose, EMT, IMC or the other conduit system in your installation, then match the size and connection ends.
- Conduit type and nominal size
- Fitting and entry thread
- Bend space and sealing duty
Cable gland families
Compare cable glands by material, cable construction and duty.
Choose nylon, brass or stainless steel by body material, or compare EMC, armoured, hazardous-area, marine and conduit-entry designs by the job they must perform.
Hose and Conduit Fittings range
Choose your hose and conduit fittings
Straight and angled fittings for connecting conduit to boxes, enclosures and other conduit sections.
Models & dimensions
Hose and Conduit Fittings: specifications and dimensions
Select a product to see its specifications, drawings and sizes.
Hose and Conduit Fittings
Which fitting do you need?
Choose a product above, or show all products to compare sizes and construction.- 01Conduit type and size
- 02Entry thread and dimensions
- 03Material and installation duty
BH-Series Brass Hose Connector
01 / Hose and conduit connections
BH-Series Brass Hose Connector
A BH-series nickel-plated brass hose connector with a brass ferrule and sealing components for flexible protective tubing.
Product reference
- Construction
- BH Quick-Install Hose Connectors
- Application
- Join flexible protective tubing with a brass-body connector and ferrule.
Key specifications
- Series
- BH Series
- Body Material
- Nickel-Plated Brass
- Ferrule
- Brass
- Seal
- NBR (Nitrile Rubber) / PA6
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Sealing Ring
- Thermoplastic Elastomer (TPE) or PTFE
- Protection Rating
- IP65
- Temperature Range (Static)
- -40°C to 100°C (up to 120°C for short periods)
Key features
- Brass body and ferruleThe BH construction uses a nickel-plated brass body and a brass ferrule.
- Sealing-component optionsThe range lists NBR/PA6 components and TPE or PTFE sealing-ring options.
MH-Series Brass Fitting for Flexible Conduit
02 / Hose and conduit connections
MH-Series Brass Fitting for Flexible Conduit
An MH-series brass fitting for SPR, Agraff and coated flexible-conduit systems.
Product reference
- Construction
- MH Brass Conduit Fittings
- Application
- The flexible-conduit system requires a matching MH ferrule-and-seal fitting.
Key specifications
- Series
- MH Series
- Application
- SPR-AS, FEXAgraff-AS, SOR-PVC-AS, SPR-PU-AS Conduits
- Body Material
- Nickel-Plated Brass
- Ferrule
- Brass
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Seal
- NBR, PA6
- Sealing Ring
- Thermoplastic Elastomer (TPE) or PTFE
- Protection Rating
- IP65
- Static Temperature
- -40°C to 100°C (short term to 120°C)
- Dynamic Temperature
- -20°C to 80°C (short term to 100°C)
Key features
- Conduit-system selectionThe MH range identifies SPR-AS, FEXAgraff-AS, SOR-PVC-AS and SPR-PU-AS conduit applications.
- Brass body and ferruleA nickel-plated brass body and brass ferrule form the mechanical connection.
- Seal optionsNBR/PA6 components are paired with TPE or PTFE sealing-ring options.
DPJ Zinc Die-Cast Flex-to-Box Connector
03 / Hose and conduit connections
DPJ Zinc Die-Cast Flex-to-Box Connector
A DPJ zinc die-cast fitting that connects flexible metal conduit to a threaded box or enclosure entry.
Product reference
- Construction
- DPJ Male-Thread Fittings
- Application
- A flexible-metal-conduit run needs a male-threaded connection to a box.
Key specifications
- Product Type
- Zinc Die Cast Flex to Box Connector
- Model Series
- DPJ
- Body Material
- Zinc Alloy, Die-Cast
- Ferrule
- Galvanized Iron/Zinc
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.

Section view and dimension markers
Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.
Drawing markers: H · GL · AG
Model specification tablesFurther specifications
- Ingress Protection
- IP66
- Operating Temperature
- -40°C to +100°C
- Body Shape
- Hexagonal
Key features
- Flex-to-box connectionThe fitting joins flexible metal conduit to the equipment entry.
- Zinc die-cast bodyThe body has a hexagonal form for tightening access.
- Ferrule connectionA metal ferrule forms part of the conduit-retention assembly.
DPJ Stainless-Steel Flex-to-Box Connector
04 / Hose and conduit connections
DPJ Stainless-Steel Flex-to-Box Connector
A stainless-steel DPJ fitting for connecting flexible metal conduit to a box or enclosure entry.
