Junction Boxes / Multi-way

F3 Multi-Way Junction Boxes

Two- to six-way junction boxes for joining cables or connecting several branches.

  • Cable entries: Two to six entries and their directions
  • Terminals: Circuit connections, conductor size and terminal method
  • Mounting: Box footprint, cover access and cable bend space
Product formsModel-specific constructions and connection layoutsModel sizesDimensions, connections and cable rangesApplication conditionsCable, mounting and environment vary by model

Junction-box groups

Boxes for cable joints, branches and switches.

F1 provides compact boxes, F2 a T junction, and F3 and F5 multi-way layouts. A separate enclosure holds a rocker switch.

F3 Multi-Way Junction Boxes range

Choose your f3 multi-way junction boxes

F3 boxes provide two- through six-way cable layouts. Choose the entry count for a straight joint or a distribution point with several branches.

Choose one product or compare the full group

Models & specifications

F3 Multi-Way Junction Boxes: specifications and dimensions

Select a product to see its specifications, drawings and sizes.

Product selection

Choose the F3 entry count and terminal layout.

Count every incoming and outgoing cable, then check the terminals for the required conductor connections.
  • 01Cable entries: Two to six entries and their directions
  • 02Terminals: Circuit connections, conductor size and terminal method
  • 03Mounting: Box footprint, cover access and cable bend space
F3 Multi-Way Junction Boxes

01 / Protected distribution

F3 Multi-Way Junction Boxes

F3 junction boxes provide two to six cable entries in a PA66 housing. The range uses screw or quick-connect terminals rated at 450 V / 32 A for 0.5–10 mm² conductors.

Product reference

Product group
F3 Multi-Way Junction Boxes
Application
A multi-cable junction needs a sealed enclosure with a 32 A terminal configuration.

Key specifications

Model options
F3-2T; F3-3T; F3-4T; F3-5T; F3-6T
Shell Material
Nylon PA66
Conductor Material
59-1 brass
O-Ring Material
Silicone

Product specifications

Construction and details

F3-6T 6-Way Junction Box — Enclosure layout and terminal options
F3-6T 6-Way Junction Box

Enclosure layout and terminal options

Use the current model instructions to confirm conductor preparation and terminal connections.

Read the marked dimensions with the current model drawing; do not infer sizes by measuring the illustration.

Model specification tables
Further specifications
IP Rating
IP68
Operating Temperature
-40°C to +105°C
Rated Voltage / Current
450 V / 32 A
Applicable Wire Size
0.5 – 10mm²
Termination
Screw Terminal or Quick-Connect Terminal
Housing flammability
UL94 V-0
Storage temperature
Room temperature
Dielectric withstand voltage
1,500 V
Key features
  • Two to six cable entriesF3-2T, F3-3T, F3-4T, F3-5T and F3-6T provide two to six cable-entry positions.
  • 32 A terminal configurationThe F3 electrical rating is 450 V / 32 A, with a 0.5–10 mm² conductor range.
  • Two terminal stylesScrew-terminal and quick-connect versions provide different conductor-clamping methods.

Model specification tables

Model sizes and specifications

Open a table to compare model sizes and connection details.
F3 Multi-Way Junction Boxes

F3 Multi-Way Junction Boxes

F3 Multi-Way Junction Boxes

Model specificationsF3 — order codes and cable sizes
ModelOrder codePack quantity (pcs)Cable entriesCable diameter range (mm)Weight (g)Carton weight (kg)
F3-2TMN-1412ways5-8163.226.6
F3-2TMN-1512ways9-12162.226.5
F3-2TMN-1612ways10-14161.226.4
F3-3TMN-1713ways5-816326.5
F3-3TMN-1813ways9-1216226.2
F3-4TMN-1914ways5-817024.1
F3-4TMN-2014ways9-1216923.8
F3-5TMN-2115ways5-818325.8
F3-5TMN-2215ways9-1218225
F3-6TMN-2316ways5-819527.3
F3-6TMN-2416ways9-1219426.8
F3-6TMN-2516ways10-1419326.3

Need help matching an existing part? Send us its model name or a photo.

Selection checks

Choose the right model

F3 boxes provide two- through six-way cable layouts. Choose the entry count for a straight joint or a distribution point with several branches.

  1. Cable entriesTwo to six entries and their directions
  2. TerminalsCircuit connections, conductor size and terminal method
  3. MountingBox footprint, cover access and cable bend space

Product support

Need a model recommendation or a quote?

Send a model name, a photo or a short question. We can help with product selection, samples and pricing. Share any of the details below that you already have.

Request product support
  • F3 model or wiring sketchSend an F3 model or a sketch showing the cables and branches you need.
  • Entry count and cable diametersTell us how many entries are needed and add the cable diameters if known.
  • Conductor sizes and currentInclude the sizes of the conductors that join and the current through those connections, if available.
  • Preferred terminal methodMention screw or quick-connect terminals if either suits your wiring process better.
  • Mounting spaceDescribe the mounting position and room for opening the cover and bending the cables.

F3 Multi-Way Junction Boxes FAQ

Product questions

Find answers about fit, wiring and product differences.

F3 Multi-Way Junction Boxes

01Does a six-way box have six electrical poles?

No. Ways describe the cable-entry layout here. The number of electrical connections depends on the terminal arrangement inside the box.

02Can an F3 box be used with fewer cables than entries?

Only with suitable closures for unused entries. Check the box instructions and the terminal layout for the intended wiring.

F3 Multi-Way Junction Boxes

F3 Multi-Way Junction Boxes

01Which F3 model has the cable entries I need?

The number before T gives the cable-entry count: F3-2T has two entries, through to F3-6T with six.

02What electrical rating and conductor range does F3 use?

F3 junction boxes are rated at 450 V / 32 A for 0.5–10 mm² conductors.

03Can I choose screw or quick-connect terminals for F3?

Yes. Both terminal styles are available in the F3 range.

04How do I choose an F3 order code?

Choose the cable-entry count first, then match each cable outside diameter to the seal range in that model table. The order code identifies the enclosure and seal combination.