Engineering Calculator · 122
PV String Voltage & Parallel Current Calculator
Calculate series-string voltage, a linear cold-Voc estimate and parallel reference currents for identical PV modules and strings.
Live calculation
Enter the known values.
Units remain visible beside every field and result. Change any input to recalculate immediately in your browser.
Results
The calculation runs locally in this browser. Values are not submitted or stored by this tool.
Direct answer
What this result means
Series-connected matched modules add voltage; parallel matched strings add current. Cold string Voc uses the module’s signed Voc temperature coefficient and minimum cell temperature. Ten 40 V modules with −0.3%/°C coefficient at −10°C instead of 25°C give a linear estimate of 442 V open circuit.
Formula & theory
Make the assumptions visible.
Module datasheet Voc, Vmp, Isc and Imp must share reference conditions. Ns counts modules per series string and Np counts identical parallel strings. The coefficient is entered as signed percent per degree Celsius. The other-string current is (Np − 1)Isc at the reference conditions, not a complete reverse-fault or fuse-sizing calculation.
Module datasheet Voc, Vmp, Isc and Imp must share reference conditions. Ns counts modules per series string and Np counts identical parallel strings. The coefficient is entered as signed percent per degree Celsius. The other-string current is (Np − 1)Isc at the reference conditions, not a complete reverse-fault or fuse-sizing calculation.
Variables
Use sequence
From measurement to review
- Obtain one compatible module datasheet and define identical series and parallel counts.
- Enter reference electrical values, the signed relative Voc coefficient and the applicable cell temperatures.
- Review voltage limits, current corrections, reverse-current limits and protection with the applicable system design procedure.
Limits
What this calculation does not confirm
- Strings have identical matched modules and series counts; shading, mismatch, bypass action and operating-point variation are excluded.
- Cold Voc uses a linear manufacturer-coefficient model. Tolerance, irradiance effects and required design corrections need separate review.
- Other-string Isc is a reference-condition arithmetic sum. It is not a worst-case fault current, protective-device rating or approval of connectors, cables or inverters.
Calculator FAQ
Use the number without losing the engineering context.
These answers clarify what the tool calculates and where a product-specific review still begins.
Product selection support
Connect the calculation with cable-entry product options.
Bepto Cable Glands can help relate a preliminary result to the product family and current model information for your application. You can start with the details you have; a complete drawing package is not needed to ask a question.