Product reference
- Construction
- Stainless Flex-to-Box Fittings
- Application
- A flex-to-box connection requires the stainless-steel DPJ body option.
Key specifications
- Product Type
- Stainless Steel Flex to Box Connector
- Model Series
- DPJ
- Body Material
- Stainless Steel (304, 316)
- Ingress Protection
- IP66
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Operating Temperature
- -40°C to +100°C
- Body Shape
- Hexagonal
Key features
- Stainless-steel bodyThe range includes 304 and 316 body options.
- Hexagonal fitting formThe body provides flats for tightening at the equipment entry.
- Flexible-conduit connectionA ferrule arrangement retains the conduit at the fitting.
DPN Zinc Die-Cast Flex-to-IMC Connector
05 / Hose and conduit connections
DPN Zinc Die-Cast Flex-to-IMC Connector
A DPN zinc die-cast connector for joining flexible metal conduit to threaded intermediate metal conduit (IMC).
Product reference
- Construction
- DPN Flex-to-IMC Connectors
- Application
- A flexible conduit run needs to join a threaded IMC connection.
Key specifications
- Product Type
- Zinc Die Cast Flex to IMC Connector
- Model Series
- DPN
- Body Material
- Zinc Alloy, Die-Cast
- Operating Temperature
- -40°C to +100°C
Product specifications
Construction and details
Further specifications
- Application
- Connecting Flexible Metal Conduit to threaded IMC
- Body Shape
- Hexagonal
Key features
- Flex-to-IMC connectionThe DPN construction joins flexible metal conduit to threaded IMC.
- Zinc die-cast bodyThe metal body has a hexagonal tightening form.
DPN Stainless-Steel Female-Thread Conduit Connector
06 / Hose and conduit connections
DPN Stainless-Steel Female-Thread Conduit Connector
A stainless-steel DPN fitting with a female thread for joining flexible metal conduit to threaded IMC.
Product reference
- Construction
- DPN Stainless Female-Thread Connectors
- Application
- A flex-to-IMC connection needs a stainless-steel body and a female-threaded end.
Key specifications
- Product Type
- Stainless Steel Flex to IMC Connector
- Model Series
- DPN
- Body Material
- Stainless Steel (304 / 316)
- Ingress Protection
- IP66
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Operating Temperature
- -40°C to +100°C
- Thread Type
- Female Thread (NPT, G, Metric as options)
- Application
- Flexible metal conduit to threaded IMC
- Body Shape
- Hexagonal
Key features
- Female-threaded IMC endThe internal thread receives the matching threaded IMC connection.
- Stainless-steel body options304 and 316 body versions are available.
- Hexagonal bodyFlats on the body provide tightening access.
DKJ Zinc Set-Screw Flex-to-EMT Connector
07 / Hose and conduit connections
DKJ Zinc Set-Screw Flex-to-EMT Connector
A DKJ zinc die-cast fitting with a set-screw EMT connection and a nut-and-ferrule connection for flexible metal conduit.
Product reference
- Construction
- EMT Set-Screw Fittings
- Application
- A flexible conduit must join plain EMT using a set-screw fitting.
Key specifications
- Product Type
- Zinc Die Cast Flex to EMT Connector
- Model Series
- DKJ
- Body Material
- Zinc Alloy, Die-Cast
- Ingress Protection
- IP54
Product specifications
Construction and details
Further specifications
- Operating Temperature
- -40°C to +100°C
- EMT Connection Type
- Set Screw (Self-Fastening)
- Flex Connection Type
- Threaded Nut with Ferrule
- Application
- Connecting Flexible Metal Conduit to unthreaded EMT
Key features
- Set-screw EMT endThe EMT connection is retained by a set screw.
- Nut-and-ferrule flex endThe flexible-conduit end uses a threaded nut and ferrule.
- Zinc die-cast bodyThe fitting provides a metal transition between the two conduit forms.
DKJ Stainless-Steel Set-Screw Flex-to-EMT Connector
08 / Hose and conduit connections
DKJ Stainless-Steel Set-Screw Flex-to-EMT Connector
A stainless-steel DKJ fitting with a set-screw connection to EMT and a nut-and-ferrule connection to flexible conduit.
