Engineering Calculator · 115
Shielding Ratio & dB Converter
Convert a stated shielding reduction ratio to decibels, or decibels to a linear ratio, with an explicit amplitude or power basis.
Live calculation
Enter the known values.
Units remain visible beside every field and result. Change any input to recalculate immediately in your browser.
Results
The calculation runs locally in this browser. Values are not submitted or stored by this tool.
Direct answer
What this result means
For a reference-to-residual amplitude ratio R, attenuation is 20 log₁₀(R); for a power ratio it is 10 log₁₀(R). A 100:1 amplitude ratio is 40 dB, while a 100:1 power ratio is 20 dB. Choose the measured quantity and ratio direction before interpreting the result.
Formula & theory
Make the assumptions visible.
R is the reference quantity divided by the residual quantity, so attenuation is positive for R > 1. The same quantity basis applies to the residual percentage 100/R. The diagram shows a larger reference signal and a smaller residual signal; it does not predict shielding from braid coverage or gland geometry.
R is the reference quantity divided by the residual quantity, so attenuation is positive for R > 1. The same quantity basis applies to the residual percentage 100/R. The diagram shows a larger reference signal and a smaller residual signal; it does not predict shielding from braid coverage or gland geometry.
Variables
Use sequence
From measurement to review
- Identify field/amplitude or power as the measured quantity and confirm reference divided by residual.
- Choose the known ratio or dB value, then enter it on the matching basis.
- Retain frequency, test method, fixture and quantity basis with the converted result when comparing shielding measurements.
Limits
What this calculation does not confirm
- Compared quantities share a compatible measurement definition, frequency and fixture. For voltage-to-power equivalence, impedances must be equal.
- Screening attenuation uses the appropriate feeding-to-coupled power ratio defined by its test method; generic field shielding uses the corresponding field ratio.
- This converter does not calculate measured shielding, coupling loss, transfer impedance or standards compliance from an EMC gland or braid construction.
Calculator FAQ
Use the number without losing the engineering context.
These answers clarify what the tool calculates and where a product-specific review still begins.