Product reference
- Construction
- DKJ Flex-to-EMT Fittings
- Application
- A set-screw flex-to-EMT connection requires a stainless-steel body.
Key specifications
- Product Type
- Stainless Steel Flex to EMT Connector
- Model Series
- DKJ
- Body Material
- Stainless Steel (304 / 316)
- Ingress Protection
- IP68
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Operating Temperature
- -40°C to +120°C
- EMT Connection Type
- Set Screw (Self-Fastening)
- Flex Connection Type
- Threaded Nut with Ferrule
- Application
- Flexible metal conduit to unthreaded EMT
Key features
- Set-screw EMT retentionA set screw secures the plain EMT end.
- Separate flex connectionA threaded nut and ferrule retain the flexible metal conduit.
- Stainless body choicesThe range includes 304 and 316 stainless-steel bodies.
DGJ Zinc Compression Flex-to-EMT Connector
09 / Hose and conduit connections
DGJ Zinc Compression Flex-to-EMT Connector
A DGJ zinc die-cast fitting that joins flexible conduit to EMT through a compression nut and ring.
Product reference
- Construction
- DGJ Zinc Compression Fittings
- Application
- A flex-to-EMT connection calls for a compression fitting at the EMT end.
Key specifications
- Product Type
- Zinc Die Cast Flex to EMT Compression Connector
- Model Series
- DGJ
- Body Material
- Zinc Alloy, Die-Cast
- Ingress Protection
- IP66
Product specifications
Construction and details
Further specifications
- Operating Temperature
- -40°C to +100°C
- EMT Connection Type
- Compression Nut with Ring
- Flex Connection Type
- Threaded Nut with Ferrule
- Application
- Connecting Flexible Metal Conduit to unthreaded EMT
Key features
- Compression EMT endA nut and ring retain the EMT connection.
- Nut-and-ferrule flex endThe flexible-conduit connection uses a threaded nut with a ferrule.
- Zinc die-cast bodyThe body joins the two different conduit-retention arrangements.
DGJ Stainless-Steel Compression Flex-to-EMT Connector
10 / Hose and conduit connections
DGJ Stainless-Steel Compression Flex-to-EMT Connector
A stainless-steel DGJ fitting with compression-ring retention for EMT and a separate nut-and-ferrule flex connection.
Product reference
- Construction
- Stainless Flex-to-EMT Compression Fittings
- Application
- A compression flex-to-EMT connection needs a stainless-steel body.
Key specifications
- Product Type
- Stainless Steel Flex to EMT Compression Connector
- Model Series
- DGJ
- Body Material
- Stainless Steel (304 / 316)
- Ingress Protection
- IP68
Product specifications
Construction and details

Separated assembly components
Compare the arrangement of the illustrated parts. Confirm the assembly instructions for the selected model.
Further specifications
- Operating Temperature
- -40°C to +120°C
- EMT Connection Type
- Compression Nut with Ring
- Flex Connection Type
- Threaded Nut with Ferrule
- Application
- Flexible metal conduit to unthreaded EMT
Key features
- Compression-ring EMT connectionThe nut and ring clamp the plain EMT end.
- Independent flex retentionA separate nut and ferrule retain the flexible conduit.
- 304 and 316 optionsThe body is available in these two stainless-steel grades.
DWJ 90-Degree Flexible-Conduit Connector
11 / Hose and conduit connections
DWJ 90-Degree Flexible-Conduit Connector
A DWJ zinc die-cast fitting that turns flexible metal conduit through 90 degrees into a matching female-threaded enclosure entry.
Product reference
- Construction
- DWJ Right-Angle Conduit Fittings
- Application
- A flexible conduit needs a right-angle approach to a threaded box or enclosure.
Key specifications
- Product Type
- Zinc Die Cast 90-Degree Flexible Conduit Connector
- Model Series
- DWJ
- Body Material
- Zinc Alloy, Die-Cast
- Angle
- 90 Degrees
Product specifications
Construction and details
Further specifications
- Ingress Protection
- IP66
- Operating Temperature
- -40°C to +100°C
- System Connection
- Male Thread (NPT, G, Metric as options)
- Conduit Connection
- Threaded Nut with Ferrule
- Application
- Connecting Flexible Metal Conduit to a threaded entry at a 90-degree angle
Key features
- 90-degree bodyThe elbow changes the conduit direction close to the equipment entry.
- Male-threaded equipment endThe fitting uses a male thread at the system connection.
- Nut-and-ferrule conduit endThe flexible conduit is retained by a threaded nut and ferrule.
Model specification tables
Model sizes
BH-Series Brass Hose Connector
Hose and conduit connections
BH-Series Brass Hose Connector
Model specificationsMetric thread
| Model | Φ1 (mm) | Entry thread | Fits to tubing size | ΦB (mm) | c | D | SWl | SW2 |
|---|---|---|---|---|---|---|---|---|
| M10-BH | 6.5 | M10X1.0 | AD10 | 19 | 10 | 31 | 15 | 17 |
| M12-BH | 9.0 | M12X1.5 | AD14 | 23 | 10 | 33 | 19 | 21 |
| M16-BH | 12.5 | M16X1.5 | AD17 | 27 | 10 | 33 | 23 | 25 |
| M20-BH | 16.0 | M20X1.5 | AD21 | 31 | 10 | 33 | 27 | 29 |
| M25-BH | 21.0 | M25X1.5 | AD27 | 39 | 11 | 41 | 34 | 36 |
| M32-BH | 27.5 | M32X1.5 | AD36 | 48 | 13 | 43 | 43 | 45 |
| M40-BH | 35.5 | M40X1.5 | AD45 | 57 | 13 | 43 | 52 | 54 |
| M50-BH | 45.5 | M50X1.5 | AD56 | 70 | 14 | 49 | 63 | 66 |
| M63-BH | 49.0 | M63X1.5 | AD56 | 70 | 14 | 49 | 63 | 66 |
Model specificationsPG thread
| Model | Φ1 (mm) | Entry thread | Fits to tubing size | ΦB (mm) | c | D | SWl | SW2 |
|---|---|---|---|---|---|---|---|---|
| PG7-BH | 6.5 | PG7 | AD10 | 19 | 7 | 28 | 15 | 17 |
| PG9-BH | 10.0 | PG9 | AD14 | 23 | 7 | 30 | 19 | 21 |
| PG11-BH | 12.5 | PG11 | AD17 | 27 | 7 | 30 | 23 | 25 |
| PG13-BH | 14.5 | PG13.5 | AD19 | 29 | 7 | 30 | 25 | 27 |
| PG16-BH | 16.0 | PG16 | AD21 | 31 | 7 | 30 | 27 | 29 |
| PG21-BH | 21.0 | PG21 | AD27 | 39 | 10 | 40 | 34 | 36 |
| PG29-BH | 29.0 | PG29 | AD36 | 48 | 10 | 40 | 43 | 45 |
| PG36-BH | 38.0 | PG36 | AD45 | 57 | 10 | 40 | 52 | 54 |
| PG48-BH | 49.0 | PG48 | AD56 | 70 | 10 | 45 | 63 | 66 |
MH-Series Brass Fitting for Flexible Conduit
Hose and conduit connections
MH-Series Brass Fitting for Flexible Conduit
Model specificationsMetric thread
| Model | Entry thread | Card pin range | Thread length (mm) | Spanner size (mm) | Conduit nominal inside diameter (mm) |
|---|---|---|---|---|---|
| M12-MH | M 12X1.5 | 3-6.5 | 7 | 20 | Φ6 |
| M16-MH | M16X1.5 | 4-8 | 8 | 22 | Φ8 |
| M18-MH | M 18X1.5 | 5-10 | 8 | 24 | Φ10 |
| M20-MH | M20X1.5 | 6-12 | 8 | 26 | Φ12 |
| M22-MH | M20X1.5 | 10-14 | 8 | 30 | Φ15 |
| M24-MH | M24X1.5 | 10-14 | 9 | 30 | Φ15 |
| M25-MH | M 25X1.5 | 10-16 | 9 | 30 | Φ15 |
| M27-MH | M27X2.0 | 13-18 | 9 | 36 | Φ20 |
| M30-MH | M30X2.0 | 13-18 | 9 | 36 | Φ20 |
| M32-MH | M32X1.5 | 15-22 | 10 | 36 | Φ20 |
| M36-MH | M36X2.0 | 18-25 | 10 | 43 | Φ25 |
| M40-MH | M40X1.5 | 22-30 | 11 | 52 | Φ32 |
| M48-MH | M48X2.0 | 25-32 | 11 | 55 | Φ32 |
| M50-MH | M50X1.5 | 32-38 | 12 | 60 | Φ38 |
| M56-MH | M56X2.0 | 32-38 | 12 | 60 | Φ38 |
Model specificationsPG thread
| Model | Entry thread | Card pin range | Thread length (mm) | Spanner size (mm) | Conduit nominal inside diameter (mm) |
|---|---|---|---|---|---|
| PG7-MH | PG7 | 3-6.5 | 7 | 20 | Φ6 |
| PG9-MH | PG9 | 4-8 | 8 | 22 | Φ8 |
| PG11-MH | PG11 | 5-10 | 8 | 24 | Φ10 |
| PG13.5-MH | PG13.5 | 6-12 | 8 | 26 | Φ12 |
| PG16-MH | PG16 | 8-16 | 8 | 30 | Φ15 |
| PG21-MH | PG21 | 13-18 | 9 | 36 | Φ20 |
| PG29-MH | PG29 | 18-25 | 11 | 43 | Φ25 |
| PG36-MH | PG36 | 25-32 | 12 | 52 | Φ32 |
| PG42-MH | PG42 | 32-38 | 13 | 60 | Φ38 |
| PG48-MH | PG48 | 37-44 | 14 | 60 | Φ38 |
DPJ Zinc Die-Cast Flex-to-Box Connector
Hose and conduit connections
DPJ Zinc Die-Cast Flex-to-Box Connector
Model specificationsDPJ Zinc Die-Cast Flex-to-Box Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
DPJ Stainless-Steel Flex-to-Box Connector
Hose and conduit connections
DPJ Stainless-Steel Flex-to-Box Connector
Model specificationsDPJ Stainless-Steel Flex-to-Box Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
DPN Zinc Die-Cast Flex-to-IMC Connector
Hose and conduit connections
DPN Zinc Die-Cast Flex-to-IMC Connector
Model specificationsDPN Zinc Die-Cast Flex-to-IMC Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
DPN Stainless-Steel Female-Thread Conduit Connector
Hose and conduit connections
DPN Stainless-Steel Female-Thread Conduit Connector
Model specificationsDPN Stainless-Steel Female-Thread Conduit Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
DKJ Zinc Set-Screw Flex-to-EMT Connector
Hose and conduit connections
DKJ Zinc Set-Screw Flex-to-EMT Connector
Model specificationsDKJ Zinc Set-Screw Flex-to-EMT Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
DKJ Stainless-Steel Set-Screw Flex-to-EMT Connector
Hose and conduit connections
DKJ Stainless-Steel Set-Screw Flex-to-EMT Connector
Model specificationsDKJ Stainless-Steel Set-Screw Flex-to-EMT Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
DGJ Zinc Compression Flex-to-EMT Connector
Hose and conduit connections
DGJ Zinc Compression Flex-to-EMT Connector
Model specificationsDGJ Zinc Compression Flex-to-EMT Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
DGJ Stainless-Steel Compression Flex-to-EMT Connector
Hose and conduit connections
DGJ Stainless-Steel Compression Flex-to-EMT Connector
Model specificationsDGJ Stainless-Steel Compression Flex-to-EMT Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
DWJ 90-Degree Flexible-Conduit Connector
Hose and conduit connections
DWJ 90-Degree Flexible-Conduit Connector
Model specificationsDWJ 90-Degree Flexible-Conduit Connector — thread and cable dimensions
| Conduit size | G thread | Mounting hole for G thread (mm) | Metric thread | Mounting hole for Metric thread (mm) |
|---|---|---|---|---|
| Φ6 | G1/4 | 13.3 | M14*1.5 | 14.2 |
| Φ8 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ10 | G3/8 | 16.8 | M16*1.5 | 16.2 |
| Φ12 | G3/8 | 16.8 | M20*1.5 | 20.2 |
| Φ16 | G1/2 | 21.2 | M20*1.5 | 20.2 |
| Φ20 | G3/4 | 26.6 | M25*1.5 | 25.2 |
| Φ25 | G1 | 33.5 | M32*1.5 | 32.3 |
| Φ32 | G1-1/4 | 42.2 | M40*1.5 | 40.3 |
| Φ38 | G1-1/2 | 48 | M50*1.5 | 50.3 |
| Φ51 | G2 | 60 | M60*2 | 60.3 |
| Φ64 | G2-1/2 | 75.5 | M72*2 | 72.5 |
| Φ75 | G3 | 88.5 | M88*2 | 88.5 |
| Φ100 | G4 | 114 | M114*2 | 115 |
Product comparison
Compare models
Compare the construction and application of each model.| Product | Construction | Use when | Check first | Review |
|---|---|---|---|---|
| BH-Series Brass Hose Connector | BH Quick-Install Hose Connectors | Join flexible protective tubing with a brass-body connector and ferrule. |
| View specifications |
| MH-Series Brass Fitting for Flexible Conduit | MH Brass Conduit Fittings | The flexible-conduit system requires a matching MH ferrule-and-seal fitting. |
| View specifications |
| DPJ Zinc Die-Cast Flex-to-Box Connector | DPJ Male-Thread Fittings | A flexible-metal-conduit run needs a male-threaded connection to a box. |
| View specifications |
| DPJ Stainless-Steel Flex-to-Box Connector | Stainless Flex-to-Box Fittings | A flex-to-box connection requires the stainless-steel DPJ body option. |
| View specifications |
| DPN Zinc Die-Cast Flex-to-IMC Connector | DPN Flex-to-IMC Connectors | A flexible conduit run needs to join a threaded IMC connection. |
| View specifications |
| DPN Stainless-Steel Female-Thread Conduit Connector | DPN Stainless Female-Thread Connectors | A flex-to-IMC connection needs a stainless-steel body and a female-threaded end. |
| View specifications |
| DKJ Zinc Set-Screw Flex-to-EMT Connector | EMT Set-Screw Fittings | A flexible conduit must join plain EMT using a set-screw fitting. |
| View specifications |
| DKJ Stainless-Steel Set-Screw Flex-to-EMT Connector | DKJ Flex-to-EMT Fittings | A set-screw flex-to-EMT connection requires a stainless-steel body. |
| View specifications |
| DGJ Zinc Compression Flex-to-EMT Connector | DGJ Zinc Compression Fittings | A flex-to-EMT connection calls for a compression fitting at the EMT end. |
| View specifications |
| DGJ Stainless-Steel Compression Flex-to-EMT Connector | Stainless Flex-to-EMT Compression Fittings | A compression flex-to-EMT connection needs a stainless-steel body. |
| View specifications |
| DWJ 90-Degree Flexible-Conduit Connector | DWJ Right-Angle Conduit Fittings | A flexible conduit needs a right-angle approach to a threaded box or enclosure. |
| View specifications |
Need a size that is not shown? Send us the conduit type, size and the connection at each end.
Selection checks
Choose the right size and construction
Identify the conduit type, profile and nominal size, then match the connection at each end of the fitting.
- Conduit type and nominal sizeMatch the fitting to the conduit system, profile and nominal size, rather than the cable inside it.
- Fitting and entry threadIdentify both connection ends: conduit, threaded enclosure entry or another conduit fitting.
- Bend space and sealing dutyLeave room for the conduit bend and assembly tools, and choose the sealing arrangement for the installation.
Product support
Need help choosing a conduit fitting?
Send a model name, a photo or a short question. We can help with sizes, samples and a quotation. If you have them, the details below help us narrow down the options.
Request product support- CableOutside diameter and cable type, if known.
- Armour or screenA cable cross-section photo can help identify the construction.
- Equipment entryThread marking, hole size or an entry drawing.
- Body and sealTell us if your project specifies a material.
- InstallationDescribe where the gland will be used and any heat, water or chemical exposure.
- Project requirementsInclude any required standard or certificate reference.
- Model or photoStart with a model number, a photo or a short question.
Hose and Conduit Fittings FAQ
Conduit fitting questions
Find answers about fit, assembly and product differences.
Hose and Conduit Fittings
01Can I choose a conduit fitting by the cable diameter?
Choose it by the conduit type and size. The fitting grips the conduit rather than the cable inside it, and different conduit systems can use different connection methods.
02When should I use an angled fitting?
An angled fitting turns the conduit close to the enclosure. Check the exit direction and the space needed to assemble the fitting and bend the conduit without straining it.
BH-Series Brass Hose Connector
BH-Series Brass Hose Connector
01What identifies a BH connector size?
The tubing profile and size identify the hose end. The equipment-entry dimensions identify the other end; the cable inside the tubing does not determine the fitting size.
02Does the BH name mean every seal option has the same operating limits?
No. The seal and sealing-ring combination forms part of the selected model. Include that combination with the required temperature and exposure conditions.
MH-Series Brass Fitting for Flexible Conduit
MH-Series Brass Fitting for Flexible Conduit
01Can MH be selected only from a conduit’s nominal diameter?
No. The conduit system and profile must also match. Include the complete conduit designation with the nominal size.
02Why are static and dynamic temperatures listed separately?
A fixed run and a moving conduit run impose different duties. Use the limit for the actual movement and the selected sealing components.
DPJ Zinc Die-Cast Flex-to-Box Connector
DPJ Zinc Die-Cast Flex-to-Box Connector
01What is the difference between DPJ and DPN?
DPJ is the flex-to-box construction. DPN connects flexible conduit to threaded IMC, so the equipment-side connection is different.
02Which thread should be specified for DPJ?
Give the complete designation of the box entry. The available thread system must be matched to the chosen DPJ size; it is not identified by the DPJ name alone.
DPJ Stainless-Steel Flex-to-Box Connector
DPJ Stainless-Steel Flex-to-Box Connector
01Does a stainless-steel body mean the ferrule is also stainless?
Not necessarily. The ferrule material must be specified separately from the body grade.
02What information is needed to match the box entry?
Provide the complete box-entry thread and the flexible-conduit designation and size. The DPJ model name alone does not identify the thread.
DPN Zinc Die-Cast Flex-to-IMC Connector
DPN Zinc Die-Cast Flex-to-IMC Connector
01Can DPN connect directly to plain, unthreaded EMT?
DPN is the threaded-IMC construction. The DKJ and DGJ forms use different arrangements for unthreaded EMT.
02What does a DPN order need besides the conduit size?
Identify the IMC thread and the flexible-conduit type at the opposite end. Specify any required ingress protection so it can be matched to the assembled connection.
DPN Stainless-Steel Female-Thread Conduit Connector
DPN Stainless-Steel Female-Thread Conduit Connector
01Which side has the female thread?
The IMC connection uses the female thread. The opposite end retains the flexible metal conduit.
02Does 316 automatically make the complete fitting suitable for a cleaning process?
No. The conduit, ferrule and sealing parts also contact the environment. Match their materials to the cleaning chemicals, temperature and exposure.
DKJ Zinc Set-Screw Flex-to-EMT Connector
DKJ Zinc Set-Screw Flex-to-EMT Connector
01How does DKJ differ from DGJ?
DKJ uses a set screw at the EMT end. DGJ uses a compression nut and ring at that end.
02Does this connect to threaded IMC?
This DKJ construction connects to unthreaded EMT. Threaded IMC uses a different connection form, such as the DPN arrangement.
DKJ Stainless-Steel Set-Screw Flex-to-EMT Connector
DKJ Stainless-Steel Set-Screw Flex-to-EMT Connector
01Is the DKJ EMT connection a compression ring?
No. DKJ uses a set screw. The DGJ construction is the compression-nut-and-ring alternative.
02Does the IP68 rating apply before both conduits are assembled?
No. Ingress protection applies to the complete installed assembly with the specified conduits and sealing parts, not to a loose fitting with open ends.
DGJ Zinc Compression Flex-to-EMT Connector
DGJ Zinc Compression Flex-to-EMT Connector
01Which end uses the compression ring?
The EMT end uses the compression nut and ring. The flexible-conduit end uses its own threaded nut and ferrule.
02Can the DGJ and DKJ assembly methods be mixed?
No. DGJ compression and DKJ set-screw parts use different retention methods. Assemble the complete fitting with its own components.
DGJ Stainless-Steel Compression Flex-to-EMT Connector
DGJ Stainless-Steel Compression Flex-to-EMT Connector
01How does this differ from the stainless DKJ fitting?
DGJ uses a compression nut and ring at the EMT end. Stainless DKJ uses a set screw there.
02Are the body grade and sealing parts one material choice?
No. The 304 or 316 designation identifies the body. The ferrule and sealing components must also suit the conduit and installation environment.
DWJ 90-Degree Flexible-Conduit Connector
DWJ 90-Degree Flexible-Conduit Connector
01Does DWJ use the same EMT connection as DKJ?
No. DWJ has a male-threaded equipment end and a 90-degree body. DKJ uses a set-screw connection to plain EMT.
02What clearance is needed for the elbow?
Allow space for the body to turn during installation, access to the tightening flats and the conduit’s bend beyond the outlet.